Objectives Anterior column fractures can be seen as either isolated or accompanied by many types of complex acetabulum fractures. The aim of this study was to biomechanically compare the stability of a standard pelvic brim plate with a more laterally located suprapectineal plate, which is more commonly used in minimally invasive application, on an intermediate height anterior column fracture model under dynamic and static loading. Materials and methods Right side, adult, foam cortical shell artificial hemipelvis models were used (Sawbones, Pacific Research Laboratories, Vashon, WA, USA). Twenty-four (24) pieces of foam cortical shell artificial hemipelvis models were separated into three groups (M, L, and control). In group “M,” a suprapectineal plate was placed medially just adjacent to the pelvic brim. In group “L,” a laterally located suprapectineal plate was placed 2 cm lateral of the pelvic brim at its most proximal point. Then, dynamic load testing of 1000 cycles between 50 N and 500 N force and a static load test of 1.2 kN at 2 mm/minute were applied. Dynamic and static tests were conducted on an axial compression device. Displacements were measured after dynamic and static loading conditions. Results In the dynamic loading test at the AL point (superior intersection of the fracture line with the acetabular roof), the median displacement was significantly higher in group L than in group M (0.12 (IQR: 0.058-0.8125) mm and 0.04 (IQR: 0.03-0.065) mm (p = 0.02)). There was no other statistically significant difference in the displacement amounts in both dynamic and static loading conditions at other measurement points. The comparison of the stiffness of the M and L groups showed no statistically significant results, while the control group was significantly more rigid than both the M and L groups (p = 0.04 for both). None of the artificial hemipelvis models was found to be fractured at the end of the test. Conclusion Suprapectineal plates, placed on either the medial or lateral aspect of the pelvic brim, may be used for the fixation of anterior column-type fractures to provide rigid fixation and stability. As plate location did not impact stiffness and stability, the results suggest that surgeons have flexibility in determining the fixation based on accessibility, fracture pattern, and surgeon experience.
Background: Tibial slope measurements performed using only the proximal part of tibia ignore the native tibial anatomical axis. Our first aim is to measure the native medial, lateral and total tibial slope angles of gender groups using the whole tibial anatomical axis on computerized tomography-based three-dimensional anatomical models. The second aim is to determine the correlation between proximal and whole tibial anatomical axis for measurement of medial, lateral, and total tibial slope angles. Methods: We randomly selected 100 females and 100 males between 18-60 years of age. Three-dimensional anatomical models of right and left tibia were created. The gender-specific differences of medial, lateral, and total tibial slope angles according to proximal and whole tibial anatomical axis were measured. Correlation coefficients (r) of medial, lateral, and total tibial slope angles measured with proximal and whole tibial anatomical axis were calculated. Results: The mean age was 47.1 years. A statistically significant difference was observed between female (7.1 ± 3) and male (8.2 ± 2.5) groups in terms of mean lateral tibial slope angles according to the whole tibial anatomical axis (p=0.008). A strong correlation between proximal and whole tibial anatomical axis for all tibial slope angle measurements was detected. Conclusion: The method we determined for 3D measurement of medial, lateral and total tibial slope angles using proximal tibial anatomical axis has a strong correlation with slope angles measured in accordance with the whole tibial anatomical axis. Our 3D tibial slope angle measurement method on the proximal tibia has high reliability and could be used in the daily practice.
Background and Objectives: This study aimed to examine the ventricular repolarization (VR) disturbances of patients operated on for acute spontaneous Achilles tendon ruptures (ATRs), by comparing them with a healthy individual control group. Materials and Methods: Between June 2014 and July 2020, a total of 29 patients (28 males, 1 female; mean age: 40 ± 9.78 years; range, 21–66 years) who presented to the emergency department within the first three weeks of injury, and were diagnosed with acute spontaneous ATRs and treated with an open Krackow suture technique, were retrospectively analyzed. Fifty-two healthy individuals (47 males, 5 females; mean age: 39 ± 11.45 years; range, 21–66 years) were recruited as a control group from the cardiology outpatient clinic. Clinical data (demographic features and laboratory parameters (serum glucose, creatinine, hemoglobin, white blood cell count, and lipid profile)) and electrocardiograms (ECGs) were collected from medical records. ECGs were evaluated for heart rate and VR parameters of QRS width, QTc interval, cQTd interval, Tp-e interval, and Tp-e/QT ratio. The clinical data and these ECG parameters were compared between groups. Results: There was no statistically significant difference between groups, regarding clinical data (all p < 0.05). Among ECG parameters, heart rate, QRS width, QTc interval, and cQTd interval were similar between groups (all p < 0.05). There were two important statistically significant findings of this research: The mean Tp-e interval was longer (ATR group: 72.4 ± 24.7, control group: 58.8 ± 14.5, p: 0.01), and the Tp-e/QT ratio was higher (ATR group: 0.2 ± 0.1, control group: 0.16 ± 0.4, p: 0.027) in the ATR group. Conclusions: According to the ventricular repolarization disturbances found in this study, patients with ATR may be at a higher risk of ventricular arrhythmia than healthy people. As a result, ATR patients should be assessed for ventricular arrhythmia risk by an expert cardiologist.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.