We confirmed that post-stroke UI is a predictor of greater mortality at 1 week, 6 months and 12 months after stroke. However, patients who regain normal bladder control in the first week have a comparable prognosis as the patients who do not have micturition disturbances following stroke.
BackgroundTo evaluate the long-term effectiveness and safety of a new Double BioDisk (DBD) device for closure of atrial septal defect (ASD).Materials and methods.ASD was created with transeptal needle (TS) followed by balloon dilatation in 12 sheep weighing 40.1 to 64 kg (mean 55.2 ± 7.1). The ASD diameters were measured after creation and two weeks later before DBD implantation. The DBDs consists of two nitinol rings 18 to 28 mm in diameter connected with small cannulas and covered with a porcine small intestinal submucosa (SIS). They were implanted via a 10 Fr sheath. DBD effectiveness was evaluated by angiocardiography and by intra-cardiac echogram (ICE) with Doppler studies. Two animals were acute, two were followed for 6 weeks, three for 3 months, three for 6 months and two for 12 months.ResultsTS punctures were successful in 10 sheep. In two sheep ASD was created by existing PFO dilation. The ASD size ranged from 13–15 mm (mean 14.1± 0.73 mm) after initial balloon dilation and from 9–13 mm (mean 10.06 ± 1.37 mm) after two weeks. In all animals none of the successfully implanted DBDs spontaneously embolized on release or on follow up. ICE demonstrated no shunting around the DBDs during follows ups. Macroscopic and histologic evaluation of the 6, 12, 24 and 52 weeks animals showed that DBDs were well incorporated in the atrial septum with complete shunt closure. The SIS showed progressive remodeling with the host cells, including endothelization of the DBD devices.ConclusionsASD closure with the Double BioDisk is safe and effective in adult sheep.
BackgroundMost of the presently used percutaneous arterial closure devices (PACD) for hemostasis after interventional vascular procedures are effective, but carry risk of complications by deposition of a foreign body. A new promising externally applied PACD – chitosan-based HemCon Bandage (HCB) was explored in sheep. The HCB hemostatic efficacy and complications occurring with its use were compared to those with the standard manual compression (SMC).Material and methodsBoth superficial femoral arteries (SFA) of 9 heparinized sheep were catheterized with an 8F sheath for 5 minutes. After the sheath withdrawal, hemostasis with the HCB was compared with hemostasis achieved with SMC in the contralateral SFA. Iliac angiograms performed by carotid artery approach determined the hemostasis time.ResultsThe HCB use shortened time to hemostasis with a mean time of 6.9 ± 3.9 minutes versus 10.8 ± 2.8 minutes for the SMC (P-value 0.019). Seven SFAs in the HCB group and only 1 SFA in the SMC group exhibited hemostasis in 5 minutes. All nine SFAs using the HCB showed femoral artery patency and demonstrated less hematoma (2/9) than in the SMC group (8/9). No complications developed in the HCB group, one SFA occlusion was seen in the SMC group.ConclusionsThe externally applied HCB in heparinized sheep was safe and effective. It significantly shortened time to hemostasis at the SFA access sites following 8F sheath removal. Proper application of the HCB was necessary to shorten hemostasis and prevent hematoma formation. The HCB should be tested in a clinically controlled study to evaluate its efficacy in humans.
The study showed a high recanalization rate with improved clinical outcome and a low rate of periprocedural complications in our stroke patients treated with mechanical revascularization. Therefore, we could conclude that endovascular revascularization (primary or in combination with a bridging thrombolysis) was an effective and safe procedure for intracranial large vessel recanalization in acute stroke.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.