This paper presents a microstrip array antenna designed for a 2 × 2 Compressive Sensing Multiple-Input Multiple-Output (CS-MIMO) millimeter-wave radar operating at 37.5 GHz. The CS-MIMO linear array antenna is designed to obtain an optimal aperture by seeking a suitable random pattern for the antenna positions. Applying CS allows a considerable reduction in the number of antennas respect to a dense array based on the Nyquist criterion. In this study, we report all possible configurations of 2 × 2 CS-MIMO by placing antennas in random positions, plus their compression ratio. Finally, by selecting the proper design, we examine the experimental validation of the CS-MIMO antenna prototype by comparing measurements and simulations with a Standard MIMO (Std-MIMO) antenna prototype as a benchmark. The experimental results show that the angular resolution can be increased through a random array CS-MIMO by a factor of at least 2.9 respect to Std-MIMO while preserving the radar field of view.
With a low-energy accelerator, neither malfunctions nor electromagnetic interferences were detected radiating the ICDs at doses usually reaching the ICD pocket during radiotherapy sessions. In this context, magnet application to avoid oversensing and inappropriate therapy seems, therefore, useless.
In this paper, we assess the features of a rectangular constellation of four anchors on the position estimation accuracy of a mobile tag, operating under the IEEE 802.15.4 specifications. Each anchor implements a smart antenna with eight switched beams, which is capable to collect Received Signal Strength Indicator (RSSI) data, exploited to estimate the mobile tag position within a room. We also aim at suggesting a deployment criterion, providing the discussion of the best trade-off between system complexity and positioning accuracy. The assessment validation was conducted experimentally by implementing anchor constellations with different mesh sizes in the same room. Mean accuracies spanning from 0.32 m to 0.7 m on a whole 7.5 m × 6 m room were found by varying the mesh area from 1.19 m2 to 17 m2, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.