To analyze the impact of the coronavirus disease 2019 (COVID-19) outbreak during the first pandemic year in a single country. MethodsA cross-sectional study was designed. The free access database of the Chilean Department of Statistics and Health Information (DEIS) was used to compare the number of orthopedic procedures between 2019 and 2020. Country mobility was exported from the Institute of Complex Engineering Systems (ISCI) free-access database; this corresponds to a direct measurement of the degree of confinement of the country. Spearman correlation (rho) was used to analyze the total monthly COVID infection trend and mobility to orthopedics procedures. ResultsThe number of orthopedic surgeries fell by 22.8% during the first year of the pandemic. All surgical procedures were adversely affected, with the fracture/trauma surgeries being the least affected. The maximum adverse impact was seen in knee arthroplasty (-64%), followed by hip arthroplasty (-41%) and knee ligament reconstruction (-44%). The number of orthopedic procedures had a mild correlation to the monthly number of COVID-19 cases (rho=-0.53, p=0.08) and a strong correlation with the country's mobility (rho=0.94, p=0.0001). ConclusionsThe COVID-19 outbreak diminished the number of orthopedic procedures during 2020, and the impact was directly correlated to the country's mobility. The public health network did have a more significant adverse impact in elective surgeries due to a slower recovery than private institutions. An increase in the waiting list should be expected, which will widen the difference in access to orthopedic surgery in Chile.
The purpose of this study was to compare the efficacy of periarticular infiltration of gonyautoxin 2/3 (GTX 2/3) and a mixture of levobupivacaine, ketorolac, and epinephrine for pain management after total knee arthroplasty (TKA). Forty-eight patients were randomly allocated to receive periarticular infiltration of 40 µg GTX 2/3 (n = 24) diluted in 30 mL of sodium chloride 0.9% (study group) or a combination of 300 mg of levobupivacaine, 1 mg of epinephrine, and 60 mg ketorolac (n = 24) diluted in 150 mL of sodium chloride 0.9% (control group). Intraoperative anesthetic and surgical techniques were identical for both groups. Postoperatively, all patients received patient-controlled analgesia (morphine bolus of 1 mg; lockout interval of 8 minutes), acetaminophen, and ketoprofen for 72 hours. A blinded investigator recorded morphine consumption, which was the primary outcome. Also, the range of motion (ROM) and static and dynamic pain were assessed at 6, 12, 36, and 60 hours after surgery. The incidence of adverse events, time to readiness for discharge, and length of hospital stay were also recorded. The median of total cumulative morphine consumption was 16 mg (range, 0–62 mg) in the GTX 2/3 group and 9 mg (range, 0–54 mg) in control group, which did not reach statistical difference (median test, p = 0.40). Furthermore, static and dynamic pain scores were similar at all time intervals. GTX 2/3 was inferior in range of motion at 6 and 12 hours; nevertheless, we noted no difference after 36 hours. No differences between groups were found in terms of complications, side effects, or length of hospital stay. No significant differences were found between groups in terms of breakthrough morphine requirement. However, local anesthetic use resulted in an increased ROM in the first 12 hours. This prospective randomized clinical trial shows that GTX 2/3 is a safe and efficient drug for pain control after TKA; nevertheless, more studies using GTX 2/3 with larger populations are needed to confirm the safety profile and efficiency. This is level 1 therapeutic study, randomized, double-blind clinical trial.
Surgical techniques are learned gradually throughout an orthopedic residency. Training on real patients carries drawbacks such as limited access and elevated risk. Alternatively, surgical simulation allows residents to practice in a safe environment with greater access to standardized surgical tasks. Virtual reality simulators display images inside an artificial joint, often providing real-time haptic feedback to allow for realistic interaction. The objective of this study was to evaluate the construct validity of a virtual reality simulator for knee arthroscopy by analyzing the capacity of system parameters to distinguish between expert and novice surgeons. DesignThis comparative cross-sectional study contrasts the automated performance reports for novice and expert orthopedic surgeons after executing surgical tasks on the ARTHRO Mentor virtual reality simulator.
This study aims to correlate the tibial tubercle to trochlear groove (TT-TG) distance with knee axial alignment. The hypothesis is that as internal torsion of the distal femur or external torsion of the proximal tibial increases, the TT-TG distance increases. We designed a cross-sectional study approved by our institutional ethics review board. We reviewed 32 computed tomography angiographies of patients that have nonjoint or bone-related symptoms. Distal femoral torsion, proximal tibial torsion, knee articular torsion (AT), and TT-TG distance were measured. A regression analysis between the TT-TG distance and the AT was performed. A positive correlation between the TT-TG distance and the AT was found. An increase in external torsion of the proximal tibial or an increase in internal torsion of the distal femur increases the TT-TG distance. For a correct interpretation of the TT to trochlear groove distance, we propose that the axial alignment should be included in the regular analysis of patellofemoral disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.