Background: The concept of the vestibular implant is primarily to artificially restore the vestibular function in patients with a bilateral vestibular loss (BVL) by providing the central nervous system with motion information using electrical stimulation of the vestibular nerve. Our group initiated human trials about 10 years ago. Methods: Between 2007 and 2013, 11 patients with a BVL received a vestibular implant prototype providing electrodes to stimulate the ampullary branches of the vestibular nerve. Eye movements were recorded and analyzed to assess the effects of the electrical stimulation. Perception induced by electrical stimulation was documented. Results: Smooth, controlled eye movements were obtained in all patients showing that electrical stimulation successfully activated the vestibulo-ocular pathway. However, both the electrical dynamic range and the amplitude of the eye movements were variable from patient to patient. The axis of the response was consistent with the stimulated nerve branch in 17 out of the 24 tested electrodes. Furthermore, in at least 1 case, the elicited eye movements showed characteristics similar to those of compensatory eye movements observed during natural activities such as walking. Finally, diverse percepts were reported upon electrical stimulation (i.e., rotatory sensations, sound, tickling or pressure) with intensity increasing as the stimulation current increased. Conclusions: These results demonstrate that electrical stimulation is a safe and effective means to activate the vestibular system, even in a heterogeneous patient population with very different etiologies and disease durations. Successful tuning of this information could turn this vestibular implant prototype into a successful artificial balance organ.
The vestibulo-ocular reflex (VOR) shows frequency-dependent behavior. This study investigated whether the characteristics of the electrically evoked VOR (eVOR) elicited by a vestibular implant, showed the same frequency-dependency. Twelve vestibular electrodes implanted in seven patients with bilateral vestibular hypofunction (BVH) were tested. Stimuli consisted of amplitude-modulated electrical stimulation with a sinusoidal profile at frequencies of 0.5, 1, and 2 Hz. The main characteristics of the eVOR were evaluated and compared to the “natural” VOR characteristics measured in a group of age-matched healthy volunteers who were subjected to horizontal whole body rotations with equivalent sinusoidal velocity profiles at the same frequencies. A strong and significant effect of frequency was observed in the total peak eye velocity of the eVOR. This effect was similar to that observed in the “natural” VOR. Other characteristics of the (e)VOR (angle, habituation-index, and asymmetry) showed no significant frequency-dependent effect. In conclusion, this study demonstrates that, at least at the specific (limited) frequency range tested, responses elicited by a vestibular implant closely mimic the frequency-dependency of the “normal” vestibular system.
Vestibular implants are devices designed to rehabilitate patients with a bilateral vestibular loss (BVL). These patients lack a properly functioning vestibulo-ocular reflex (VOR), which impairs gaze stabilization abilities and results in an abnormal loss of visual acuity (VA) in dynamic situations (i.e., severely limiting the patient's ability to read signs or recognize faces while walking). We previously demonstrated that the VOR can be artificially restored in a group of BVL patients fitted with a prototype vestibular implant. This study was designed to investigate whether these promising results could be translated to a close-to-reality task, significantly improving VA abilities while walking. Six BVL patients previously implanted with a vestibular implant prototype participated in the experiments. VA was determined using Sloan letters displayed on a computer screen, in four conditions: (1) with the patient standing still without moving (static), (2) while the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned off (systemOFF), (3) while the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned on providing coherent motion information (systemONmotion), and (4) a “placebo” condition where the patient was walking on a treadmill at constant speed with the vestibular implant prototype turned on providing reversed motion information (systemONsham). The analysis (one-way repeated measures analysis of variance) revealed a statistically significant effect of the test condition [F(3, 12) = 30.5, p < 0.001]. Significant decreases in VA were observed with the systemOFF condition when compared to the static condition (Tukey post-hoc p < 0.001). When the vestibular implant was turned on, delivering pertinent motion information (systemONmotion) the VA improved to close to normal values. The improvement disappeared in the placebo condition (systemONsham) and VA-values also dropped significantly in this condition (Tukey post-hoc p < 0.001). These results are a significant step forward in the field, demonstrating for the first time in humans that gaze stabilization abilities can be restored with a vestibular implant prototype. The vestibular implant shows considerable promise of being the first-ever effective therapeutic alternative for patients with a BVL in the near future.
ObjectivePatients with bilateral vestibulopathy (BV) can still have residual “natural” function. This might interact with “artificial” vestibular implant input (VI-input). When fluctuating, it could lead to vertigo attacks. Main objective was to investigate how “artificial” VI-input is integrated with residual “natural” input by the central vestibular system. This, to explore (1) whether misalignment in the response of “artificial” VI-input is sufficiently counteracted by well-aligned residual “natural” input and (2) whether “artificial” VI-input is able to influence and counteract the response to residual “natural” input, to show feasibility of a “vestibular pacemaker.”Materials and methodsFive vestibular electrodes in four BV patients implanted with a VI were available. This involved electrodes with a predominantly horizontal response and electrodes with a predominantly vertical response. Responses to predominantly horizontal residual “natural” input and predominantly horizontal and vertical “artificial” VI-input were separately measured first. Then, inputs were combined in conditions where both would hypothetically collaborate or counteract. In each condition, subjects were subjected to 60 cycles of sinusoidal stimulation presented at 1 Hz. Gain, asymmetry, phase and angle of eye responses were calculated. Signal averaging was performed.ResultsCombining residual “natural” input and “artificial” VI-input resulted in an interaction in which characteristics of the resulting eye movement responses could significantly differ from those observed when responses were measured for each input separately (p < 0.0013). In the total eye response, inputs with a stronger vector magnitude seemed to have stronger weights than inputs with a lower vector magnitude, in a non-linear combination. Misalignment in the response of “artificial” VI-input was not sufficiently counteracted by well-aligned residual “natural” input. “Artificial” VI-input was able to significantly influence and counteract the response to residual “natural” input.ConclusionIn the acute phase of VI-activation, residual “natural” input and “artificial” VI-input interact to generate eye movement responses in a non-linear fashion. This implies that different stimulation paradigms and more complex signal processing strategies will be required unless the brain is able to optimally combine both sources of information after adaptation during chronic use. Next to this, these findings could pave the way for using the VI as “vestibular pacemaker.”
The purpose of this study was to evaluate whether it is possible to restore the high-frequency angular vestibulo-ocular reflex (aVOR) in patients suffering from a severe bilateral vestibulopathy (BV) and implanted with a vestibular implant prototype. Three patients (S1–3) participated in the study. They received a prototype vestibular implant with one to three electrode branches implanted in the proximity of the ampullary branches of the vestibular nerve. Five electrodes were available for electrical stimulation: one implanted in proximity of the left posterior ampullary nerve in S1, one in the left lateral and another one in the superior ampullary nerves in S2, and one in the right lateral and another one in the superior ampullary nerves in S3. The high-frequency aVOR was assessed using the video head impulse test (EyeSeeCam; EyeSeeTec, Munich, Germany), while motion-modulated electrical stimulation was delivered via one of the implanted vestibular electrodes at a time. aVOR gains were compared to control measurements obtained in the same patients when the device was not activated. In three out of the five tested electrodes the aVOR gain increased monotonically with increased stimulation strength when head impulses were delivered in the plane of the implanted canal. In these cases, gains ranging from 0.4 to values above 1 were measured. A “reversed” aVOR could also be generated when inversed stimulation paradigms were used. In most cases, the gain for excitatory head impulses was superior to that recorded for inhibitory head impulses, consistent with unilateral vestibular stimulation. Improvements of aVOR gain were generally accompanied by a concomitant decrease of corrective saccades, providing additional evidence of an effective aVOR. High inter-electrode and inter-subject variability were observed. These results, together with previous research, demonstrate that it is possible to restore the aVOR in a broad frequency range using motion-modulated electrical stimulation of the vestibular afferents. This provides additional encouraging evidence of the possibility of achieving a useful rehabilitation alternative for patients with BV in the near future.
The primary goal of the vestibular implant is to restore the vestibular function in patients with a disabling bilateral vestibular loss for whom there is currently no available treatment. The prototype developed by our team is a hybrid system consisting of a modified cochlear implant incorporating additional vestibular electrodes. Therefore, in addition of delivering sound information it is also capable of delivering motion information to the central nervous system using electrical stimulation. To date, thirteen patients have been implanted with such vestibular implant prototypes. For ethical reasons, only deaf ears were implanted and all patients experienced a clinical benefit from the hearing rehabilitation. The recent demonstration of partial restoration of the vestibulo-ocular and the vestibulo-collic reflexes in implanted patients suggests that gaze stabilization and postural control, fundamental functions of the balance system, can be artificially restored using a vestibular implant. This allows us to glimpse a useful clinical application in a near future. In parallel, we show how the vestibular implant provides a unique opportunity to explore the integration of the vestibular sensory input into the multisensory, multimodal balance system in humans, since it is able to selectively stimulate the vestibular system.
The mechanical performance of a typical surface course mixture, modified with two different plastic wastes, both via the wet and dry processes, was evaluated in this study. Water sensitivity, rutting resistance, stiffness modulus, and fatigue cracking resistance tests were used. The results obtained indicated that the polymer-modified mixtures showed similar or improved performance when compared with that of a conventional control mixture produced with a harder virgin grade bitumen, not always available, or available at higher costs, in several countries. Thus, modifying asphalt mixtures with these plastic wastes can be an economical and ecological alternative for paving works. Moreover, the mixtures produced via the dry process showed increased water sensitivity and stiffness modulus properties. This holds out new possibilities for use of polymer-modified mixtures, especially in developing countries, because it widens the possibility of using locally available bitumen, of variable quality, for producing mixtures with higher performance. This can be achieved at real scale with no major extra costs because the dry process does not require modification of typical asphalt plants
Introduction: The vestibular implant could become a clinically useful device in the near future. This study investigated the feasibility of restoring the high-frequency dynamic visual acuity (DVA) with a vestibular implant, using the functional Head Impulse Test (fHIT). Methods: A 72-year-old female, with bilateral vestibulopathy and fitted with a modified cochlear implant incorporating three vestibular electrodes (MED-EL, Innsbruck, Austria), was available for this study. Electrical stimulation was delivered with the electrode close to the lateral ampullary nerve in the left ear. The high-frequency DVA in the horizontal plane was tested with the fHIT. After training, the patient underwent six trials of fHIT, each with a different setting of the vestibular implant: (1) System OFF before stimulation; (2) System ON, baseline stimulation; (3) System ON, reversed stimulation; (4) System ON, positive stimulation; (5) System OFF, without delay after stimulation offset; and (6) System OFF, 25 min delay after stimulation offset. The percentage of correct fHIT scores for right and left head impulses were compared between trials. Results: Vestibular implant stimulation improved the high-frequency DVA compared to no stimulation. This improvement was significant for “System ON, baseline stimulation” (p = 0.02) and “System ON, positive stimulation” (p < 0.001). fHIT scores changed from 19 to 44% (no stimulation) to maximum 75–94% (System ON, positive stimulation). Conclusion: The vestibular implant seems capable of improving the high-frequency DVA. This functional benefit of the vestibular implant illustrates again the feasibility of this device for clinical use in the near future.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.