The influence of surface roughness and the presence of adhesion molecules in the culture medium were studied regarding cell adhesion, shape, and proliferation of osteoblast-like cells grown on two types of titanium disk. Type I disks were acid etched and type II disks were sandblasted and acid etched. Surface roughness was determined by contact profilometry and scanning electron microscopy. Chemical composition and oxide thickness of the superficial titanium layer were established with energy dispersive X-ray spectrometry, electron spectroscopy for chemical analysis and auger electron spectroscopy. Titanium release in the culture medium was assessed by inductively coupled plasma-optical emission spectrometry. Osteoblast-like cells (Saos-2) were cultured on both types of titanium disks (1) in standard conditions (DMEM culture medium supplemented with fetal calf serum), (FCS), (2) with the culture medium alone (DMEM alone), (3) in the presence of fibronectin or vitronectin (DMEM supplemented with fibronectin or vitronectin). Cultures were also performed in the presence of monoclonal anti-integrin (beta1, alphav) to test the cell adhesion molecules involved in the cell binding to the titanium surface. We found that sandblasting does not modify the chemical surface composition and that titanium represents only 5-6% (in the atom percentage) of surface elements. Release of titanium in the culture medium was found to increase from 24 to 72 hours. In the absence of FCS, fibronectin, or vitronectin, cells appeared scanty and packed in clusters. On the contrary, cells cultured in the presence of FCS, fibronectin, or vitronectin were flattened with large and thin cytoplasmic expansions. The addition of anti beta1 or alphav integrin subunit monoclonal antibody in the culture medium decreased adhesion and spreading of cells, particularly in the presence of fibronectin. Cell proliferation was significantly higher on culture plastic than on both types of disks, but was increased on rough but not on smooth surfaces. These results indicate that a high surface roughness and presence of fibronectin or vitronectin are critical elements for adhesion, spreading, and proliferation of cells on titanium surfaces.
Some studies have indicated that the risk of fragility fractures in men increases as bone mineral levels decrease, but there is an overlap in the bone mineral density (BMD) measurements between patients with or without fractures. Furthermore, it has been suggested that the biomechanical competence of trabecular bone is dependent not only on the absolute amount of bone present but also on the trabecular microarchitecture. In the present study, 108 men (mean age 52.1 years) with lumbar osteopenia (T score F؊2.
Morphometric analysis of 70 bone biopsies was done in parallel by µCT and histomorphometry. µCT provided higher results for trabecular thickness and separation because of the 3D shape of these anatomical objects.Introduction: Bone histomorphometry is used to explore the various metabolic bone diseases. The technique is done on microscopic 2D sections, and several methods have been proposed to extrapolate 2D measurements to the 3D dimension. X-ray CT is a recently developed imaging tool to appreciate 3D architecture. Recently the use of 2D histomorphometric measurements have been shown to provide discordant results compared with 3D values obtained directly. Material and Methods: Seventy human bone biopsies were removed from patients presenting with metabolic bone diseases. Complete bone biopsies were examined by CT. Bone volume (BV/TV), Tb.Th, and Tb.Sp were measured on the 3D models. Tb.Th and Tb.Sp were measured by a method based on the sphere algorithm. In addition, six images were resliced and transferred to an image analyzer: bone volume and trabecular characteristics were measured after thresholding of the images. Bone cores were embedded undecalcified; histological sections were prepared and measured by routine histomorphometric methods providing another set of values for bone volume and trabecular characteristics. Comparison between the different methods was done by using regression analysis, Bland-Altman, Passing-Bablock, and Mountain plots. Results: Correlations between all parameters were highly significant, but CT overestimated bone volume. The osteoid volume had no influence in this series. Overestimation may have been caused by a double threshold used in CT, giving trabecular boundaries less well defined than on histological sections. Correlations between Tb.Th and Tb.Sp values obtained by 3D or 2D measurements were lower, and 3D analysis always overestimated thickness by ∼50%. These increases could be attributed to the 3D shape of the object because the number of nodes and the size of the marrow cavities were correlated with 3D values. Conclusion:In clinical practice, CT seems to be an interesting method providing reliable morphometric results in less time than conventional histomorphometry. The correlation coefficient is not sufficient to study the agreement between techniques in histomorphometry. The architectural descriptors are influenced by the algorithms used in 3D.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.