OBJECTIVE To investigate glycemic and psychosocial outcomes with hybrid closed-loop (HCL) versus user-determined insulin dosing with multiple daily injections (MDI) or insulin pump (i.e., standard therapy for most adults with type 1 diabetes). RESEARCH DESIGN AND METHODS Adults with type 1 diabetes using MDI or insulin pump without continuous glucose monitoring (CGM) were randomized to 26 weeks of HCL (Medtronic 670G) or continuation of current therapy. The primary outcome was masked CGM time in range (TIR; 70–180 mg/dL) during the final 3 weeks. RESULTS Participants were randomized to HCL (n = 61) or control (n = 59). Baseline mean (SD) age was 44.2 (11.7) years, HbA1c was 7.4% (0.9%) (57 [10] mmol/mol), 53% were women, and 51% used MDI. HCL TIR increased from (baseline) 55% (13%) to (26 weeks) 70% (10%) with the control group unchanged: (baseline) 55% (12%) and (26 weeks) 55% (13%) (difference 15% [95% CI 11, 19]; P < 0.0001). For HCL, HbA1c was lower (median [95% CI] difference −0.4% [−0.6, −0.2]; −4 mmol/mol [−7, −2]; P < 0.0001) and diabetes-specific positive well-being was higher (difference 1.2 [95% CI 0.4, 1.9]; P < 0.0048) without a deterioration in diabetes distress, perceived sleep quality, or cognition. Seventeen (9 device-related) versus 13 serious adverse events occurred in the HCL and control groups, respectively. CONCLUSIONS In adults with type 1 diabetes, 26 weeks of HCL improved TIR, HbA1c, and their sense of satisfaction from managing their diabetes compared with those continuing with user-determined insulin dosing and self-monitoring of blood glucose. For most people living with type 1 diabetes globally, this trial demonstrates that HCL is feasible, acceptable, and advantageous.
Lower admission pH levels and higher admission serum potassium levels are independent predictors of slower time to resolution of DKA. This may assist to stratify patients with DKA using markers of severity to determine who may benefit from closer monitoring and to predict LOS.
OBJECTIVE To assess the efficacy and safety of closed-loop insulin delivery compared with sensor-augmented pump therapy among older adults with type 1 diabetes. RESEARCH DESIGN AND METHODS This open-label, randomized (1:1), crossover trial compared 4 months of closed-loop versus sensor-augmented pump therapy. Eligible adults were aged ≥60 years, with type 1 diabetes (duration ≥10 years), using an insulin pump. The primary outcome was continuous glucose monitoring (CGM) time in range (TIR; 3.9–10.0 mmol/L). RESULTS There were 30 participants (mean age 67 [SD 5] years), with median type 1 diabetes duration of 38 years (interquartile range [IQR] 20–47), randomized (n = 15 to each sequence); all completed the trial. The mean TIR was 75.2% (SD 6.3) during the closed-loop stage and 69.0% (9.1) during the sensor-augmented pump stage (difference of 6.2 percentage points [95% CI 4.4 to 8.0]; P < 0.0001). All prespecified CGM metrics favored closed loop over the sensor-augmented pump; benefits were greatest overnight. Closed loop reduced CGM time <3.9 mmol/L during 24 h/day by 0.5 percentage points (95% CI 0.3 to 1.1; P = 0.0005) and overnight by 0.8 percentage points (0.4 to 1.1; P < 0.0001) compared with sensor-augmented pump. There was no significant difference in HbA1c between closed-loop versus sensor-augmented pump stages (7.3% [IQR, 7.1–7.5] (56 mmol/mol [54–59]) vs. 7.5% [7.1–7.9] (59 mmol/mol [54–62]), respectively; P = 0.13). Three severe hypoglycemia events occurred during the closed-loop stage and two occurred during the sensor-augmented pump stage; no hypoglycemic events required hospitalization. One episode of diabetic ketoacidosis occurred during the sensor-augmented pump stage; no serious adverse events occurred during the closed-loop stage. CONCLUSION Closed-loop therapy is an effective treatment option for older adults with long-duration type 1 diabetes, and no safety issues were identified. These older adults had higher TIR accompanied by less time below range during closed loop than during sensor-augmented pump therapy. Of particular clinical importance, closed loop reduced the time spent in hypoglycemic range overnight.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.