Multiphoton imaging techniques that convert low-energy excitation to higher energy emission are widely used to improve signal over background, reduce scatter, and limit photodamage. Lanthanide-doped upconverting nanoparticles (UCNPs) are among the most efficient multiphoton probes, but even UCNPs with optimized lanthanide dopant levels require laser intensities that may be problematic. Here, we develop protein-sized, alloyed UCNPs (aUCNPs) that can be imaged individually at laser intensities >300-fold lower than needed for comparably sized doped UCNPs. Using single UCNP characterization and kinetic modeling, we find that addition of inert shells changes optimal lanthanide content from Yb3+, Er3+-doped NaYF4 nanocrystals to fully alloyed compositions. At high levels, emitter Er3+ ions can adopt a second role to enhance aUCNP absorption cross-section by desaturating sensitizer Yb3+ or by absorbing photons directly. Core/shell aUCNPs 12 nm in total diameter can be imaged through deep tissue in live mice using a laser intensity of 0.1 W cm−2.
Background and purposeTreatment of intermediate and high-risk prostate cancer with a high BED has been shown to increase recurrence free survival (RFS). While high dose rate (HDR) brachytherapy, given as a boost is effective in delivering a high BED, many patients are not candidates for the procedure or wish to avoid an invasive procedure. We evaluated the use of stereotactic body radiotherapy (SBRT) as a boost, with dosimetry modeled after HDR-boost.Material and methodsFifty patients were treated with two fractions of SBRT (9.5-10.5 Gy/fraction) after 45 Gy external-beam radiotherapy, with 48 eligible for analysis at a median follow-up of 42.7 months.ResultsThe Kaplan-Meier estimates of biochemical control post-radiation therapy (95 % Confidence Interval) at 3, 4 and 5 years were 95 % (81–99 %), 90 % (72–97 %) and 90 % (72–97 %), respectively (not counting 2 patients with a PSA bounce as failures). RFS (defined as disease recurrence or death) estimates at 3, 4 and 5 years were 92 % (77–97 %), 88 % (69–95 %) and 83 % (62–93 %) if patients with PSA bounces are not counted as failures, and were 90 % (75–96 %), 85 % (67–94 %) and 75 % (53–88 %) if they were. The median time to PSA nadir was 26.2 months (range 5.8–82.9 months), with a median PSA nadir of 0.05 ng/mL (range <0.01–1.99 ng/mL). 2 patients had a “benign PSA bounce”, and 4 patients recurred with radiographic evidence of recurrence beyond the RT fields. Treatment was well tolerated with no acute G3 or higher GI or GU toxicity and only a single G3 late GU toxicity of urinary obstruction.ConclusionsSBRT boost is well-tolerated for intermediate and high-risk prostate cancer patients with good biochemical outcomes and low toxicity.
This work presents a microfluidics-integrated label-free flow cytometry-on-a-CMOS platform for the characterization of the cytoplasm dielectric properties at microwave frequencies. Compared with MHz impedance cytometers, operating at GHz frequencies offers direct intracellular permittivity probing due to electric fields penetrating through the cellular membrane. To overcome the detection challenges at high frequencies, the spectrometer employs on-chip oscillator-based sensors, which embeds simultaneous frequency generation, electrode excitation, and signal detection capabilities. By employing an injection-locking phase-detection technique, the spectrometer offers state-of-the-art sensitivity, achieving a less than 1 aFrms capacitance detection limit (or 5 ppm in frequency-shift) at a 100 kHz noise filtering bandwidth, enabling high throughput (>1k cells per s), with a measured cellular SNR of more than 28 dB. With CMOS/microfluidics co-design, we distribute four sensing channels at 6.5, 11, 17.5, and 30 GHz in an arrayed format whereas the frequencies are selected to center around the water relaxation frequency at 18 GHz. An issue in the integration of CMOS and microfluidics due to size mismatch is also addressed through introducing a cost-efficient epoxy-molding technique. With 3-D hydrodynamic focusing microfluidics, we perform characterization on four different cell lines including two breast cell lines (MCF-10A and MDA-MB-231) and two leukocyte cell lines (K-562 and THP-1). After normalizing the higher frequency signals to the 6.5 GHz ones, the size-independent dielectric opacity shows a differentiable distribution at 17.5 GHz between normal (0.905 ± 0.160, mean ± std.) and highly metastatic (1.033 ± 0.107) breast cells with p ≪ 0.001.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.