The remodeling behavior of bone is influenced by its mechanical environment. By mapping bone's mechanical properties in detail, orthopedic implants with respect to its mechanical properties could stimulate and harness remodeling to improve patient outcomes. In this study, multiaxial apparent modulus and strength of cadaveric proximal tibial bone are mapped and predicted from computed tomography (CT) derived apparent density. Group differences are identified from testing order, subchondral depth, condyle, and sub-meniscal bone with covariates; age and gender. Axial modulus is 50% greater than the transverse modulus. Medial axial modulus is 30% greater than the lateral side. On the lateral side, axial modulus decreases by 50% from proximal to 25 mm distal. On the medial side, axial modulus remains relatively constant. Differences are quantified for density and multiaxial modulus across all subchondral depths, and different power law relationships are provided for each location. Density explains 75% of variation when grouped by subchondral depth and condyle. Yield strength is well-predicted across all test directions, with density predicting 81% of axial strength variation and no differences over subchondral depth. Quantified mapping of bone multiaxial modulus based on condyle and subchondral depth is shown for the first time in a clinically viable protocol using conventional CT.
Aims Unicompartmental and total knee arthroplasty (UKA and TKA) are successful treatments for osteoarthritis, but the solid metal implants disrupt the natural distribution of stress and strain which can lead to bone loss over time. This generates problems if the implant needs to be revised. This study investigates whether titanium lattice UKA and TKA implants can maintain natural load transfer in the proximal tibia. Methods In a cadaveric model, UKA and TKA procedures were performed on eight fresh-frozen knee specimens, using conventional (solid) and titanium lattice tibial implants. Stress at the bone-implant interfaces were measured and compared to the native knee. Results Titanium lattice implants were able to restore the mechanical environment of the native tibia for both UKA and TKA designs. Maximum stress at the bone-implant interface ranged from 1.2 MPa to 3.3 MPa compared with 1.3 MPa to 2.7 MPa for the native tibia. The conventional solid UKA and TKA implants reduced the maximum stress in the bone by a factor of 10 and caused > 70% of bone surface area to be underloaded compared to the native tibia. Conclusion Titanium lattice implants maintained the natural mechanical loading in the proximal tibia after UKA and TKA, but conventional solid implants did not. This is an exciting first step towards implants that maintain bone health, but such implants also have to meet fatigue and micromotion criteria to be clinically viable. Cite this article: Bone Joint Res 2022;11(2):91–101.
The increasing use of surgical robotics has provoked the necessity for new medical imaging methods. Many assistive surgical robotic systems influence the surgeon's movements based on a model of constraints and boundaries driven by anatomy. This study aims to demonstrate that Near-Infrared Fluorescence (NIRF) imaging could be applied in surgical applications to provide subsurface mapping of capillaries beneath soft tissue as a method for imaging active constraints. The manufacture of a system for imaging in the near-infrared wavelength range is presented, followed by a description of computational methods for stereo-post-processing and data acquisition and testing used to demonstrate that the proposed methods are viable. The results demonstrate that it is possible to use NIRF for the imaging of a capillary submersed up to 11 mm below a soft tissue phantom, over a range of angles from 0 • through 45 •. Phantom depth has been measured to an accuracy of ±3 mm and phantom angle to a constant accuracy of ±1.6 •. These findings suggest that NIRF could be used for the next generation of medical imaging in surgical robotics and provide a basis for future research into real-time depth perception in the mapping of active constraints.
The success of cementless orthopaedic implants relies on bony ingrowth and active bone remodelling. Much research effort is invested to develop implants with controllable surface roughness and internal porous architectures that encourage these biological processes. Evaluation of these implants requires long-term and costly animal studies, which do not always yield the desired outcome requiring iteration. The aim of our study is to develop a cost-effective method to prescreen design parameters prior to animal trials to streamline implant development and reduce live animal testing burden.Ex vivo porcine cancellous bone cylinders (n=6, Ø20×12mm) were extracted from porcine knee joints with a computer-numerically-controlled milling machine under sterile conditions within 4 hours of animal sacrifice. The bone discs were implanted with Ø6×12mm additive manufactured porous titanium implants and were then cultured for 21days. Half underwent static culture in medium (DMEM, 10% FBS, 1% antibiotics) at 37°C and 5% CO2. The rest were cultured in novel high-throughput stacked configuration in a bioreactor that simulated physiological conditions after surgery: the fluid flow and cyclic compression force were set at 10ml/min and 10–150 N (1Hz,5000 cycles/day) respectively. Stains were administered at days 7 and 14. Samples were evaluated with widefield microscopy, scanning electron microscopy (SEM) and with histology.More bone remodelling was observed on the samples cultured within the bioreactor: widefield imaging showed more remodelling at the boundaries between the implant-bone interface, while SEM revealed immature bone tissue integration within the pores of the implant. Histological analysis confirmed these results, with many more trabecular struts with new osteoid formation on the samples cultured dynamically compared to static ones.Ex vivo bone can be used to analyse new implant technologies with lower cost and ethical impact than animal trial. Physiological conditions (load and fluid flow) promoted bone ingrowth and remodelling.
Bone remodeling is mediated by several factors including strain. An increase in strain between 1% and 10% compared to homeostasis can trigger bone formation. We aim to create an orthopedic implant using clinically established imaging and manufacturing methods that induces this strain control in human bone. Titanium scaffolds were manufactured with multiaxial apparent modulus tailored to the mechanical properties of bone defined from computed tomography scans of cadaver human tibiae. Five bone cubes were tested with corresponding titanium scaffolds by loading under compression, which is similar to the implanted tibia loading condition. Bone strain was precisely controlled by varying the scaffold modulus, from 0% to 15% bone strain increase. This strain increase is the magnitude reported to invoke bone's positive remodeling. Axial modulus was closely matched between titanium scaffolds and bone, ranging from 48-728 and 81-800 MPa, respectively, whereby scaffold axial modulus was within 2% of nominal target values. Fine control of multiaxial moduli resulted in transverse modulus that matched bone well; ranging from 42-648 and 47-585 MPa in scaffolds and bone respectively. The scaffold manufacturing material and method are already used in the orthopedic industry. This study has significant clinical implications as it enables the design of implants which positively harness bone's natural mechanoresponse and respect bone's mechanical anisotropy and heterogeneity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.