Practical ImplicationsThe paper summarizes and explores the peer-reviewed literature on Indoor Air Quality (IAQ) in schools, a field that is of increasing interest to the research community, educators and school facilities managers, and the public at large. These experts generally agree that healthy indoor school environments are a necessity if a high standard of education is to be expected. Although peer-reviewed literature on this subject is sparse, there is a clear indication that classroom ventilation is typically inadequate. Researchers observed specific allergens in classrooms at levels sufficient to affect sensitive occupants. Studies of health symptom associations with IAQ conditions in the classroom are very rare, but taken with more general knowledge of IAQ, suggest that improved ventilation and targeted indoor pollutant source reductions could reduce certain occupant symptoms and improve the standard of health of the occupants.
Student attendance in American public schools is a critical factor in securing limited operational funding. Student and teacher attendance influence academic performance. Limited data exist on indoor air and environmental quality (IEQ) in schools, and how IEQ affects attendance, health, or performance. This study explored the association of student absence with measures of indoor minus outdoor carbon dioxide concentration (dCO 2 ). Absence and dCO 2 data were collected from 409 traditional and 25 portable classrooms from 14 schools located in six school districts in the states of Washington and Idaho. Study classrooms had individual heating, ventilation, and air conditioning (HVAC) systems, except two classrooms without mechanical ventilation.Classroom attributes, student attendance and school-level ethnicity, gender, and socioeconomic status (SES) were included in multivariate modeling. Forty-five percent of classrooms studied had short-term indoor CO 2 concentrations above 1000 parts-permillion (ppm). A 1000 ppm increase in dCO 2 was associated (p < 0.05) with a 0.5% to 0.9% decrease in annual average daily attendance (ADA), corresponding to a relative 10% to 20% increase in student absence. Outside air (ventilation) rates estimated from dCO 2 and other collected data were not associated with absence. Annual ADA was 2% higher (p < 0.0001) in traditional than in portable classrooms. PRACTICAL IMPLICATIONSThis study provides motivation for larger school studies to investigate associations of student attendance, and occupant health and student performance, with longer term indoor minus outdoor carbon dioxide concentrations and more accurately measured ventilation rates. If our findings are confirmed, improving classroom ventilation should be considered a practical means of reducing student absence.Adequate or enhanced ventilation may be achieved, for example, with educational training programs for teachers and facilities staff on ventilation system operation and maintenance. Also, technological interventions such as improved automated control systems could provide continuous ventilation during occupied times, regardless of occupant thermal comfort demands.
Higher indoor concentrations of air pollutants due, in part, to lower ventilation rates are a potential cause of sick building syndrome (SBS) symptoms in office workers. The indoor carbon dioxide (CO2) concentration is an approximate surrogate for indoor concentrations of other occupant-generated pollutants and for ventilation rate per occupant. Using multivariate logistic regression (MLR) analyses, we evaluated the relationship between indoor CO2 concentrations and SBS symptoms in occupants from a probability sample of 41 U.S. office buildings. Two CO2 metrics were constructed: average workday indoor minus average outdoor CO2 (dCO2, range 6-418 ppm), and maximum indoor 1-h moving average CO2 minus outdoor CO2 concentrations (dCO2MAX). MLR analyses quantified dCO2/SBS symptom associations, adjusting for personal and environmental factors. A dose-response relationship (p < 0.05) with odds ratios per 100 ppm dCO2 ranging from 1.2 to 1.5 for sore throat, nose/sinus, tight chest, and wheezing was observed. The dCO2MAX/SBS regression results were similar.
Limited evidence associates inadequate classroom ventilation rates (VRs) with increased illness absence (IA). We investigated relationships between VRs and IA in California elementary schools over two school years in 162 3rd-5th-grade classrooms in 28 schools in three school districts: South Coast (SC), Bay Area (BA), and Central Valley (CV). We estimated relationships between daily IA and VR (estimated from two year daily real-time carbon dioxide in each classroom) in zero-inflated negative binomial models. We also compared IA benefits and energy costs of increased VRs. All school districts had median VRs below the 7.1 l/s-person California standard. For each additional 1 l/s-person of VR, IA was reduced significantly (p<0.05) in models for combined districts (À1.6%) and for SC (À1.2%), and nonsignificantly for districts providing less data: BA (À1.5%) and CV (À1.0%). Assuming associations were causal and generalizable, increasing classroom VRs from the California average (4 l/s-person) to the State standard would decrease IA by 3.4%, increase attendance-linked funding to schools by $33 million annually, and increase costs by only $4 million. Further increasing VRs would provide additional benefits. These findings, while requiring confirmation, suggest that increasing classroom VRs above the State standard would substantially decrease illness absence and produce economic benefits. Practical ImplicationsThese findings suggest a potentially large opportunity to improve the attendance and health of elementary school students in California through provision of increased classroom ventilation. The majority of classrooms in this study provided less ventilation than specified in current State guidelines. If the relationships observed here (and in several prior studies) and the costs and benefits estimated here are confirmed, it would be advantageous to students, their families, and school districts, and highly cost-effective, to ensure that ventilation rates in elementary school classrooms not only meet but substantially exceed current ventilation guidelines. Because specific exposures and response mechanisms involved have not been determined, it is possible that more energy-efficient alternatives to increased ventilation, such as filtration and reduced indoor emissions, might provide similar benefits. Nomenclature
The performance metrics of airflow, sound, and combustion product capture efficiency (CE) were measured for a convenience sample of fifteen cooking exhaust devices, as installed in residences. Results were analyzed to quantify the impact of various device-and installationdependent parameters on CE. Measured maximum airflows were 70% or lower than values noted on product literature for 10 of the devices. Above-the-cooktop devices with flat bottom surfaces (no capture hood) -including exhaust fan/microwave combination appliances -were found to have much lower CE at similar flow rates, compared to devices with capture hoods. For almost all exhaust devices and especially for rear-mounted downdraft exhaust and microwaves, CE was substantially higher for back compared with front burner use. Flow rate, and the extent to which the exhaust device extends over the burners that are in use, also had a large effect on CE. A flow rate of 95 liters per second (200 cubic feet per minute) was necessary, but not sufficient, to attain capture efficiency in excess of 75% for the front burners. A-weighted sound levels in kitchens exceeded 56 dB when operating at the highest fan setting for all 14 devices evaluated for sound performance. Key WordsCarbon monoxide; Natural gas burners; Nitrogen dioxide; Range hood; Task ventilation; Unvented combustion. Practical ImplicationsNatural gas cooking burners and many cooking activities emit pollutants that can reach hazardous levels in homes. Venting range hoods and other cooking exhaust fans are thought to provide adequate protection when used. This study demonstrates that airflows of installed devices are often below advertised values and that less than half of the pollutants emitted by gas cooking burners are removed during many operational conditions. For many devices, achieving capture efficiencies that approach or exceed 75% requires operation at settings that produce prohibitive noise levels. While users can improve performance by preferentially using back burners, results suggest the need for improvements in hood designs to achieve high pollutant capture efficiencies at acceptable noise levels. CitationSinger BC, Delp WW, Apte MG, Price PN. (2012) Performance of installed cooking exhaust devices. Indoor Air, Online 02-Nov-2011.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.