Antineutrophil cytoplasmic antibody (ANCA)-associated vasculitis (AAV) are systemic autoimmune diseases that may lead to renal failure due to the infiltration of mononuclear cells and the destruction of small- and medium-sized blood vessels. It has been shown that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may trigger the presentation or exacerbation of autoimmune diseases. Crescentic glomerulonephritis (GN) has rarely been reported in patients with Coronavirus disease-2019 (COVID-19). We present rare two cases with AAV after a recent diagnosis of COVID-19. The first case was 26-year-old male patient, who was presented with acute kidney injury after COVID-19. Serum creatinine increased and active urine sediment was seen. Serological evaluation showed anti-myeloperoxidase antibody was at a level of 80.6 U/mL. Kidney biopsy showed necrotizing GN with cellular crescents. Methylprednisolone, cyclophosphamide and plasma exchange were administered. He was discharged with hemodialysis. Second case was a 36-year-old female who was hospitalized because of fever, cough and dyspnea. After she was diagnosed with COVID-19, she had total hearing loss, with cavitary lesions on bilateral lung parenchyma and an acute kidney injury. Serological evaluation showed an elevated anti-proteinase-3 with a level of 1:32. Kidney biopsy showed necrotizing GN with cellular crescents. Renal function improved after methylprednisolone and cyclophosphamide treatment. With a systematic review of the literature, we found four cases of new-onset AAV due to COVID-19. Herein, we discuss two cases and provide a literature review on cases of new-onset pauci-immune GN after COVID-19 infection.
Our study showed that the frequency of accurate devices was higher among validated sphygmomanometers compared with nonvalidated sphygmomanometers. To our knowledge, our study is the first to demonstrate the relationship between accuracy and validation of home sphygmomanometers. The frequency of device-related errors can be decreased by training patients and supervising the blood pressure device market. Nonprofit organizations can help patients to overcome some of the problems in the blood pressure device market.
Patients with chronic renal failure on regular hemodialysis program show significant alterations at LV longitudinal myocardial function parameters assessed by color TDI.
We aimed to determine whether red cell distribution width (RDW) and mean platelet volume (MPV) values differ between patients with reactive amyloid A (AA) amyloidosis due to chronic inflammatory disease and in healthy participants. In this study, 33 patients with AA amyloidosis and 40 age- and sex-matched healthy controls were enrolled. Erythrocyte sedimentation rate (ESR), RDW, platelet count (PLT), and MPV levels were retrospectively obtained from our computerized patient database. We found RDW, ESR, and PLT levels to be significantly higher in patients with AA amyloidosis compared with the controls (P < .0001). Mean platelet volume was significantly lower in patients with amyloidosis (P < .0001). Inflammatory diseases such as AA amyloidosis may demonstrate low MPV and high RDW levels.
Self-measurement of blood pressure (BP) at home is more common than 10 years ago and encouraged by current guidelines to increase patient adherence to treatment and reach the goal of target BP. The aims of this study are to evaluate the accuracy of home sphygmomanometers and to investigate behavior/knowledge of the sphygmomanometer owners. A campaign was planned to determine the accuracy of home sphygmomanometers in 2006. Seven hundred and twenty-three home sphygmomanometers were brought by individuals to the University Hospital Hypertension Clinic within 1 year and 693 (96%) of the devices were in adequate working condition and suitable for analysis. Four hundred and thirty-nine (63%) of the sphygmomanometers were automatic. Four hundred and eleven (59.3%) of the 693 sphygmomanometer were inaccurate. About 80% (256/320) of the wrist devices were inaccurate. Most studies evaluating the accuracy of sphygmomanometers are conducted in hospital or primary care settings; studies investigating home sphygmomanometers are rare. High frequency of inaccurate home devices is a major public health problem. In conclusion, inaccurate devices have been used in home BP measurements frequently and frequency of device-related errors can be decreased by awareness and training of the patients. Physicians and healthcare providers should advise the patients to check the accuracy of their home sphygmomanometers regularly.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.