Background Accurate assessment of cardiac output (CO) is essential for the hemodynamic assessment of valvular heart disease. Estimation of oxygen consumption (VO2) and Thermodilution (TD) is employed in many cardiac catheterization laboratories (CCL) given the historically cumbersome nature of direct continuous VO2 measurement, the “gold standard” for this technique. A portable facemask device simplifies the direct continuous measurement of VO2, allowing for relatively rapid and continuous assessment of CO. Methods and Materials Thirty consecutive patients undergoing right heart catheterization had simultaneous determination of CO by both direct continuous and assumed VO2 and TD. Assessments were only made when a plateau of VO2 had occurred. All measurements of direct continuous and assumed VO2, as well as, TD CO were obtained in triplicate. Results Direct continuous VO2 CO and assumed VO2 CO correlated poorly (R= 0.57; ICC =0.59). Direct continuous VO2 CO and TD CO also correlated poorly (R= 0.51; ICC=0.60). Repeated direct continuous VO2 CO measurements were extremely correlated and reproducible [(R=0.93; ICC=0.96) suggesting that this was the most reliable measurement of CO. Conclusions CO calculated from direct continuous VO2 measurement varies substantially from both assumed VO2 and TD based CO, which are widely used in most CCL. These differences may significantly impact the CO measurements. Furthermore, continuous, rather than average, measurement of VO2 appears to give highly reproducible results.
Systemic artery-to-pulmonary artery fistula (SA-PAF) is a rare phenomenon that can resemble a filling defect on computed tomography angiography (CTA). SA-PAF can be due to congenital or acquired etiologies and can alter the hemodynamics of the pulmonary circulation, with the most serious reported complication being hemoptysis, requiring embolization. We describe a case of an unusual SA-PAF between the right inferior phrenic artery and the right lower lobe pulmonary artery that mimicked an unprovoked pulmonary embolus (PE) on standard CTA in a patient with cardiomyopathy. This SA-PAF was interpreted on CTA as PE due to the presence of a filling defect, revealing that not all filling defects are PE. SA-PAF should always be considered when the clinical context or the imaging findings are atypical, specifically with an isolated filling defect visualized in the inferior lower lobe pulmonary artery. The false-positive PE was the result of mixing of systemic non-opacified blood with opacified pulmonary arterial blood.
Disseminated peritoneal leiomyomatosis (DPL) is a rare variant of extrauterine leiomyomatosis with reported spontaneous and iatrogenic occurrences. It has been associated with hysterectomy and myomectomy. To our knowledge, reports have not yet substantiated occurrence following uterine artery embolization (UAE), which has become a routine minimally invasive alternative to surgery for the treatment of symptomatic leiomyomata. This report presents the case of a nulliparous premenopausal woman with no other contributory history who presented with DPL 3 years after UAE. The presentation of this patient suggests the potential for a causal relationship between UAE and DPL.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.