IntroductionEarlier studies show that a Cochlear Implant (CI), capable of providing intracochlear electrical stimulation independent of environmental sounds, appears to suppress tinnitus at least for minutes. The current main objective is to compare the long-term suppressive effects of looped (i.e. repeated) electrical stimulation (without environmental sound perception) with the standard stimulation pattern of a CI (with environmental sound perception). This could open new possibilities for the development of a “Tinnitus Implant” (TI), an intracochlear pulse generator for the suppression of tinnitus.Materials and MethodsTen patients with single sided deafness suffering from unilateral tinnitus in the deaf ear are fitted with a CI (MED-EL Corporation, Innsbruck, Austria). Stimulation patterns are optimized for each individual patient, after which they are compared using a randomized crossover design, with a follow-up of six months, followed by a 3 month period using the modality of patient’s choice.ResultsResults show that tinnitus can be suppressed with intracochlear electrical stimulation independent of environmental sounds, even long term. No significant difference in tinnitus suppression was found between the standard clinical CI and the TI.ConclusionIt can be concluded that coding of environmental sounds is no requirement for tinnitus suppression with intracochlear electrical stimulation. It is therefore plausible that tinnitus suppression by CI is not solely caused by an attention shift from the tinnitus to environmental sounds. Both the standard clinical CI and the experimental TI are potential treatment options for tinnitus. These findings offer perspectives for a successful clinical application of the TI, possibly even in patients with significant residual hearing.Trial RegistrationTrialRegister.nl NTR3374
BackgroundOver the last years, less invasive surgical techniques with soft tissue preservation for bone conduction hearing implants (BCHI) have been introduced such as the linear incision technique combined with a punch. Results using this technique seem favorable in terms of rate of peri-abutment dermatitis (PAD), esthetics, and preservation of skin sensibility. Recently, a new standardized surgical technique for BCHI placement, the Minimally Invasive Ponto Surgery (MIPS) technique has been developed by Oticon Medical AB (Askim, Sweden). This technique aims to standardize surgery by using a novel surgical instrumentation kit and minimize soft tissue trauma.MethodsA multicenter randomized controlled trial is designed to compare the MIPS technique to the linear incision technique with soft tissue preservation. The primary investigation center is Maastricht University Medical Center. Sixty-two participants will be included with a 2-year follow-up period. Parameters are introduced to quantify factors such as loss of skin sensibility, dehiscence of the skin next to the abutment, skin overgrowth, and cosmetic results. A new type of sampling method is incorporated to aid in the estimation of complications. To gain further understanding of PAD, swabs and skin biopsies are collected during follow-up visits for evaluation of the bacterial profile and inflammatory cytokine expression.The primary objective of the study is to compare the incidence of PAD during the first 3 months after BCHI placement. Secondary objectives include the assessment of parameters related to surgery, wound healing, pain, loss of sensibility of the skin around the implant, implant extrusion rate, implant stability measurements, dehiscence of the skin next to the abutment, and esthetic appeal. Tertiary objectives include assessment of other factors related to PAD and a health economic evaluation.DiscussionThis is the first trial to compare the recently developed MIPS technique to the linear incision technique with soft tissue preservation for BCHI surgery. Newly introduced parameters and sampling method will aid in the prediction of results and complications after BCHI placement.Trial registrationRegistered at the CCMO register in the Netherlands on 24 November 2014: NL50072.068.14. Retrospectively registered on 21 April 2015 at ClinicalTrials.gov: NCT02438618. This trial is sponsored by Oticon Medical AB.Electronic supplementary materialThe online version of this article (doi:10.1186/s13063-016-1662-0) contains supplementary material, which is available to authorized users.
Objective: Comparing the surgical outcomes of the Minimally Invasive Ponto Surgery (MIPS) technique with the linear incision technique with soft tissue preservation (LITT-P) for bone conduction devices after a follow-up of 22 months.Methods: In this multicenter randomized controlled trial, there was the inclusion of 64 adult patients eligible for unilateral surgery. There was 1:1 randomization to the MIPS (test) or the LITT-P (control) group. The primary outcome was an (adverse) soft tissue reaction. Secondary outcomes were pain, loss of sensibility, soft tissue height/overgrowth, skin sagging, implant loss, Implant Stability Quotient measurements, cosmetic scores, and quality of life questionnaires.Results: Sixty-three subjects were analyzed in the intention-to-treat population. No differences were found in the presence of (adverse) soft tissue reactions during complete follow-up. Also, there were no differences in pain, wound dehiscence, skin level, soft tissue overgrowth, and overall quality of life. Loss of sensibility (until 3-month post-surgery), cosmetic scores, and skin sagging outcomes were better in the MIPS group. The Implant Stability Quotient was higher after the LITT-P for different abutment lengths at various points of follow-up. Implant extrusion was nonsignificantly higher after the MIPS (15.2%) compared with LITT-P (3.3%).Conclusion: The long-term results show favorable outcomes for both techniques. The MIPS is a promising technique with some benefits over the LITT-P. Concerns regarding nonsignificantly higher implant loss may be overcome with future developments and research.Clinical Trial Registration:www.ClinicalTrials.gov, identifier: NCT02438618.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.