BackgroundRadiological outcomes between anterior and posterior approach in Lenke 5C curves were still controversial. Meta-analysis on published articles to compare fusion segments and radiological outcomes between the two surgical approaches was performed.MethodsElectronic database was conducted for searching studies concerning the anterior versus posterior approach in Lenke 5C curves. After quality assessment, data of means, standard deviations, and sample sizes were extracted. RevMan 5.3 was adopted for data analysis.ResultsSeven case-control studies involving 308 Lenke 5C AIS patients were identified in the meta-analysis. No significant differences were noted in correction rate of thoracolumbar/lumbar curve (95 % CI −6.02 to 4.32, P = 0.75) and incidence of proximal junctional kyphosis (95 % CI 0.12 to 7.19, P = 0.94) of final follow-up, in change values of thoracolumbar/lumbar curve (95 % CI −3.28 to 7.19, P = 0.46) and thoracic kyphosis (95 % CI −4.10 to 0.13, P = 0.07). The anterior approach represented a significant shorter fusion segments compared to posterior approach (95 % CI −1.72 to −0.71, P < 0.00001). The posterior approach obtained a larger increasing Cobb angle of lumbar lordosis than the anterior approach (95 % CI −6.06 to −0.61, P = 0.02).ConclusionsThe anterior and posterior approach can obtain comparable coronal correction, change values of thoracic kyphosis, and incidence of proximal junctional kyphosis. The anterior approach saves approximate one more fusion segment, and the posterior approach can obtain a larger increasing Cobb angle of lumbar lordosis, from preoperation to final follow-up.Trial registrationThe article type of this study is meta-analysis and prospective registration is not required.
BackgroundThe correlation between implant density and deformity correction has not yet led to a precise conclusion in adolescent idiopathic scoliosis (AIS). The aim of this study was to evaluate the effects of low density (LD) and high density (HD) pedicle screw instrumentation in terms of the clinical, radiological and Scoliosis Research Society (SRS)-22 outcomes in Lenke 1 AIS.MethodsWe retrospectively reviewed 62 consecutive Lenke 1 AIS patients who underwent posterior spinal arthrodesis using all-pedicle screw instrumentation with a minimum follow-up of 24 months. The implant density was defined as the number of screws per spinal level fused. Patients were then divided into two groups according to the average implant density for the entire study. The LD group (n = 28) had fewer than 1.61 screws per level, while the HD group (n = 34) had more than 1.61 screws per level. The radiographs were analysed preoperatively, postoperatively and at final follow-up. The perioperative and SRS-22 outcomes were also assessed. Independent sample t tests were used between the two groups.ResultsComparisons between the two groups showed no significant differences in the correction of the main thoracic curve and thoracic kyphosis, blood transfusion, hospital stay, and SRS-22 scores. Compared with the HD group, there was a decreased operating time (278.4 vs. 331.0 min, p = 0.004) and decreased blood loss (823.6 vs. 1010.9 ml, p = 0.048), pedicle screws needed (15.1 vs. 19.6, p < 0.001), and implant costs ($10,191.0 vs. $13,577.3, p = 0.003) in the LD group.ConclusionsBoth low density and high density pedicle screw instrumentation achieved satisfactory deformity correction in Lenke 1 AIS patients. However, the operating time and blood loss were reduced, and the implant costs were decreased with the use of low screw density constructs.
Naringenin (NAR) is a natural predominant flavanone and has a wide range of pharmacological activities. The aim of this study was to investigate the protective mechanisms of NAR on RANKL-induced osteoclastogenesis and osteoclast bone resorption. T cells were divided into four groups under different concentrations of NAR (0, 25, 50, 100 µM). CD4 T cell subsets in different groups were evaluated by flow cytometry. TRAP staining, pit formation assays and F-actin ring immunofluorescent staining were performed. In addition, gene expression of osteoclast-specific markers was analyzed by qPCR and Western blot. Our results showed that compared with the control group, there were relatively fewer Th1 and Th17 cells and more Th2 cells and Treg cells in the NAR groups. Besides, the number of TRAP-positive multinucleated osteoclasts, the areas of bone resorption pits and the size and number of F-actin rings were notably decreased in the bone marrow macrophages (BMMs) treated with T-cell supernatant containing NAR. Moreover, NAR treatment dramatically reduced the expressions of cathepsin K, c-Fos, DC-STAMP, NFATc1, TRAP, and V-ATPase d2 at mRNA and protein levels. However, these effects were abolished by adding a neutralizing antibody against IL-4. In conclusion, NAR suppressed RANKL-induced osteoclastogenesis and osteoclast bone resorption by promoting the release of IL-4 from T cells.
Background Bone defects remain an unsolved clinical problem due to the lack of effective osteogenic induction protocols. Nanomaterials play an important role in bone defect repair by stimulating osteogenesis. However, constructing an effective bioactive nanomaterial remains a substantial challenge. Methods In this study, mesoporous silica nanoparticles (MSNs) were prepared and used as nanocarriers for basic fibroblast growth factor (bFGF). The characteristics and biological properties of the synthetic bFGF@MSNs were tested. The osteogenic effects of the particles on the behavior of MC3T3-E1 cells were investigated in vitro. In addition, the differentially expressed genes during induction of osteogenesis were analyzed by transcriptomic sequencing. Radiological and histological observations were carried out to determine bone regeneration capability in a distal femur defect model. Results Achieving bFGF sustained release, bFGF@MSNs had uniform spherical morphology and good biocompatibility. In vitro osteogenesis induction experiments showed that bFGF@MSNs exhibited excellent osteogenesis performance, with upregulation of osteogenesis-related genes (RUNX2, OCN, Osterix, ALP). Transcriptomic sequencing revealed that the Wnt/β-catenin signalling pathway could be activated in regulation of biological processes. In vivo, bone defect repair experiments showed enhanced bone regeneration, as indicated by radiological and histological analysis, after the application of bFGF@MSNs. Conclusion bFGF@MSNs can promote bone regeneration by activating the Wnt/β-catenin signalling pathway. These particles are expected to become a potential therapeutic bioactive material for clinical application in repairing bone defects in the future.
Background:Incidence of complications and reoperations between pedicle screw (PS) and hybrid instrumentations (HI) are still controversial in adolescent idiopathic scoliosis (AIS) patients. A systematic review and meta-analysis were performed to compare overall complications, reoperations, and radiographic outcomes between the 2 constructs.Methods:Strictly followed the PRISMA 2009 guidelines, the MEDLINE, EMBASE, and the Cochrane Library databases were used to search for literatures up to April 2016, addressing PS versus HI in AIS patients. The Newcastle–Ottawa scale was adopted to assess the quality of the studies. Data on complications, reoperations, Cobb angle of major curve, thoracic kyphosis, and proximal junctional measurement were extracted from the included studies. RevMan 5.3 and SPSS 21.0 were used for statistical analysis.Results:Twenty-four case-control studies with a total of 3042 AIS patients (1582 PS, 1460 HI) were included, consisting of 1 randomized controlled trial, 1 prospective study, and 22 retrospective studies. Decreased overall complications (95% CI 0.42–0.87, P = .007; I2 = 38%) and reoperations (95% CI 0.22–0.62, P = .0001; I2 = 0%) were found in PS group compared with HI group. As regard to reasons for reoperations, increased incidence of pseudarthrosis (P = .005), dislodged instrumentation (P = .005), and deep infection (P = .016) occurred in HI group. PS group achieved a better coronal correction (95% CI −7.06 to −4.54, P < .00001; I2 = 34%), but HI group was more powerful in restoring thoracic kyphosis (95% CI −7.88 to −3.70, P < .00001; I2 = 60%), and no significant differences were found in proximal junctional measurement (95% CI −0.88 to 1.54, P = .59; I2 = 0%) between the 2 constructs.Conclusion:Compared with hybrid instrumentation, pedicle screw construct provides better coronal correction but less thoracic kyphosis restoring, with decreased incidence of overall complications and reoperations in AIS patients. As regard to the pedicle screw construct, the most common reasons for reoperation are malposition, deep infection, pseudarthrosis, and prominent implant.
BackgroundPrevious studies have reported that rod composition and diameter, as well as the correction technique are key factors associated with thoracic kyphosis (TK) restoration. However, few study has analyzed the correlation between screw density and TK restoration in hypokyphotic adolescent idiopathic scoliosis (AIS).MethodsFifty-seven thoracic AIS patients with preoperative TK < 10° treated with all pedicle screw fixation with a minimum 2-year follow-up were recruited. Preoperative and postoperative radiographic measurements, and information of posterior instrumentation were reviewed. Pearson and Spearman correlation coefficient analysis were used to assess relationships between change in TK and number of variables. Then, the included patients were classified into two groups (Group 1: postoperative TK ≥ 20°; Group 2: postoperative TK < 20°) to evaluate the influence factors of TK restoration.ResultsThe average preoperative TK was 4.75°, which was significantly restored to 17.30° (P < 0.001). Significant correlations were found between change in TK and flexibility of major thoracic curve (r = 0.357, P = 0.006), preoperative TK (r = −0.408, P = 0.002), and screw density of concave side (r = 0.306, P = 0.021), respectively. In the subgroup comparison, 17 patients (29.8%) maintain the postoperative TK ≥ 20°, increased flexibility of major thoracic curve (P < 0.001), screw number of concave side (P = 0. 029), and cobalt chromium rods (P = 0.041) were found in the group of postoperative TK ≥ 20°.ConclusionsTK restoration remains a challenge for AIS patients with hypokyphosis, especially for the poor flexibility ones. Except for thicker and cobalt chromium rods, screw density of concave side might be another positive predictor of restoring normal kyphosis, which provides a stronger corrective force on the sagittal plane with more pedicle screws.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.