Long-term survival is poor after BAV alone. BAV as a bridge to percutaneous or surgical aortic valve replacement is feasible, safe, and associated with better outcome than BAV alone.
Patients undergoing PCI with a BVS had increased definite/probable ST and MI during follow-up compared with DES. Further studies with long-term follow-up are needed to assess the risk of ST with a BVS.
Background—
Transcatheter aortic valve implantation is currently being evaluated in patients with severe aortic stenosis who are considered high-risk surgical candidates. This study aimed to detect incidences, causes, and correlates of mortality in patients ineligible to participate in transcatheter aortic valve implantation studies.
Methods and Results—
From April 2007 to July 2009, a cohort of 362 patients with severe aortic stenosis were screened and did not meet the inclusion/exclusion criteria necessary to participate in a transcatheter aortic valve implantation trial. These patients were classified into 2 groups: group 1 (medical): 274 (75.7%): 97 (35.4%) treated medically and 177 (64.6%) treated with balloon aortic valvuloplasty; and group 2 (surgical): 88 (24.3%). The medical/balloon aortic valvuloplasty group had significantly higher clinical risk compared with the surgical group, with significantly higher Society of Thoracic Surgeons score (12.8±7.0 versus 8.5±5.1;
P
<0.001) and logistic European System for Cardiac Operative Risk Evaluation (EuroSCORE) (42.4±22.8 versus 24.4±18.1;
P
<0.001). The medical/balloon aortic valvuloplasty group had a higher New York Heart Association functional class, incidence of renal failure, and lower ejection fraction. During median follow-up of 377.5 days, mortality in the medical/balloon aortic valvuloplasty group was 102 (37.2%), and during median follow-up of 386 days, mortality in the surgical group was 19 (21.5%). Multivariable adjustment analysis identified renal failure (hazard ratio [HR]: 5.60), New York Heart Association class IV (HR: 5.88), and aortic systolic pressure (HR: 0.99) as independent correlates for mortality in the medical group, whereas renal failure (HR: 7.45), Society of Thoracic Surgeons score (STS; HR: 1.09) and logistic EuroSCORE (HR: 1.45) were correlates of mortality in the in the surgical group.
Conclusion—
Patients with severe symptomatic aortic stenosis not included in transcatheter aortic valve implantation trials do poorly and have extremely high mortality rates, especially in nonsurgical groups, and loss of quality of life in surgical groups.
Black race is an independent predictor of definite drug-eluting stent ST. Because clopidogrel compliance was higher in black patients and socioeconomic status was not associated with ST, further investigation into the potential mechanisms of this influence of race on ST must be pursued.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.