Mobile measurement of particle number concentration (PN) in the exhaust of motor vehicles has recently become an integral part of emission legislation. Charge-based sensing techniques for the examination of PN, like Diffusion Charging (DC), represent a promising alternative to condensational particle counters (CPCs) as established PN sensors, because they enable to build robust, compact and energy efficient systems. However, due to the charging process, particle properties like size and morphology have a big impact on the sensor’s PN response. For particles of different size and shape we experimentally investigated those impacts using own-built charging-based sensors. The PN response of the DC sensor showed desired behavior for compact NaCl particles, but less satisfying behavior for combustion aerosol standard (CAST) particles, which is a widely used test aerosol for automotive applications. With a photoelectric charger, the PN response of CAST particles was significantly better.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.