Functional spinopelvic parameters are crucial for describing spinal alignment (SA), but this is susceptible to variation. Anatomically fixed pelvic shape is defined by the parameters pelvic radius (PR), pelvic incidence (PI), and sacral table angle (STA). In patients with lumbosacral transitional vertebrae (LSTV), the spinopelvic alignment may be altered by changes of these parameters and influences of SA. There have been no reports studying the relation between LSTV, four (4 LV) and six (6 LV) lumbar vertebrae, and fixed anatomical spinopelvic parameters. A retrospective analysis of 819 abdomen–pelvis CT scans was performed, identifying 53 patients with LSTV. In a matched-pair analysis, we analyzed the influence of LSTV and the subgroups 4 LV (n = 9) and 6 LV (n = 11) on PR, PI, and STA. LSTV were classified according to Castellvi classification. In patients with 6 LV, measurement points at the superior endplates of S1 and S2 were compared. The prevalence of LSTV was 6.5% (53/819), 6 LV was 1.3% (11/819), and 4 LV was 1.1% (9/819) in our study population. PI significantly increased (p < 0.001), STA significantly decreased (p < 0.001), and PR (p = 0.051) did not differ significantly in the LSTV group (n = 53). Similar findings were observed in the 4 LV subgroup, with an increase in PI (p < 0.021), decrease in STA (p < 0.011), and no significant difference in PR (p < 0.678). The same results were obtained in the 6 LV subgroup at measuring point S2 (true S1) PI (p = 0.010), STA (p = 0.004), and PR (p = 0.859), but not at measuring point S1 (true L6). Patients with LSTV, 4 LV, and 6 LV showed significant differences in PI and STA compared to the matched control group. PR showed no significant differences. The altered spinopelvic anatomy in LSTV patients need to be reflected in preoperative planning rebalancing the sagittal SA.
Introduction There is a paucity of literature regarding serum C-reactive protein (CRP) in the evaluation of a shoulder periprosthetic joint infection (PJI). The purpose of the current study was to establish cutoff values for diagnosing shoulder PJI and evaluate the influence of the type of infecting microorganism and the classification subgroups according to last proposed International Consensus Meeting (ICM) criteria on the CRP level. Materials and methods A retrospective analysis of all 136 patients, who underwent septic or aseptic revision shoulder arthroplasty in our institution between January 2010 and December 2019, was performed. Shoulder PJI was defined according to the last proposed definition criteria of the ICM. Serum CRP levels were compared between infected and non-infected cases, between infection subgroups, as well as between different species of infecting microorganisms. A receiver-operating characteristic (ROC) analysis was performed to display sensitivity and specificity of serum CRP level for shoulder PJI. Results A total of 52 patients (38%) were classified as infected, 18 meeting the criteria for definitive infection, 26 for probable infection and 8 for possible infection. According to the ROC curve, an optimized serum CRP threshold of 7.2 mg/l had a sensitivity of 69% and specificity of 74% (area under curve = 0.72). Patients with definitive infection group demonstrated significantly higher median serum CRP levels (24.3 mg/l), when compared to probable, possible infection groups and PJI unlikely group (8 mg/l, 8.3 mg/l, 3.6 mg/l, respectively, p < 0.05). The most common isolated microorganism was Cutibacterium acnes in 25 patients (48%) followed by coagulase-negative staphylococci (CNS) in 20 patients (39%). Patients with a PJI caused by high-virulent microorganisms had a significantly higher median serum CRP level compared to patients with PJI caused by low-virulent microorganisms (48 mg/l vs. 11.3 mg/l, p = 0.04). Conclusions Serum CRP showed a low sensitivity and specificity for the diagnosis of shoulder PJI, even applying cutoffs optimized by receiver-operating curve analysis. Low-virulent microorganisms and patients with probable and possible infections are associated with lower CRP levels compared to patients with definitive infection and infections caused by high-virulent microorganisms. Level of evidence Diagnostic Level III.
This study evaluated the reliability and comprehensiveness of the Unified classification system (UCPF), Wright & Cofield, Worland and Kirchhoff classifications and related treatment recommendations for periprosthetic shoulder fractures (PPSFx). Two shoulder arthroplasty specialists (experts) and two orthopaedic residents (non-experts) assessed 20 humeral-sided and five scapula-sided cases of PPSFx. We used the unweighted Cohen’s Kappa (κ) for measuring the intra-observer reliability and Krippendorff’s alpha (α) for measuring the inter-observer reliability. The inter-rater reliabilities for the Wright & Cofield and Worland classifications were substantial for all groups. The expert and non-expert groups for UCPF also showed substantial inter-rater agreement. The all-rater group for the UCPF and the expert and non-expert group for the Kirchhoff classification revealed moderate inter-rater reliability. For the Kirchhoff classification, only fair inter-rater reliability was found for the non-expert group. Almost perfect intra-rater reliability was measured for all groups of the Wright & Cofield classification and the all-rater and expert groups of the UCPF. All groups of the Kirchhoff and Worland classifications and the group of non-experts for the UCPF had substantial intra-rater reliabilities. Regarding treatment recommendations, substantial inter-rater and moderate intra-rater reliabilities were found. Simple classification systems for PPSFx (Wright & Cofield, Worland) show the highest inter- and intra-observer reliability but lack comprehensiveness as they fail to describe scapula-sided fractures. The complex Kirchhoff classification shows limited reliability. The UCPF seems to offer an acceptable combination of comprehensiveness and reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.