We present a single case of fracture of an Exeter femoral prosthesis at the neck, occurring after a fall from standing height, in a lean 70yr lady at 6 years post implantation. The fracture propagated from the insertion dimple on the superior aspect of the prosthesis shoulder. Materials analysis suggested variance in composition of the alloy, particularly with grain size heterogeneity. Whilst Exeter femoral prosthesis fracture is extremely rare, when it does occur the literature suggests it is often in the context of excessive mechanical stresses (obesity, high offset, falls). However, this case may represent a failure of materials rather than mechanical stresses alone.
Background: Graft fixation with interference screws for anterior cruciate ligament (ACL) reconstruction is a highly successful technique. Polyether ether ketone (PEEK) is a novel thermoplastic polymer with high biocompatibility and mechanical properties that mimic native bone, and it can be imaged on computed tomography or magnetic resonance imaging (MRI) without signal flare. Purpose: To compare the clinical performance of ACL reconstruction with PEEK and titanium interference screws at 2 years and to evaluate a novel method of measuring tunnel volume. Study Design: Randomized controlled trial; Level of evidence, 1. Methods: A total of 133 patients underwent arthroscopic ACL reconstruction with 4-strand hamstring autografts and were randomized to have titanium or PEEK interference screws for femoral and tibial tunnel fixation. At 2 years, subjective Lysholm and International Knee Documentation Committee scores were assessed and clinical examination performed. At 12 months, MRI was performed to assess graft incorporation and cyst formation, and a novel technique was employed to measure tunnel volumes. Results: There were no significant differences in graft rerupture rate, contralateral ACL rupture rate, subjective outcomes, or objective outcomes. In the titanium and PEEK groups, MRI demonstrated high overall rates of graft integration (96%-100% and 90%-93%, respectively) and ligamentization (89% and 84%) and low rates of synovitis (22% and 10%) and cyst formation (0%-18% and 13%-15%). There was a higher proportion of patients with incomplete graft integration within the femoral tunnel in the PEEK group as compared with the titanium group (10% vs 0%, P = .03); however, the authors suggest that metal artifact precluded proper assessment of the graft in the titanium group by MRI. Tunnel volumes also appeared to be equivalent in the 2 groups and were measured with a novel technique that was highly reproducible in the PEEK group secondary to the absence of flare. Conclusion: Two-year clinical analysis of PEEK interference screws for femoral and tibial fixation of ACL reconstructions showed equivalent clinical performance to titanium interference screws. Given the excellent mechanical characteristics, biological compatibility, and absence of metal artifact on MRI, PEEK has become our material of choice for interference screw fixation in ACL reconstruction.
A consecutive series of patients with a hydroxyapatite-coated uncemented total knee replacement (TKR) performed by a single surgeon between 1992 and 1995 was analysed. All patients were invited for clinical review and radiological assessment. Revision for aseptic loosening was the primary outcome. Assessment was based on the Knee Society clinical score (KSS) and an independent radiological analysis. Of 471 TKRs performed in 356 patients, 432 TKRs in 325 patients were followed for a mean of 16.4 years (15 to 18). The 39 TKRs in 31 patients lost to follow-up had a mean KSS of 176 (148 to 198) at a mean of ten years. There were revisions in 26 TKRs (5.5%), of which 11 (2.3%) were for aseptic loosening. Other further surgery was carried out on 49 TKRs (10.4%) including patellar resurfacing in 20, arthrolysis in 19, manipulation under anaesthetic in nine and extensor mechanism reconstruction in one. Survivorship at up to 18 years without aseptic loosening was 96% (95% confidence interval 91.9 to 98.1), at which point the mean KSS was 176 (134 to 200). Of 110 knees that underwent radiological evaluation, osteolysis was observed in five (4.5%), one of which was revised. These data indicate that uncemented hydroxyapatite-coated TKR can achieve favourable long-term survivorship, at least as good as that of cemented designs.
We report the clinical and radiological outcomes of a series of contemporary cementless ceramic-on-ceramic total hip replacements (THRs) at ten years in patients aged ≤ 55 years of age. Pre- and post-operative activity levels are described. A total of 120 consecutive ceramic cementless THRs were performed at a single centre in 110 patients from 1997 to 1999. The mean age of the patients at operation was 45 years (20 to 55). At ten years, four patients had died and six were lost to follow-up, comprising ten hips. The mean post-operative Harris hip score was 94.7 (55 to 100). Radiological analysis was undertaken in 90 available THRs of the surviving 106 hips at final review: all had evidence of stable bony ingrowth, with no cases of osteolysis. Wear was undetectable. There were four revisions. The survival for both components with revision for any cause as an endpoint was 96.5% (95% confidence interval 94.5 to 98.7). The mean modified University of California, Los Angeles activity level rose from a mean of 6.4 (4 to 10) pre-operatively to 9.0 (6 to 10) at the ten-year post-operative period. Alumina ceramic-on-ceramic bearings in cementless primary THR in this series have resulted in good clinical and radiological outcomes with undetectable rates of wear and excellent function in the demanding younger patient group at ten years.
In our current series, a small proportion of LAGB patients developed prosthesis-related infection that typically required port or band removal and usually occurred early in the post-operative course. We have modified our prophylactic antibiotic regime and surgical technique as a result of this review. In selected cases of band infection, bands were salvaged with subsequent acceptable weight loss, suggesting that LAGB salvage in the presence of sepsis may be achievable in some patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.