Background
—Myocardial perfusion reserve can be noninvasively assessed with cardiovascular MR. In this study, the diagnostic accuracy of this technique for the detection of significant coronary artery stenosis was evaluated.
Methods and Results
—In 15 patients with single-vessel coronary artery disease and 5 patients without significant coronary artery disease, the signal intensity–time curves of the first pass of a gadolinium-DTPA bolus injected through a central vein catheter were evaluated before and after dipyridamole infusion to validate the technique. A linear fit was used to determine the upslope, and a cutoff value for the differentiation between the myocardium supplied by stenotic and nonstenotic coronary arteries was defined. The diagnostic accuracy was then examined prospectively in 34 patients with coronary artery disease and was compared with coronary angiography. A significant difference in myocardial perfusion reserve between ischemic and normal myocardial segments (1.08±0.23 and 2.33±0.41;
P
<0.001) was found that resulted in a cutoff value of 1.5 (mean minus 2 SD of normal segments). In the prospective analysis, sensitivity, specificity, and diagnostic accuracy for the detection of coronary artery stenosis (≥75%) were 90%, 83%, and 87%, respectively. Interobserver and intraobserver variabilities for the linear fit were low (
r
=0.96 and 0.99).
Conclusions
—MR first-pass perfusion measurements yielded a high diagnostic accuracy for the detection of coronary artery disease. Myocardial perfusion reserve can be easily and reproducibly determined by a linear fit of the upslope of the signal intensity–time curves.
Background-We studied whether lipid-lowering therapy with atorvastatin (target LDL cholesterol [LDL-C] Ͻ100mg/dL) compared with a moderate treatment regimen that used other lipid-lowering drugs led to a lesser progression of atherosclerosis and to different changes in plaque echogenicity in patients with coronary artery disease. Methods and Results-This study was a 12-month, open-label, randomized, multicenter trial, which used serial 3D intracoronary ultrasound to calculate plaque volume and plaque echogenicity. After transcatheter therapy, 131 patients were randomized (atorvastatin nϭ65, usual care nϭ66). The target plaque had to be a minor lesion (ie, a diameter stenosis of Ͻ50% on angiography). After 12 months, mean LDL-C was reduced from 155 to 86 mg/dL in the atorvastatin group and from 166 to 140 mg/dL in the usual care group. Mean absolute plaque volume showed a larger increase in the usual care group compared with the atorvastatin group (usual care 9.6Ϯ28.1 mm 3 , atorvastatin 1.2Ϯ30.4 mm 3 ; Pϭ0.191). The hyperechogenicity index of the plaque increased to a larger extent for the atorvastatin group than for the usual care group, with a significant treatment effect for the percent change (atorvastatin 42.2%, usual care 10.1%; Pϭ0.021). Conclusions-One year of lipid-lowering therapy to Ͻ100 mg/dL LDL-C most likely led to a slowdown of plaque growth of minor lesions. The significantly larger increase in plaque hyperechogenicity is most likely due to a change in plaque composition. (Circulation. 2001;104:387-392.)
Background-Delayed enhancement (DE) cardiovascular magnetic resonance (CMR) detects acute and chronic myocardial infarction (MI) by visualizing contrast media accumulation in infarcted segments. T2-weighted CMR depicts infarct-related myocardial edema as a marker of acute but not chronic myocardial injury. We investigated the clinical utility of an approach combining both techniques to differentiate acute from chronic MI. Methods and Results-Seventy-three MI patients were studied in 2 groups. Group A consisted of 15 acute MI patients who were studied twice, on day 1 and 3 months after MI. In group B, 58 patients with acute or chronic MI underwent 1 CMR scan. T2-weighted and DE images of matched slices were acquired on a 1.5-T system. In group A, quantitative segmental and region of interest-based analyses were performed to observe signal changes between the acute and chronic phases. In group B, T2-weighted and DE images were examined visually by 2 blinded observers for the presence or absence of hyperintense areas in corresponding segments. For infarct localization, coronary angiography and/or ECG changes served as the reference standard. In group A, the contrast-to-noise ratio on T2-weighted images dropped in the infarcted segments from 2.7Ϯ1.1 on day 1 to 0.1Ϯ1.2 after 3 months (PϽ0.0001). There was no significant change in contrast-to-noise ratio in DE images (1.9Ϯ1.5 versus 1.3Ϯ1.0; PϭNS). The qualitative assessment of T2-weighted and DE images in group B yielded a specificity of 96% to differentiate acute from chronic lesions.
Conclusions-An
Summary
Background
Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes.
Methods
For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813.
Findings
Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0.83, 95% CI 0.63–1.09; p=0.18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1.91, 1.06–3.44; p=0.0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0.82; appendix); these events included pulmonary embolism (two patients [<1%] vs four [1%] patients; p=0.41) and sepsis (seven [1%] vs six [1%]; p=0.79).
Interpretation
In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws.
Funding
National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians’ Services Incorporated.
The two methods provided complementary information: a rough surface of porous microstructure may enhance the rate of cell spreading. Differentiation and calcification occurred on surfaces of both rough and smooth microstructure.
Retrograde ureteral stenting is a good solution for most acutely obstructed ureters. In patients with extrinsic ureteral obstruction a more distal level of obstruction and higher degree of hydronephrosis are associated with a greater likelihood of stent failure. These patients may be better served by percutaneous drainage.
This study demonstrated the superiority of the hydrodynamic approach of cellular reseeding to replace decellularized porcine heart valves with ovine cells with almost complete preservation of extracellular matrix integrity.
Magnetic resonance perfusion measurements allow a reliable assessment of MPR index. An improvement of MPR index can be observed after coronary intervention, which is more pronounced after stenting. Magnetic resonance perfusion measurements allow the assessment and may be useful for the follow-up of patients with coronary artery disease after coronary intervention.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.