Frequent PVC is an uncommon yet significant cause of CRT nonresponse. Radiofrequency ablation of PVC foci improves LV function and New York Heart Association class and promotes reverse remodeling in CRT nonresponders. PVC ablation may be used to enhance CRT efficacy in nonresponders with significant PVC burden.
Background:The clinical significance of mildly elevated troponins in patients presenting to the emergency room (ER) with atrial fibrillation (AF) is not well understood. Hypothesis: We hypothesized that mildly elevated troponin in these patients is associated with adverse cardiovascular outcomes. Methods: In a multi-center, retrospective study, 662 patients with AF were divided into 3 groups based on troponin levels: group 1, mildly elevated; group 2, normal; and group 3, troponin not measured. Primary outcome was the combined endpoint of all-cause mortality and myocardial infarction (MI) at one year. Results: Levels of TnI were measured in 503 (76%) patients. They were elevated in 220 patients (33%, group 1; mean, 0.56 ng/mL), normal in 283 patients (43%, group 2), and not measured in 159 patients (24%, group 3). Significantly more cardiac testing was done at index hospitalization in group 1 (50%) compared with groups 2 and 3 (28% and 29%, P ≤ 0.001) and in the following year (29%, vs 20% and 17%, P = 0.02). Group 1 had more positive tests (62%) compared with groups 2 and 3 (25% and 43%, P ≤ 0.001). Group 1 had a significantly higher occurrence of the primary endpoint (22%, vs 10% and 15%, P = 0.002), driven primarily by a higher incidence of MI in group 1 (7%, vs 1% and 2%, P = 0.001). Conclusions: Troponin levels are routinely checked in a majority of patients presenting to the emergency department with AF. Even mildly elevated TnI is associated with a greater incidence of coronary artery disease on diagnostic testing and a higher 1-year incidence of MI.
Our findings showed that, with RMN, there is an increased success related to the catheter tip utilized. However, in patients with right ventricular outflow origin, the standard 4-mm tip provided adequate lesions for successful ablation in most patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.