Aims. In March 2008, the APEX facility instrument was installed on the telescope at the site of Lliano Chajnantor in northern Chile. The main objective of the paper is to introduce the new instrument to the radio astronomical community. It describes the hardware configuration and presents some initial results from the on-sky commissioning. Methods. The heterodyne instrument covers frequencies between 211 GHz and 1390 GHz divided into four bands. The first three bands are sideband-separating mixers operating in a single sideband mode and based on superconductor-insulator-superconductor (SIS) tunnel junctions. The fourth band is a hot-electron bolometer, waveguide balanced mixer. All bands are integrated in a closedcycle temperature-stabilized cryostat and are cooled to 4 K. Results. We present results from noise temperature, sideband separation ratios, beam, and stability measurements performed on the telescope as a part of the receiver technical commissioning. Examples of broad extragalactic lines are also included.
Context. Molecular oxygen, O 2 , has been expected historically to be an abundant component of the chemical species in molecular clouds and, as such, an important coolant of the dense interstellar medium. However, a number of attempts from both ground and from space have failed to detect O 2 emission. Aims. The work described here uses heterodyne spectroscopy from space to search for molecular oxygen in the interstellar medium. Methods. The Odin satellite carries a 1.1 m sub-millimeter dish and a dedicated 119 GHz receiver for the ground state line of O 2 . Starting in 2002, the star forming molecular cloud core ρ Oph A was observed with Odin for 34 days during several observing runs. Results. We detect a spectral line at v LSR = +3.5 km s −1 with ∆v FWHM = 1.5 km s −1 , parameters which are also common to other species associated with ρ Oph A. This feature is identified as the O 2 (N J = 1 1 −1 0 ) transition at 118 750.343 MHz. Conclusions. The abundance of molecular oxygen, relative to H 2 , is 5 × 10 −8 averaged over the Odin beam. This abundance is consistently lower than previously reported upper limits.
Abstract. The Sub-millimetre and Millimetre Radiometer (SMR) is the main instrument on the Swedish, Canadian, Finnish and French spacecraft Odin. It consists of a 1.1 metre diameter telescope with four tuneable heterodyne receivers covering the ranges 486−504 GHz and 541−581 GHz, and one fixed at 118.75 GHz together with backends that provide spectral resolution from 150 kHz to 1 MHz. This Letter describes the Odin radiometer, its operation and performance with the data processing and calibration described in Paper II.
Context. We describe the new SEPIA (Swedish-ESO PI Instrument for APEX) receiver, which was designed and built by GARD OSO in collaboration with ESO. It was installed and commissioned at the APEX telescope during 2015 with an ALMA Band 5 receiver channel and updated with a new frequency channel (ALMA Band 9) in February 2016. Aims. This manuscript provides a reference for observers who use the SEPIA receiver in terms of the hardware description, optics and performance as well as the commissioning results. Methods. Out of three available receiver cartridge positions in SEPIA, the two current frequency channels, corresponding to ALMA Band 5, the RF band 158-211 GHz, and Band 9, the RF band 600-722 GHz, provide state-of-the-art dual polarization receivers. The Band 5 frequency channel uses 2SB SIS mixers with an average SSB noise temperature around 45 K with IF (intermediate frequency) band 4-8 GHz for each sideband providing total 4 × 4 GHz IF band. The Band 9 frequency channel uses DSB SIS mixers with a noise temperature of 75-125 K with IF band 4-12 GHz for each polarization.Results. Both current SEPIA receiver channels are available to all APEX observers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.