The authors tested 4 young healthy subjects walking with a powered knee exoskeleton to determine if it could reduce the metabolic cost of locomotion. Subjects walked with a backpack loaded and unloaded, on a treadmill with inclinations of 0° and 15°, and outdoors with varied natural terrain. Participants walked at a self-selected speed (average 1.0 m/s) for all conditions, except incline treadmill walking (average 0.5 m/s). The authors hypothesized that the knee exoskeleton would reduce the metabolic cost of walking uphill and with a load compared with walking without the exoskeleton. The knee exoskeleton reduced metabolic cost by 4.2% in the 15° incline with the backpack load. All other conditions had an increase in metabolic cost when using the knee exoskeleton compared with not using the exoskeleton. There was more variation in metabolic cost over the outdoor walking course with the knee exoskeleton than without it. Our findings indicate that powered assistance at the knee is more likely to decrease the metabolic cost of walking in uphill conditions and during loaded walking rather than in level conditions without a backpack load. Differences in positive mechanical work demand at the knee for varying conditions may explain the differences in metabolic benefit from the exoskeleton.
Quasi-stiffness characterizes the dynamics of a joint in specific sections of stance-phase and is used in the design of wearable devices to assist walking. We sought to investigate the effect of simulated reduced gravity and walking speed on quasi-stiffness of the hip, knee, and ankle in overground walking. 12 participants walked at 0.4, 0.8, 1.2, and 1.6 m/s in 1, 0.76, 0.54, and 0.31 gravity. We defined 11 delimiting points in stance phase (4 each for the ankle and hip, 3 for the knee) and calculated the quasi-stiffness for 4 phases for both the hip and ankle, and 2 phases for the knee. The R2 value quantified the suitability of the quasi-stiffness models. We found gravity level had a significant effect on 6 phases of quasi-stiffness, while speed significantly affected the quasi-stiffness in 5 phases. We concluded that the intrinsic muscle-tendon unit stiffness was the biggest determinant of quasi-stiffness. Speed had a significant effect on the R2 of all phases of quasi-stiffness. Slow walking (0.4 m/s) was the least accurately modelled walking speed. Our findings showed adaptions in gait strategy when relative power and strength of the joints were increased in low gravity, which has implications for prosthesis and exoskeleton design.
Reducing the mechanical load on the human body through simulated reduced gravity can reveal important insight into locomotion biomechanics. The purpose of this study was to quantify the effects of simulated reduced gravity on muscle activation levels and lower limb biomechanics across a range of overground walking speeds. Our overall hypothesis was that muscle activation amplitudes would not decrease proportionally to gravity level. We recruited 12 participants (6 female, 6 male) to walk overground at 1.0, 0.76, 0.55, and 0.31 G for four speeds: 0.4, 0.8, 1.2, and 1.6 ms-1. We found that peak ground reaction forces, peak knee extension moment in early stance, peak hip flexion moment, and peak ankle extension moment all decreased substantially with reduced gravity. The peak knee extension moment at late stance/early swing did not change with gravity. The effect of gravity on muscle activity amplitude varied considerably with muscle and speed, often varying nonlinearly with gravity level. Quadriceps (rectus femoris, vastus lateralis, & vastus medialis) and medial gastrocnemius activity decreased in stance phase with reduced gravity. Soleus and lateral gastrocnemius activity had no statistical differences with gravity level. Tibialis anterior and biceps femoris increased with simulated reduced gravity in swing and stance phase, respectively. The uncoupled relationship between simulated gravity level and muscle activity have important implications for understanding biomechanical muscle functions during human walking and for the use of bodyweight support for gait rehabilitation after injury.
Walking with bodyweight support is a vital tool for both gait rehabilitation and biomechanics research. There are few commercially available bodyweight support systems for overground walking that are able to provide a near constant lifting force of more than 50% bodyweight. The devices that do exist are expensive and are not often used outside of rehabilitation clinics. Our aim was to design, build, and validate a bodyweight support device for overground walking that: 1) cost less than $5,000, 2) could support up to 75% of the users' bodyweight (BW), and 3) had small (±5 % BW) fluctuations in force. We used pairs of constant force springs to provide the constant lifting force. To validate the force fluctuation, we recruited 8 participants to walk at 0.4, 0.8, 1.2 and 1.6 m/s with 0, 22, 46 and 69% of their bodyweight supported. We used a load cell to measure force through the system and motion capture data to create a vector of the supplied lifting force. The final prototype cost less than $4,000 and was able to support 80% of the users' bodyweight. Fluctuations in vertical force increased with speed and bodyweight support, reaching a maximum of 10% at 1.6 m/s and 69% BW support.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.