Objective To correlate arrhythmic symptoms with the presence of significant arrhythmias through the external event monitoring (web-loop).Methods Between January and December 2011, the web-loop was connected to 112 patients (46% of them were women, mean age 52±21 years old). Specific arrhythmic symptoms were defined as palpitations, pre-syncope and syncope observed during the monitoring. Supraventricular tachycardia, atrial flutter or fibrillation, ventricular tachycardia, pauses greater than 2 seconds or advanced atrioventricular block were classified as significant arrhythmia. The association between symptoms and significant arrhythmias were analyzed.Results The web-loop recorded arrhythmic symptoms in 74 (66%) patients. Of these, in only 14 (19%) patients the association between symptoms and significant cardiac arrhythmia was detected. Moreover, significant arrhythmia was found in 11 (9.8%) asymptomatic patients. There was no association between presence of major symptoms and significant cardiac arrhythmia (OR=0.57, CI95%: 0.21-1.57; p=0.23).Conclusion We found no association between major symptoms and significant cardiac arrhythmia in patients submitted to event recorder monitoring. Event loop recorder was useful to elucidate cases of palpitations and syncope in symptomatic patients.
Objective To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring.Methods Twenty-eight patients with an indication for hemodynamic study were selected for this investigation, and kept in supine position. Before starting the coronary angiography, they were instructed about the use of the left radial bracelet for beat-to-beat blood pressure monitoring.Results There was a significant difference between the time required for the catheterization laboratory team to acquire the first invasive blood pressure reading and the time to obtain the first beat-to-beat reading (11.1±5.1 and 1.5±1.8, respectively; p<0.0001). The intraclass correlation coefficients (95%CI) of systolic and diastolic blood pressures were 0.897 (0.780-0.952) and 0.876 (0.734-0.942), indicating good reproducibility.Conclusion This study showed the process to develop a beat-to-beat blood pressure monitoring device. When compared to invasive blood pressure monitoring, there were no significant differences between the two methods. This technique may play a promising coadjuvant role when combined with invasive monitoring during coronary angiography procedures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.