This paper presents a new tele-operated robotic chain for real-time ultrasound image acquisition and medical diagnosis. This system has been developed in the frame of the Mobile Tele-Echography Using an Ultralight Robot European Project. A light-weight six degrees-of-freedom serial robot, with a remote center of motion, has been specially designed for this application. It holds and moves a real probe on a distant patient according to the expert gesture and permits an image acquisition using a standard ultrasound device. The combination of mechanical structure choice for the robot and dedicated control law, particularly nearby the singular configuration allows a good path following and a robotized gesture accuracy. The choice of compression techniques for image transmission enables a compromise between flow and quality. These combined approaches, for robotics and image processing, enable the medical specialist to better control the remote ultrasound probe holder system and to receive stable and good quality ultrasound images to make a diagnosis via any type of communication link from terrestrial to satellite. Clinical tests have been performed since April 2003. They used both satellite or Integrated Services Digital Network lines with a theoretical bandwidth of 384 Kb/s. They showed the tele-echography system helped to identify 66% of lesions and 83% of symptomatic pathologies.
We report on the systematic characterization of photoluminescence (PL) lifetimes in NV − and NV 0 centers in 2-MeV H + -implanted type Ib diamond samples by means of a time-correlated single-photon counting (TCSPC) microscopy technique. A dipole-dipole resonant energy transfer model was applied to interpret the experimental results, allowing a quantitative correlation of the concentration of both native (single substitutional nitrogen atoms) and ion-induced (isolated vacancies) PL-quenching defects with the measured PL lifetimes. The TCSPC measurements were carried out in both frontal (i.e., laser beam probing the main sample surface along the same normal direction of the previously implanted ions) and lateral (i.e., laser beam probing the lateral sample surface orthogonally with respect to the same ion implantation direction) geometries. In particular, the latter geometry allowed a direct probing of the centers lifetime along the strongly nonuniform damage profiles of MeV ions in the crystal. The extrapolation of empirical quasiexponential decay parameters allowed the systematic estimation of the mean quantum efficiency of the centers as a function of intrinsic and ion-induced defect concentration, which is of direct relevance for the current studies on the use of diamond color centers for photonic applications.
A fine control of the variation of the refractive index as a function of structural damage is essential in the fabrication of diamond-based optical and photonic devices. We report here about the variation of the real part of the refractive index at λ = 632.8 nm in high-quality single-crystal diamond damaged with 2 and 3 MeV protons at low-medium fluences (10 13 -10 17 ions cm). After implanting the samples in 125 × 125 μm 2 areas with a raster scanning ion microbeam, the variation of optical thickness of the implanted regions was measured with laser interferometric microscopy. The results were analyzed with a model based on the specific damage profile. The technique allows the direct fabrication of optical structures in bulk diamond based on the localized variation of the refractive index, which will be explored in future works.
We present experimental results and numerical Finite Element analysis to
describe surface swelling due to the creation of buried graphite-like
inclusions in diamond substrates subjected to MeV ion implantation. Numerical
predictions are compared to experimental data for MeV proton and helium
implantations, performed with scanning ion microbeams. Swelling values are
measured with white light interferometric profilometry in both cases.
Simulations are based on a model which accounts for the through-the-thickness
variation of mechanical parameters in the material, as a function of ion type,
fluence and energy. Surface deformation profiles and internal stress
distributions are analyzed and numerical results are seen to adequately fit
experimental data. Results allow us to draw conclusions on structural damage
mechanisms in diamond for different MeV ion implantations.Comment: 15 pages, 4 figure
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.