Phantoms are common substitutes for soft tissues in biomechanical research and are usually tuned to match tissue properties using standard testing protocols at small strains. However, the response due to complex tool-tissue interactions can differ depending on the phantom and no comprehensive comparative study has been published to date, which could aid researchers to select suitable materials. In this work, gelatin, a common phantom in literature, and a composite hydrogel developed at Imperial College, were matched for mechanical stiffness to porcine brain, and the interactions during needle insertions within them were analyzed. Specifically, we examined insertion forces for brain and the phantoms; we also measured displacements and strains within the phantoms via a laser-based image correlation technique in combination with fluorescent beads. It is shown that the insertion forces for gelatin and brain agree closely, but that the composite hydrogel better mimics the viscous nature of soft tissue. Both materials match different characteristics of brain, but neither of them is a perfect substitute. Thus, when selecting a phantom material, both the soft tissue properties and the complex tool-tissue interactions arising during tissue manipulation should be taken into consideration. These conclusions are presented in tabular form to aid future selection.
Detailed finite element modelling of needle insertions into soft tissue phantoms encounters difficulties of large deformations, high friction, contact loading and material failure. This paper demonstrates the use of cohesive elements in high-resolution finite element models to overcome some of the issues associated with these factors. Experiments are presented enabling extraction of the strain energy release rate during crack formation. Using data from these experiments, cohesive elements are calibrated and then implemented in models for validation of the needle insertion process. Successful modelling enables direct comparison of finite element and experimental force-displacement plots and energy distributions. Regions of crack creation, relaxation, cutting and full penetration are identified. By closing the loop between experiments and detailed finite element modelling, a methodology is established which will enable design modifications of a soft tissue probe that steers through complex mechanical interactions with the surrounding material.
The mobility of soft tissue can cause inaccurate needle insertions. Particularly in steering applications that employ thin and flexible needles, large deviations can occur between pre-operative images of the patient, from which a procedure is planned, and the intra-operative scene, where a procedure is executed. Although many approaches for reducing tissue motion focus on external constraining or manipulation, little attention has been paid to the way the needle is inserted and actuated within soft tissue. Using our biologically inspired steerable needle, we present a method of reducing the disruptiveness of insertions by mimicking the burrowing mechanism of ovipositing wasps. Internal displacements and strains in three dimensions within a soft tissue phantom are measured at the needle interface, using a scanning laser-based image correlation technique. Compared to a conventional insertion method with an equally sized needle, overall displacements and strains in the needle vicinity are reduced by 30% and 41%, respectively. The results show that, for a given net speed, needle insertion can be made significantly less disruptive with respect to its surroundings by employing our biologically inspired solution. This will have significant impact on both the safety and targeting accuracy of percutaneous interventions along both straight and curved trajectories.
During minimally invasive surgical procedures, it is often important to deliver needles to particular tissue volumes. Needles, when interacting with a substrate, cause deformation and target motion. To reduce reliance on compensatory intra-operative imaging, a needle design and novel delivery mechanism is proposed. Three-dimensional finite element simulations of a multi-segment needle inserted into a pre-existing crack are presented. The motion profiles of the needle segments are varied to identify methods that reduce target motion. Experiments are then performed by inserting a needle into a gelatine tissue phantom and measuring the internal target motion using digital image correlation. Simulations indicate that target motion is reduced when needle segments are stroked cyclically and utilise a small amount of retraction instead of being held stationary. Results are confirmed experimentally by statistically significant target motion reductions of more than 8% during cyclic strokes and 29% when also incorporating retraction, with the same net insertion speed. By using a multi-segment needle and taking advantage of frictional interactions on the needle surface, it is demonstrated that target motion ahead of an advancing needle can be substantially reduced.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.