The paper presents the results of experimental research in which the flat specimens have been tested under tensile loading. The specimens are made of nodular cast iron. The experiments are performed under two different deformation rates using standard specimens. Displacement and temperature distribution on the surfaces of the specimens, during experiment, are determined using the optical measuring system ARAMIS 4M (digital image correlation system), thermocouples and infrared thermography. The goal of the research was to find correlation between the elastic deformations and increase of the surface temperatures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.