Mantle cell lymphoma (MCL) is an aggressive lymphoma subtype with poor prognosis in which 18F-FDG-PET/CT role in treatment response evaluation and prediction of outcome is still unclear. The aim of this multicentric study was to investigate the role of 18F-FDG-PET/CT in staging MCL and the prognostic role of Deauville criteria (DC) in terms of progression-free survival (PFS) and overall survival (OS). We retrospectively enrolled 229 patients who underwent baseline and end-of-treatment (eot) 18F-FDG-PET/CT after first-line therapy. EotPET/CT scans were visually interpreted according to DC. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of PET/CT for evaluation of bone marrow (BM) were 27%, 100%, 100%, 48% and 57%, respectively. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy of PET/CT for evaluation of the gastrointestinal (GI) tract were 60%, 99%, 93%, 90% and 91%, respectively. At a median follow-up of 40 months, relapse occurred in 104 cases and death in 49. EotPET/CT results using DC significantly correlated with PFS, not with OS. Instead, considering OS, only MIPI score was significantly correlated. In conclusion, we demonstrated that MCL is an FDG-avid lymphoma and 18F-FDG-PET/CT is a useful tool for staging purpose, showing good specificity for BM and GI evaluation, but suboptimal sensitivity. EotPET/CT result was the only independent significant prognostic factor that correlated with PFS.
Background The early differential diagnosis among neurodegenerative parkinsonian disorders becomes essential to set up the correct clinical-therapeutic approach. The increased utilization of [18F] fluoro-deoxy-glucose positron emission tomography (FDG PET) and the pressure for cost-effectiveness request a systematic evaluation and a validation of its utility in clinical practice. This retrospective study aims to consider the contribution, in terms of increasing accuracy and increasing diagnostic confidence, of voxel-based FDG PET analyses in the differential diagnosis of these disorders, including Parkinson’s disease, multiple system atrophy, progressive supranuclear palsy, and cortico-basal syndrome. Method Eighty-three subjects with a clinically confirmed diagnosis of degenerative parkinsonian disorders who underwent FDG brain PET/CT were selected. A voxel-based analysis was set up using statistical parametric mapping (SPM) on MATLAB to produce maps of brain hypometabolism and relative hypermetabolism. Four nuclear physicians (two expert and two not expert), blinded to the patients’ symptoms, other physicians’ evaluations, and final clinical diagnosis, independently evaluated all data by visual assessment and by adopting metabolic maps. Results In not-expert evaluators, the support of both hypometabolism and hypermetabolism maps results in a significant increase in diagnostic accuracy as well as clinical confidence. In expert evaluators, the increase in accuracy and in diagnostic confidence is mainly supported by hypometabolism maps alone. Conclusions In this study, we demonstrated the additional value of combining voxel-based analyses with qualitative assessment of brain PET images. Moreover, maps of relative hypermetabolism can also make their contribution in clinical practice, particularly for less experienced evaluators.
Background: 18F-fluorodeoxyglucose (18F-FDG) positron-emission-tomography (PET) allows detection of cerebral metabolic alterations in neurological diseases vs. normal aging. We assess age- and sex-related brain metabolic changes in healthy subjects, exploring impact of activity normalization methods. Methods: brain scans of Italian Association of Nuclear Medicine normative database (151 subjects, 67 Males, 84 Females, aged 20–84) were selected. Global mean, white matter, and pons activity were explored as normalization reference. We performed voxel-based and ROI analyses using SPM12 and IBM-SPSS software. Results: SPM proved a negative correlation between age and brain glucose metabolism involving frontal lobes, anterior-cingulate and insular cortices bilaterally. Narrower clusters were detected in lateral parietal lobes, precuneus, temporal pole and medial areas bilaterally. Normalizing on pons activity, we found a more significant negative correlation and no positive one. ROIs analysis confirmed SPM results. Moreover, a significant age × sex interaction effect was revealed, with worse metabolic reduction in posterior-cingulate cortices in females than males, especially in post-menopausal age. Conclusions: this study demonstrated an age-related metabolic reduction in frontal lobes and in some parieto-temporal areas more evident in females. Results suggested pons as the most appropriate normalization reference. Knowledge of age- and sex-related cerebral metabolic changes is critical to correctly interpreting brain 18F-FDG PET imaging.
Background When faced with a painful knee replacement, ruling out infection is mandatory to set the correct therapeutic approach. However, it is not always easy, especially in subclinical/chronic infections. A multidisciplinary approach is necessary to assess in the most correct way each case of suspected periprosthetic knee joint infection. This review explores the role of nuclear medicine investigations in the management of periprosthetic knee infections and their proper use within a multidisciplinary pathway. Methods A PubMed search was conducted selecting studies from the past 10 years. Results Triphasic bone scintigraphy has high sensitivity (93%) but poor specificity (56%) for periprosthetic joint infections of the knee, with a high negative predictive value (NPV), ranging from 96% to 100%. Consequently, a negative bone scan is useful in ruling out infection. In contrast, radiolabeled leukocyte scintigraphy is characterized by a sensitivity of 85.7-93%, specificity of 93.6-100%, diagnostic accuracy of 92.6-98%, NPV of 93-97.8%, and positive predictive value (PPV) of 66.7-100%. By adding a tomographic acquisition with hybrid single-photon emission computed tomography combined with computed tomography technique (SPECT/CT), the diagnostic accuracy increases. Because 18F-fluorodeoxyglucose (FDG) accumulates at both sites of inflammation and infection, FDG positron emission tomography (PET/CT) shows low specificity. Conclusions A common decision-making process in the diagnosis of periprosthetic joint infection is not yet validated and multidisciplinary integration is mandatory. In this context, nuclear medicine can contribute decisively.
Purpose: To assess agreement between 123I-metaiodobenzylguanidine (MIBG) and Whole Body Magnetic Resonance Imaging with diffusion-weighted whole-body imaging with background body signal suppression (WB MRI-DWIBS) in High and Low, Intermediate risk neuroblastoma, a retrospective review was performed on MIBG and DWIBS paired scans acquired at diagnosis, response-to-therapy steps, after-surgery, off therapy.Methods: 80 paired MIBG and DWIBS scans were acquired for 31 patients between June 2009 and June 2019 within 30 days, without intercurrent therapy. SIOPEN Semi-quantitative scoring systems for NB with 12 body sections was applied at whole body MIBG and WB MRI-DWIBS acquired to evaluate the disease extent. We evaluated specificity, sensitivity, overall accuracy, positive predictive value (PPV) and negative predictive value (NPV) of WB MRI-DWIBS respect MIBG scintigraphy considered as gold standard, and vice versa.Results: DWIBS and MIBG images were concordant in 890 out of the 960 analyzed segments, with high agreement between the two techniques (kendal =0.85 P<0.0001 and Chi 536.5975 p<0.0001). Considering MIBG as gold standard, WB MRI-DWIBS overall accuracy was 93%, sensitivity 78%, specificity 95%, PPV 77% and NPV 96%. Otherwise, MIBG overall accuracy was 93%; sensitivity 77%; specificity 97%; VPP 78%; VPN 95%, considering DWIBS as gold standard. MIBG and WB MRI-DWIBS SIOPEN scoring resulted superimposable (Rho Spearman = 0,88, p < 0,0001).Conclusions: DWIBS and MIBG images showed very high concordance. WB MRI may represent an alternative in weak-avid MIBG tumors and for follow up assessment. An integrated imaging model is proposed for HR, Low and Intermediate Risk protocols.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.