Accurate stent graft implantation in the distal LZ with the currently available deployment mechanism is often challenging. An inaccurate landing is associated with a higher incidence of endoleak Ib.
ObjectiveManagement of thoracic aortic aneurysms (TAAs) comprises regular diameter follow-up until the indication criterion for prophylactic surgery is reached. However, this approach is unable to predict the majority of acute type A aortic dissections (ATAADs). The current study aims to evaluate the diagnostic accuracy of ascending aortic diameter, length and volume for occurrence of ATAAD.MethodsThis two-centre observational cohort study retrospectively screened 477 consecutive patients who presented with ATAAD between 2009 and 2018. Of those, 25 (5.2%) underwent CT angiography (CTA) within 2 years before dissection onset. Aortic diameter, length and volume of these patients (‘pre-ATAAD’) were compared with those of TAA controls (n=75). Receiver operating curve analysis was performed to evaluate the predictive accuracy of the three different measurements.Results96% of patients with pre-ATAAD did not meet the surgical diameter threshold of 55 mm before dissection onset. Maximal aortic diameters (45 (40–49) mm vs 46 (44–49) mm, p=0.075) and volume (126 (95–157) cm3 vs 124 (102–136) cm3, p=0.909) were comparable between patients with pre-ATAAD and TAA controls. Conversely, ascending aortic length (84±9 mm vs 90±16 mm, p=0.031) was significantly larger in patients with pre-ATAAD. All three parameters had an area under the curve of >0.800. At the 55 mm cut-off point, the maximal diameter yielded a positive predictive value (PPV) of 20%. While maintaining same specificity levels, measurements of aortic volume and length showed superior diagnostic accuracy (PPV 55% and 70%, respectively).ConclusionMeasurements of aortic volume and length have superior diagnostic accuracy compared with the maximal diameter and could improve the timely identification of patients at risk for ATAAD.
BackgroundThe stress in the ascending aorta results from many biomechanical factors including the geometry of the vessel and its maximum dimensions, arterial blood pressure and longitudinal systolic stretching due to heart motion. The stretching of the ascending aorta resulting from the longitudinal displacement of the aortic annulus during the heart cycle has not been examined in the general population so far. The aim of the study is to evaluate this parameter using cardiovascular magnetic resonance (CMR) imaging in the general population in all age groups.MethodsThe cardiac magnetic resonance images of 73 patients were evaluated. The maximum distance to which the ventriculo-aortic junction was pulled by the contracting heart (LDAA – longitudinal displacement of the aortic annulus) was measured in the cine coronal sequences. Moreover, the maximum dimensions of the aortic root and the ascending aorta were assessed.ResultsThe LDAA value was on average 11.6 ± 2.9 mm (range: 3-19 mm; 95% CI: 10.9–12.3 mm) and did not differ between males and females (11.8 ± 2.9 mm vs. 11.2 ± 2.9 mm, p = .408). The diameter of the ascending aorta was 32 ± 6.3 mm (range: 20-57 mm). The maximal dimension of the aortic root was 35 ± 5.1 mm (range: 18-42 mm). There was a statistically significant negative correlation between the LDAA and the age of patients (r = −.38, p = .001). There was no significant correlation between the LDAA and aortic root dimension (r = .1, p = .409) and between the LDAA and diameter of the ascending aorta (r = .16, p = .170).ConclusionsHuman aortic root and ascending aorta are significantly stretched during systole and the distance to which the aorta is stretched decreases with age. The measurement of the longitudinal displacement of the aortic annulus using the CMR is feasible and reproducible.
Patients and MethodsPerioperative data on 176 consecutive patients (128 men, 72.7%) undergoing TEVAR with complete overstenting of the LSA for acute and chronic thoracic aortic disease at the Leipzig Heart Center, the Heart Center Freiburg
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.