Under repetitive loading conditions, fractured vertebral bodies treated with kyphoplasty were initially taller, but because of a progressive loss of height during loading, the resulting constructs were shorter after 100,000 cycles than those treated with vertebroplasty.
X-STOP is the first interspinous process decompression device that was shown to be superior to nonoperative therapy in patients with neurogenic intermittent claudication secondary to spinal stenosis in the multicenter randomized study at 1 and 2 years. We present 4-year follow-up data on the X-STOP patients. Patient records were screened to identify potentially eligible subjects who underwent X-STOP implantation as part of the FDA clinical trial. The inclusion criteria for the trial were age of at least 50 years, leg, buttock, or groin pain with or without back pain relieved during flexion, being able to walk at least 50 feet and sit for at least 50 minutes. The exclusion criteria were fixed motor deficit, cauda equina syndrome, previous lumbar surgery or spondylolisthesis greater than grade I at the affected level. Eighteen X-STOP subjects participated in the study. The average follow-up was 51 months and the average age was 67 years. Twelve patients had the X-STOP implanted at either L3-4 or L4-5 levels. Six patients had the X-STOP implanted at both L3-4 and L4-5 levels. Six patients had a grade I spondylolisthesis. The mean preoperative Oswestry score was 45. The mean postoperative Oswestry score was 15. The mean improvement score was 29. Using a 15-point improvement from baseline Oswestry Disability Index score as a success criterion, 14 out of 18 patients (78%) had successful outcomes. Our results have demonstrated that the success rate in the X-STOP interspinous process decompression group was 78% at an average of 4.2 years postoperatively and are consistent with 2-year results reported by Zucherman et al previously and those reported by Lee et al. Our results suggest that intermediate-term outcomes of X-STOP surgery are stable over time as measured by the Oswestry Disability Index.
This first reported technique of posterior element vertebroplasty may increase the indications and success for patients with decreased BMD who seek an interspinous implant such as the X STOP. A possible role may exist in increasing the effectiveness of such devices. However, clinical trials have yet been performed. These results demonstrate that PMMA injection in the spinous processes is effective in increasing resistance to compressive forces in an X STOP model.
The bone mineral content is a strong predictor of the ultimate compressive load, while the percentage of the ultimate compressive load is a strong predictor of the cycles to failure for osteoporotic thoracic vertebral bodies.
This study was unable to identify a statistically significant difference in outcome between 1- and 2-level ProDisc arthroplasty patients in a cohort from a single center. The equality of clinical effectiveness between 1- and 2-level ProDisc has yet to be determined.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.