Digital image correlation (DIC) is a highly accurate image-based deformation measurement method achieving a repeatability in the range of σ = 10−5 relative to the field-of-view. The method is well accepted in material testing for non-contact strain measurement. However, the correlation makes it computationally slow on conventional, CPU-based computers. Recently, there have been DIC implementations based on graphics processing units (GPU) for strain-field evaluations with numerous templates per image at rather low image rates, but there are no real-time implementations for fast strain measurements with sampling rates above 1 kHz. In this article, a GPU-based 2D-DIC system is described achieving a strain sampling rate of 1.2 kHz with a latency of less than 2 milliseconds. In addition, the system uses the incidental, characteristic microstructure of the specimen surface for marker-free correlation, without need for any surface preparation—even on polished hourglass specimen. The system generates an elongation signal for standard PID-controllers of testing machines so that it directly replaces mechanical extensometers. Strain-controlled LCF measurements of steel, aluminum, and nickel-based superalloys at temperatures of up to 1000 °C are reported and the performance is compared to other path-dependent and path-independent DIC systems. According to our knowledge, this is one of the first GPU-based image processing systems for real-time closed-loop applications.
This article reports a novel GPU-based 2D digital image correlation system (2D-DIC) overcoming two major limitations of this technique: It measures marker-free, i.e. without sample preparation, and the sampling rate meets the recommendations of ASTM E606. The GPU implementation enables zero-normalized cross correlation (ZNCC) calculation rates of up to 25 kHz for 256 x 256 pixel ROIs. This high-speed image processing system is combined with a high-resolution telecentric lens observing a 10 mm field-of-view, coaxial LED illumination, and a camera acquiring 2040 x 256 pixel images with 1.2 kHz. The optics resolve the microstructure of the surface even of polished cylindrical steel specimen. The displacement uncertainty is below 0.5 µm and the reproducibility in zero-strain tests approximately 10(1 ) of the field-of-view. For strain-controlled testing, a minimum of two displacement subsets per image are evaluated for average strain with a sampling rate of 1.2 kHz. Similar to mechanical extensometers, an analogue 0-10V displacement signal serves as a feedback for standard PID controllers. The average latency is below 2 ms allowing for cycle frequencies up to 10 Hz. For strain-field measurement, the number of ROIs limits the frame rate, e.g., the correlation rate of 25 kHz is sufficient to evaluate 10 images per second with 2500 ROIs each. This frame rate is still sufficient to compare the maximum and minimum strain fields within a cycle in real-time, e.g. for crack detection. The result is a marker-free and non-contact DIC sensor suitable for both strain-controlled fatigue testing and real-time full-field strain evaluation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.