Background: The aim of this study was to investigate factors determining postoperative courses, especially focusing on the rebound phenomenon, in adolescent patients with idiopathic genu valgum who underwent temporary hemiepiphysiodesis and implant removal. Methods: We identified and reviewed patients with idiopathic genu valgum treated with temporary hemiepiphysiodesis [using tension-band plates (plate group, PG) or transphyseal screws (screw group, SG)] and followed-up to skeletal maturity. Results: In our cohort [68 patients and their 68 limbs (randomly selected in bilateral cases)], the mean hip-knee-ankle alignment was -5.4 ± 1.8 degrees at the time of temporary hemiepiphysiodesis (negative means valgus), 2.6 ± 2.1 degrees at the time of implant removal, and 0.7 ± 2.6 degrees at the last followup, respectively. Regarding the implants, the correction speed was not significantly different (P = 0.192-0.315) between the PG (total 1.29 ± 0.37 degrees/mo, 0.71 ± 0.23 degrees/mo at distal femur, 0.59 ± 0.16 degrees/mo at proximal tibia, n = 19) and the SG (total 1.22 ± 0.49 degrees/mo, 0.65 ± 0.25 degrees/mo at distal femur, 0.57 ± 0.23 degrees/mo at proximal tibia, n = 49). The magnitude of rebound phenomenon in the PG (4.1 ± 1.9 degrees) was greater (P < 0.001) than that in the SG (1.1 ± 3.1 degrees). The use of plates and faster correction speed, rather than more severe preoperative deformity or greater correction angle, were positively associated with the rebound phenomenon in regression analyses. Among the 68 knees, 1 showed valgus alignment ≥ 5 degrees and 5 showed varus alignment ≥ 5 degrees at the last follow-up. All the 6 cases were observed in the SG. Surgical wound dehiscence was observed in 1 patient in the PG. Conclusions: The use of plates and faster correction speed were positively associated with the rebound phenomenon. Careful attention will be needed with the corresponding conditions for optimal results. Progressive genu varum after transphyseal screw removal, which was observed in this study, should be explored in future research.
Reverse shoulder arthroplasty is an ideal treatment for glenohumeral dysfunction due to cuff tear arthropathy. As the number of patients treated with reverse shoulder arthroplasty is increasing, the incidence of complications after this procedure also is increasing. The rate of complications in reverse shoulder arthroplasty was reported to be 15%–24%. Recently, the following complications have been reported in order of frequency: periprosthetic infection, dislocation, periprosthetic fracture, neurologic injury, scapular notching, acromion or scapular spine fracture, and aseptic loosening of prosthesis. However, the overall complication rate has varied across studies because of different prosthesis used, improvement of implant and surgical skills, and different definitions of complications. Some authors included complications that affect the clinical outcomes of the surgery, while others reported minor complications that do not affect the clinical outcomes such as minor reversible neurologic deficit or minimal scapular notching. This review article summarizes the processes related to diagnosis and treatment of complications after reverse shoulder arthroplasty with the aim of helping clinicians reduce complications and perform appropriate procedures if/when complications occur.
Background: After posterior cruciate ligament injury, stress radiography is a common method of quantifying posterior instability, defined as the side-to-side difference in posterior tibial displacement (PTD) between the injured knee and contralateral noninjured knee. However, no study has evaluated the reliability of PTD according to knee flexion angle (KFA) measurements on stress radiographs. Purpose: To evaluate the test-retest reliability of stress radiographic measurements of the KFA in the noninjured knee. In addition, we established a reliable range of KFAs to indicate posterior instability by comparing results with the instability measured at 90° KFA, which is considered the gold standard. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: We evaluated patients who had undergone bilateral stress radiographic examinations at least 5 times for ligament injuries between January 2013 and November 2019. All examinations were performed on a Telos device with a 150-N posterior load. A total of 120 knees and 644 stress radiographs were enrolled. We measured the KFA and PTD on stress radiographs and evaluated the reliability of repeated PTD measurement and the correlation between KFA and PTD. Results: The distribution of the actual noninjured knee KFA ranged from 56.9° to 106.7°. Among the 644 radiographs, 155 (24.1%) showed KFAs between 85° and 95°, and 287 (44.6%) showed KFAs between 80° and 85°. A significant correlation was found between KFA and PTD ( P < .001), and the intrapatient intraclass correlation coefficient (ICC) was 0.788. A KFA range of 85° to 92° satisfied the criteria of high ICC (0.885) and nonsignificant correlation between KFA and PTD ( P = .055) and thus was considered a reliable range of KFAs for quantifying posterior instability. We found no significant risk factors for measurement error, including age ( P = .674), sex ( P = .328), height ( P = .957), weight ( P = .248), or body mass index ( P = .257). Conclusion: We found high reproducibility of posterior displacement measurements on Telos stress radiography at a KFA of 85° to 92° in noninjured knees.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.