This study aimed to analyze the effect of two different techniques of cement application: cement on bone surface (CoB) versus cement on bone surface and implant surface (CoBaI) on the short-term effect of radiolucent lines (RLL) in primary fully cemented total knee arthroplasties (TKA) with patella resurfacing.379 fully cemented TKAs (318 patients) were included in this monocentric study. Preoperative and postoperative at week 4 and 12 month after surgery all patients had a clinical and radiological examination and were administered the Oxford Knee Score (OKS). Cement was applied in two different ways among the two study groups: cement on bone surface (CoB group) or cement on bone surface and implant surface (CoBaI group). The evaluation of the presence of RLL or osteolysis was done as previously described using the updated Knee Society Radiographic Evaluation System.The mean OKS and range of motion improved significantly in both groups at the 4-week and 12-month follow-up, with no significant difference between the groups (CoB vs. CoBaI). RLL were present in 4.7% in the whole study population and were significantly higher in the CoBaI group (10.5%) at the 4-week follow-up. At the 12-month follow-up RLL were seen in 29.8% of the TKAs in the CoBaI group, whereas the incidence was lower in the CoB group (24.0% (n.s.)). There were two revisions in each group. None of these due to aseptic loosening.Our study indicated that the application of bone cement on bone surface only might be more beneficial than onto the bone surface and onto the implant surface as well in respect to the short-term presence of RLL in fully cemented primary TKA.The long-term results will be of interest, especially in respect to aseptic loosening and might guide future directions of bone cement applications in TKA.
Background: The aim of this study is to update the 10-year follow-up survivorship and metal ions levels of a cohort of metal-on-metal (MoM) hip resurfacing (HR) and large-diameter-head (LDH) total hip arthroplasty (THA). Methods: The study is a retrospective analysis of prospectively collected data that compared the outcomes of 24 MoM HR (21 patients) and 15 (11 patients) modular LHD MoM THA at >10 years follow-up. Baseline characteristics as well as intraoperative and postoperative information were collected, including complications, revisions, clinical and radiographic outcomes, and serum metal ions level (Cobalt, Chromium). Metal ion levels were compared using a two-tailed unpaired t-test and Wilcoxon signed-rank test (jamovi v2.3.3.0, Sydney, NSW, Australia). Results: No significant differences were detected in gender, BMI, and ASA score between the two groups. Patients in the modular THA group were significantly older (57 years vs. 46 years; p < 0.05). The HR overall survivorship was 91.7% (22 of 24 hips) with survivorship from implant failure and/or aseptic loosening and/or metal debris related 100% of problems. The modular THA overall survivorship was 86.7% (13 of 15 hips) with survivorship from implant aseptic loosening and metal ions complications of 93.4% (14 of 15 hips). No significant difference was noted when comparing clinical outcomes. Metal ions were significantly lower in the HR group (Co 25.8 nmol/L vs. 89 nmol/L; p < 0.001–Cr 33.5 nmol/L vs. 55.2 nmol/L; p = 0.026). Conclusion: Both implants reported excellent and comparable clinical outcomes at >10 years follow-up. The Adept HR reported remarkable survivorship, in line with the registry data, proving once again its reliability in young active males. The modular LDH THA, despite being discontinued, presented higher reliability and a lower failure rate when compared with similar withdrawn MoM implants. Trunnionosis did not appear to be a significant problem in this particular modular design.
Traditionally, sports Injuries have been sub-optimally managed through Emergency Departments (ED) in the public health system due to a lack of adequate referral processes. Fractures are ruled out through plain radiographs followed by a reactive process involving patient initiated further follow up and investigation. Consequently, significant soft tissue and chondral injuries can go undiagnosed during periods in which early intervention can significantly affect natural progression. The purpose of this quality improvement project was to assess the efficacy of an innovative Sports Injury Pathway introduced to detect and treat significant soft tissue injuries.A Sports Injury Pathway was introduced at Fiona Stanley Hospital (WA, Australia) in April 2019 as a collaboration between the ED, Physiotherapy and Orthopaedic Departments. ED practitioners were advised to have a low threshold for referral, especially in the presence of a history of a twisting knee injury, shoulder dislocation or any suggestion of a hip tendon injury. All referrals were triaged by the Perth Sports Surgery Fellow with early follow-up in our Sports Trauma Clinics with additional investigations if required. A detailed database of all referrals was maintained, and relevant data was extracted for analysis over the first 3 years of this pathway.570 patients were included in the final analysis. 54% of injuries occurred while playing sport, with AFL injuries constituting the most common contact-sports injury (13%). Advanced Scope Physiotherapists were the largest source of referrals (60%). A total of 460 MRI scans were eventually ordered comprising 81% of total referrals. Regarding Knee MRIs, 86% identified a significant structural injury with ACL injuries being the most common (33%) followed by isolated meniscal tears (16%) and multi-ligament knee injuries (11%). 95% of Shoulder MRI scans showed significant pathology. 39% of patients required surgical management, and of these 50% were performed within 3 months from injury.The Fiona Stanley Hospital Sports Injury Pathway has demonstrated its clear value in successfully diagnosing and treating an important cohort of patients who present to our Emergency Department. This low threshold/streamlined referral pathway has found that the vast majority of these patients suffer significant structural injuries that may have been otherwise missed, while providing referring practitioners and patients access to prompt imaging and high-quality Orthopaedic sports trauma services. We recommend the implementation of a similar Sports Injury Pathway at all secondary and tertiary Orthopaedic Centres.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.