In various industrial processes such as petroleum refineries, crude oil must be heated to the required temperature. Here a study of a heat exchanger problem of a catalytic naphtha reforming unit of an SKIKDA refinery (RA1K) is carried out. In this unit the feed (naphtha and recycle gas) is required to enter the first reactor of the reaction section at 471℃, while the feed inlet temperature at the reactor is only 450℃. This problem appeared after starting the unit with a mass flow of 60% of the naphtha. The essential device for heating the charge before entering the reactor is shell-and-tube heat exchanger. In the present study, the Kern method is used to check the heat exchanger in the design and experimental cases. The Aspen HYSYS software has been used to study the influence of various naphtha mass flow rates on the thermal performance of a heat exchanger. The outlet feed temperature was examined for each mass flow rate of naphtha (i.e., 60, 70, 80, 90 and 100%). The simulation results show the important role of the studied parameters in the thermal performance enhancement of heat exchanger, where the case of a mass flow of 60% of the naphtha, the temperature 471℃, provided for by the design, is obtained with an H2/HC ratio of 4.68.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.