Pupillometry data are commonly reported relative to a baseline value recorded in a controlled pre-task condition. In this study, the influence of the experimental design and the preparatory processing related to task difficulty on the baseline pupil size was investigated during a speech intelligibility in noise paradigm. Furthermore, the relationship between the baseline pupil size and the temporal dynamics of the pupil response was assessed. The analysis revealed strong effects of block presentation order, within-block sentence order and task difficulty on the baseline values. An interaction between signal-to-noise ratio and block order was found, indicating that baseline values reflect listener expectations arising from the order in which the different blocks were presented. Furthermore, the baseline pupil size was found to affect the slope, delay and curvature of the pupillary response as well as the peak pupil dilation. This suggests that baseline correction might be sufficient when reporting pupillometry results in terms of mean pupil dilation only, but not when a more complex characterization of the temporal dynamics of the response is considered. By clarifying which factors affect baseline pupil size and how baseline values interact with the task-evoked response, the results from the present study can contribute to a better interpretation of the pupillary response as a marker of cognitive processing.
Recordings of the pupillary response have been used in numerous studies to assess listening effort during a speech-in-noise task. Most studies focused on averaged responses across listeners, whereas less is known about pupil dilation as an indicator of the individuals’ listening effort. The present study investigated the reliability of several pupil features as potential indicators of individual listening effort and the impact of different normalization procedures on the reliability. The pupil diameters of 31 normal-hearing listeners were recorded during multiple visits while performing a speech-in-noise task. The signal-to-noise ratios (SNRs) of the stimuli ranged from [Formula: see text]12 dB to [Formula: see text]4 dB. All listeners were measured twice at separate visits, and 11 were re-tested at a third visit. To examine the reliability of the pupil responses across visits, the intraclass correlation coefficient was applied to the peak and mean pupil dilation and to the temporal features of the pupil response, extracted using growth curve analysis. The reliability of the pupillary response was assessed in relation to SNR and different normalization procedures over multiple visits. The most reliable pupil features were the traditional mean and peak pupil dilation. The highest reliability results were obtained when the data were baseline-corrected and normalized to the individual pupil response range across all visits. Moreover, the present study results showed only a minor impact of the SNR and the number of visits on the reliability of the pupil response. Overall, the results may provide an important basis for developing a standardized test for pupillometry in the clinic.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.