This paper is focusing on the measurement methods of the femoral head at the hip hemiarthroplasty surgery. The measurement result of 10 femoral head specimens using four different methods of Vernier calliper, ring gauge, CT scan and X-ray were compared. It is generally believed that under sizing of the implant may cover the errors of the measurement methods, but the result of this study shows that the callipers and ring gauge measurements are more reliable than the CT and X-ray methods. Conclusively, the full-circle ring gauge or femoral head template is the recommendation for measurement of the femoral head diameter in the hip hemiarthroplasty surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.