This paper presents a real-time capable graphics processing unit (GPU)-based ultrasound simulator suitable for medical education. The main focus of the simulator is to synthesize realistic looking ultrasound images in real-time including artifacts, which are essential for the interpretation of this data. The simulation is based on a convolution-enhanced ray-tracing approach and uses a deformable mesh model. Deformations of the mesh model are calculated using the PhysX engine. Our method advances the state of the art for real-time capable ultrasound simulators by following the path of the ultrasound pulse, which enables better simulation of ultrasound-specific artifacts. An evaluation of our proposed method in comparison with recent generative slicing-based strategies as well as real ultrasound images is performed. Hereby, a gelatin ultrasound phantom containing syringes filled with different media is scanned with a real transducer. The obtained images are then compared to images which are simulated using a slicing-based technique and our proposed method. The particular benefit of our method is the accurate simulation of ultrasound-specific artifacts, like range distortion, refraction and acoustic shadowing. Several test scenarios are evaluated regarding simulation time, to show the performance and the bottleneck of our method. While being computationally more intensive than slicing techniques, our simulator is able to produce high-quality images in real-time, tracing over 5000 rays through mesh models with more than 2 000 000 triangles of which up to 200 000 may be deformed each frame.
This study demonstrates that a microreactor setup with fast in-line reaction monitoring by Raman spectroscopy can be a highly efficient laboratory tool for kinetic studies and process development. Using a coaxial probe and commercial spectrometer to perform real-time measurements in the microchannel prevents the need for reaction quenching, sampling, and time-consuming off-line analysis methods such as GC or HPLC. A specially designed, temperature-controlled aluminum plate microreactor was developed and tested in the exothermic synthesis of 3-piperidino propionic acid ethyl ester by Michael addition. In-line measurements through a fused quartz screen in the reactor channel, which had an increasing cross-sectional area, allowed time-series kinetic data to be collected over nearly the full range of reaction conversions. An optimum flow rate range in which nearly ideal plug flow behavior can be assumed was identified. Furthermore, a time gradient was applied to the reactant flow rates, and the product concentration was simultaneously and repeatedly measured at various locations in the reactor channel. With this approach, the experiment duration and material consumption are significantly reduced relative to those of conventional steadystate experiments. Two hundred data points with residence times ranging from 0.3 to 49 s were collected in less than 1 h. Thus, this method can be used for the high-throughput screening of reaction parameters in a microreactor.
The monitoring of microbiological processes using Raman spectroscopy has gained in importance over the past few years. Commercial Raman spectroscopic equipment consists of a laser, spectrometer, and fiberoptic immersion probe in direct contact with the fermentation medium. To avoid possible sterilization problems and biofilm formation on the probe tip, a large-aperture Raman probe was developed. The design of the probe enables non-contact in-line measurements through glass vessels or inspection glasses of bioreactors and chemical reactors. The practical applicability of the probe was tested during yeast fermentations by monitoring the consumption of substrate glucose and the formation of ethanol as the product. Multiple linear regression models were applied to evaluate the Raman spectra. Reference values were determined by high-performance liquid chromatography. The relative errors of prediction for glucose and ethanol were 5 and 3%, respectively. The presented Raman probe allows simple adaption to a wide range of processes in the chemical, pharmaceutical, and biotechnological industries.
A new approach of combination of near-infrared (NIR) spectroscopy and refractometry was developed in this work to determine the concentration of alcohol and real extract in various beer samples. A partial least-squares (PLS) regression, as multivariate calibration method, was used to evaluate the correlation between the data of spectroscopy/refractometry and alcohol/extract concentration. This multivariate combination of spectroscopy and refractometry enhanced the precision in the determination of alcohol, compared to single spectroscopy measurements, due to the effect of high extract concentration on the spectral data, especially of nonalcoholic beer samples. For NIR calibration, two mathematical pretreatments (first-order derivation and linear baseline correction) were applied to eliminate light scattering effects. A sample grouping of the refractometry data was also applied to increase the accuracy of the determined concentration. The root mean squared errors of validation (RMSEV) of the validation process concerning alcohol and extract concentration were 0.23 Mas% (method A), 0.12 Mas% (method B), and 0.19 Mas% (method C) and 0.11 Mas% (method A), 0.11 Mas% (method B), and 0.11 Mas% (method C), respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.