Recombinant human acid sphingomyelinase (rhASM) is being developed as an enzyme replacement therapy for patients with acid sphingomyelinase deficiency (Niemann-Pick disease types A and B), which causes sphingomyelin to accumulate in lysosomes. In the acid sphingomyelinase knock-out (ASMKO) mouse, intravenously administered rhASM reduced tissue sphingomyelin levels in a dose-dependent manner. When rhASM was administered to normal rats, mice, and dogs, no toxicity was observed up to a dose of 30mg/kg. However, high doses of rhASM≥10mg/kg administered to ASMKO mice resulted in unexpected toxicity characterized by cardiovascular shock, hepatic inflammation, adrenal hemorrhage, elevations in ceramide and cytokines (especially IL-6, G-CSF, and keratinocyte chemoattractant [KC]), and death. The toxicity could be completely prevented by the administration of several low doses (3mg/kg) of rhASM prior to single or repeated high doses (≥20mg/kg). These results suggest that the observed toxicity involves the rapid breakdown of large amounts of sphingomyelin into ceramide and/or other toxic downstream metabolites, which are known signaling molecules with cardiovascular and pro-inflammatory effects. Our results suggest that the nonclinical safety assessment of novel therapeutics should include the use of specific animal models of disease whenever feasible.
Reconstituted extracellular matrix (ECM) -derived scaffolds are commonly utilized in preclinical tissue engineering studies as delivery vehicles for cells and growth factors. Translation into clinical use requires identifying a sterilization method that effectively removes bacteria but doesn’t harm scaffold function.
To determine effectiveness of sterilization and impact on ECM scaffold integrity and function low temperature ethylene oxide and 15kGy electron beam irradiation techniques were evaluated. Scaffold sterility was assessed in accordance to United States Pharmacopeia Chapter 71. Scaffold matrix degradation was determined in vitro using enzymatic resistance tests and gel electrophoresis. Scaffold mechanics including elastic modulus, yield stress and collapse modulus were tested. Lastly, 14 Yorkshire pigs underwent ACL transection and bio-enhanced ACL repair using sterilized scaffolds. Histologic response of ligament, synovium and lymph nodes was compared at 4, 6, and 8 weeks.
Ethylene oxide as well as electron beam irradiation yielded sterile scaffolds. Scaffold resistance to enzymatic digestion and protein integrity slightly decreased after electron beam irradiation while ethylene oxide altered scaffold matrix. Scaffold elastic modulus and yield stress were increased after electron beam treatment, while collapse modulus was increased after ethylene oxide treatment. No significant changes in ACL dimensions, in vivo scaffold resorption rate, or histologic response of synovium, ligament and lymph nodes with either terminal sterilization technique were detectable.
In conclusion, this study identifies two methods to terminally sterilize an ECM scaffold. In vitro scaffold properties were slightly changed without significantly influencing the biologic responses of the surrounding tissues in vivo. This is a critical step toward translating new tissue engineering strategies to clinical trials.
Incisional hernias commonly occur following abdominal wall surgery. Human acellular dermal matrices (HADM) are widely used in abdominal wall defect repair. Xenograft acellular dermal matrices, particularly those made from porcine tissues (PADM), have recently experienced increased usage. The purpose of this study was to compare the effectiveness of HADM and PADM in the repair of incisional abdominal wall hernias in a rabbit model. A review from earlier work of differences between human allograft acellular dermal matrices (HADM) and porcine xenograft acellular dermal matrices (PADM) demonstrated significant differences (P < 0.05) in mechanical properties: Tensile strength 15.7 MPa vs. 7.7 MPa for HADM and PADM, respectively. Cellular (fibroblast) infiltration was significantly greater for HADM vs. PADM (Armour). The HADM exhibited a more natural, less degraded collagen by electrophoresis as compared to PADM. The rabbit model surgically established an incisional hernia, which was repaired with one of the two acellular dermal matrices 3 weeks after the creation of the abdominal hernia. The animals were euthanized at 4 and 20 weeks and the wounds evaluated. Tissue ingrowth into the implant was significantly faster for the HADM as compared to PADM, 54 vs. 16% at 4 weeks, and 58 vs. 20% for HADM and PADM, respectively at 20 weeks. The original, induced hernia defect (6 cm2) was healed to a greater extent for HADM vs. PADM: 2.7 cm2 unremodeled area for PADM vs. 1.0 cm² for HADM at 20 weeks. The inherent uniformity of tissue ingrowth and remodeling over time was very different for the HADM relative to the PADM. No differences were observed at the 4-week end point. However, the 20-week data exhibited a statistically different level of variability in the remodeling rate with the mean standard deviation of 0.96 for HADM as contrasted to a mean standard deviation of 2.69 for PADM. This was significant with P < 0.05 using a one tail F test for the inherent variability of the standard deviation. No significant differences between the PADM and HADM for adhesion, inflammation, fibrous tissue or neovascularization were noted.
Background: The purpose of this study was to evaluate the biomechanical and histologic properties of rotator cuff repairs using a vented anchor attached to a bioresorbable interpositional scaffold composed of aligned PLGA (poly(L-lactide-co-glycoside)) microfibers in an animal model compared to standard anchors in an ovine model. Methods: Fifty-six (n ¼ 56) skeletally mature sheep were randomly assigned to a repair of an acute infraspinatus tendon detachment using a innovative anchor-PLGA scaffold device (Treatment) or a similar anchor without the scaffold (Control). Animals were humanely euthanized at 7 and 12 weeks post repair. Histologic and biomechanical properties of the repairs were evaluated and compared. Results: The Treatment group had a significantly higher fibroblast count at 7 weeks compared to the Control group. The tendon bone repair distance, percentage perpendicular fibers, new bone formation at the tendon-bone interface, and collagen type III deposition was significantly greater for the Treatment
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.