BackgroundTo analyze voxel-wise correlation between cerebral blood flow (CBF) measured using ASL-MRI and cognition in patients with Alzheimer’s disease (AD).MethodsForty-one patients diagnosed with AD or mild cognitive impairment due to AD were recruited for this study. CBF images were obtained using ASL-MRI (n = 41) with a post-labeling delay (PLD) of 1.5 and 2.5 s (PLD1.5 and PLD2.5, respectively) using a 3 T scanner, in addition to brain perfusion SPECT with N-isopropyl-4-[I-123]iodoamphetamine (n = 28). Voxel-based analyses were performed for ASL-MRI and SPECT using Mini-Mental State Examination (MMSE) scores as covariates. Differences in CBF between PLD1.5 and PLD2.5 were assessed using a paired t-test with SPM12.ResultsSignificant positive correlations were observed between MMSE scores and CBF at PLD1.5 in the right posterior cingulate cortex (PCC), and both temporo-parietal association cortexes. At PLD2.5, significant positive correlations were determined for MMSE scores and CBF in the superior parietal lobule and the right temporo-parietal association cortex. SPECT showed significant positive correlations in the PCC and both temporo-parietal association cortexes (right-side dominant). PLD1.5 showed significantly higher CBF than PLD2.5 in the proximal areas of vascular territories of the anterior, middle, and posterior cerebral arteries.ConclusionsSignificant positive correlations in CBF, measured with both ASL-MRI and SPECT, with cognition were found in the PCC and temporo-parietal association cortexes. PLD1.5 and PLD2.5 showed similar correlations with cognition, although the CBF images had significant differences.
BackgroundRecent developments in hardware and software for PET technologies have resulted in wide variations in basic performance. Multicentre studies require a standard imaging protocol and SUV harmonization to reduce inter- and intra-scanner variability in the SUV. The Japanese standardised uptake value (SUV) Harmonization Technology (J-Hart) study aimed to determine the applicability of vendor-neutral software on the SUV derived from positron emission tomography (PET) images. The effects of SUV harmonization were evaluated based on the reproducibility of several scanners and the repeatability of an individual scanner.Images were acquired from 12 PET scanners at nine institutions. PET images were acquired over a period of 30 min from a National Electrical Manufacturers Association (NEMA) International Electrotechnical Commission (IEC) body phantom containing six spheres of different diameters and an 18F solution with a background activity of 2.65 kBq/mL and a sphere-to-background ratio of 4. The images were reconstructed to determine parameters for harmonization and to evaluate reproducibility. PET images with 2-min acquisition × 15 contiguous frames were reconstructed to evaluate repeatability. Various Gaussian filters (GFs) with full-width at half maximum (FWHM) values ranging from 1 to 15 mm in 1-mm increments were also applied using vendor-neutral software. The SUVmax of spheres was compared with the reference range proposed by the Japanese Society of Nuclear Medicine (JSNM) and the digital reference object (DRO) of the NEMA phantom. The coefficient of variation (CV) of the SUVmax determined using 12 PET scanners (CVrepro) was measured to evaluate reproducibility. The CV of the SUVmax determined from 15 frames (CVrepeat) per PET scanner was measured to determine repeatability.ResultsThree PET scanners did not require an additional GF for harmonization, whereas the other nine required additional FWHM values of GF ranging from 5 to 9 mm. The pre- and post-harmonization CVrepro of six spheres were (means ± SD) 9.45% ± 4.69% (range, 3.83–15.3%) and 6.05% ± 3.61% (range, 2.30–10.7%), respectively. Harmonization significantly improved reproducibility of PET SUVmax (P = 0.0055). The pre- and post-harmonization CVrepeat of nine scanners were (means ± SD) 6.59% ± 1.29% (range, 5.00–8.98%) and 4.88% ± 1.64% (range, 2.65–6.72%), respectively. Harmonization also significantly improved the repeatability of PET SUVmax (P < 0.0001).ConclusionsHarmonizing SUV using vendor-neutral software produced SUVmax for 12 scanners that fell within the JSNM reference range of a NEMA body phantom and improved SUVmax reproducibility and repeatability.
BackgroundThe goal of this study was to evaluate the performance of the Celesteion positron emission tomography/computed tomography (PET/CT) scanner, which is characterized by a large-bore and time-of-flight (TOF) function, in accordance with the NEMA NU-2 2012 standard and version 2.0 of the Japanese guideline for oncology fluorodeoxyglucose PET/CT data acquisition protocol. Spatial resolution, sensitivity, count rate characteristic, scatter fraction, energy resolution, TOF timing resolution, and image quality were evaluated according to the NEMA NU-2 2012 standard. Phantom experiments were performed using 18F-solution and an IEC body phantom of the type described in the NEMA NU-2 2012 standard. The minimum scanning time required for the detection of a 10-mm hot sphere with a 4:1 target-to-background ratio, the phantom noise equivalent count (NECphantom), % background variability (N 10mm), % contrast (Q H,10mm), and recovery coefficient (RC) were calculated according to the Japanese guideline.ResultsThe measured spatial resolution ranged from 4.5- to 5-mm full width at half maximum (FWHM). The sensitivity and scatter fraction were 3.8 cps/kBq and 37.3%, respectively. The peak noise-equivalent count rate was 70 kcps in the presence of 29.6 kBq mL−1 in the phantom. The system energy resolution was 12.4% and the TOF timing resolution was 411 ps at FWHM. Minimum scanning times of 2, 7, 6, and 2 min per bed position, respectively, are recommended for visual score, noise-equivalent count (NEC)phantom, N 10mm, and the Q H,10mm to N 10mm ratio (QNR) by the Japanese guideline. The RC of a 10-mm-diameter sphere was 0.49, which exceeded the minimum recommended value.ConclusionsThe Celesteion large-bore PET/CT system had low sensitivity and NEC, but good spatial and time resolution when compared to other PET/CT scanners. The QNR met the recommended values of the Japanese guideline even at 2 min. The Celesteion is therefore thought to provide acceptable image quality with 2 min/bed position acquisition, which is the most common scan protocol in Japan.
Our results demonstrate the difference in NaF-18 uptake between cancellous and cortical bones, which may explain differences in uptake by location. NaF-18 uptake does not appear to be strongly correlated with bone density, but rather with bone turnover and blood flow.
Purpose Peptide receptor radionuclide therapy (PRRT) with 177Lu-DOTA0-Tyr3-octreotate (177Lu-DOTATATE) is one of the most reliable treatments for unresectable, progressive neuroendocrine tumors (NETs) with somatostatin receptor expression. We have, for the first time, reported the results of the tolerability, safety, pharmacokinetics, dosimetry, and efficacy of this treatment for Japanese patients with NET. Methods Patients with unresectable, somatostatin receptor scintigraphy (SRS)-positive NETs were enrolled in this phase I clinical trial. They were treated with 29.6 GBq of 177Lu-DOTATATE (four doses of 7.4 GBq) combined with amino acid solution infusion plus octreotide long-acting release (LAR) 30 mg. The primary objective of this study was to evaluate the tolerability, safety, pharmacokinetics, and dosimetry of a single administration of this treatment in patients with SRS-positive NETs. Results Six Japanese patients (three men and three women; mean age 61.5 years; range 50–70 years) with SRS-positive unresectable NETs were recruited. 177Lu-DOTATATE was eliminated from the blood in a two-phase manner. Cumulative urinary excretion of radioactivity was 60.1% (range 49.0%–69.8%) within the initial 6 h. The cumulative renal absorbed dose for 29.6 GBq of 177Lu-DOTATATE was 16.8 Gy (range 12.0–21.2 Gy), and the biological effective dose was 17.0 Gy (range 12.2–21.5 Gy). Administration of 177Lu-DOTATATE was well tolerated, with no dose-limiting toxicities. Grade 3 lymphopenia occurred in two (33.3%) cases, but there were no other severe toxicities. Four patients achieved partial response (objective response rate, 66.7%), one patient had stable disease, and one patient had progressive disease. Conclusion PRRT with 177Lu-DOTATATE was well-tolerated and showed good outcomes in Japanese patients with unresectable NETs. Peptide receptor radionuclide therapy, 177Lu-DOTA0-Tyr3-octreotate .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.