A large body of evidence attests that quality programs developed around the analytical phase of the total testing process would only produce limited improvements, since the large majority of errors encountered in clinical laboratories still prevails within extra-analytical areas of testing, especially in manually intensive preanalytical processes. Most preanalytical errors result from system flaws and insufficient audit of the operators involved in specimen collection and handling responsibilities, leading to an unacceptable number of unsuitable specimens due to misidentification, in vitro hemolysis, clotting, inappropriate volume, wrong container or contamination from infusive routes. Detection and management of unsuitable samples are necessary to overcome this variability. The present document, issued by the Italian Inter-society SIBioC-SIMeL-CISMEL (Society of Clinical Biochemistry and Clinical Molecular Biology-Italian Society of Laboratory Medicine-Italian Committee for Standardization of Hematological and Laboratory Methods) Study Group on Extra-analytical Variability, reviews the major causes of unsuitable specimens in clinical laboratories, providing consensus recommendations for detection and management.
Sickle cell anaemia (SCA) is the consequence of abnormal haemoglobin production due to an inherited point mutation in the β‐globin gene. The resulting haemoglobin tetramer is poorly soluble when deoxygenated, and when this is prolonged, intracellular gelation of sickle haemoglobin occurs, followed by haemoglobin polymerisation. If many cycles of sickling and unsickling occur, the red cell membrane will be disrupted leading to haemolysis and vaso‐occlusive events. Recent studies have also shown that leucocyte adhesion molecules and nitric oxide (NO) depletion are involved in endothelial damage. New insights in SCA pathophysiology and vascular biology have shown that cell‐derived microparticle (MP) generation is also involved in the vaso‐occlusion. Endothelial damage is perpetuated by impaired production or increased consumption of protective modulators such as protein C, protein S and NO. New therapeutic interventions should address these aspects of SCA pathogenesis. To date, the only US‐FDA‐approved therapy to prevent painful vaso‐occulsive episodes is hydroxyurea that reduces haemoglobin polymerisation in sickle cells by increasing the production of foetal haemoglobin and L‐glutamine. However, several new drugs have been tested in the last years in randomised clinical trials. We here report an update on the current status of knowledge on SCA.
In the two cohorts analyzed, the anti-IMPDH2 response as a component of the anti-RR response is much more prominent in the Italian cohort. The reason for the difference between the US and Italian cohorts is unclear but it possibly illustrates the heterogeneity in response and the overall negative correlation between the production of these autoantibodies and response to IFN/R therapy. Patients with high titer anti-RR antibodies are either relapsers (Italian) or non-responders/relapsers (US).
Our study partially confirms previous data on the association between MPV or RDW and AMI. The inclusion of these parameters along with other conventional cardiac biomarkers might be a valuable perspective when evaluating patients with suspected AMI, although gender differences should be taken in account.
The use of contrast media such as organic iodine molecules and gadolinium contrast agents is commonplace in diagnostic imaging. Although there is widespread perception that side effects and drug interactions may be the leading problems caused by these compounds, various degrees of interference with some laboratory tests have been clearly demonstrated. Overall, the described interference for iodinate contrast media include inappropriate gel barrier formation in blood tubes, the appearance of abnormal peaks in capillary zone electrophoresis of serum proteins, and a positive bias in assessment of cardiac troponin I with one immunoassay. The interference for gadolinium contrast agents include negative bias in calcium assessment with ortho-cresolphthalein colorimetric assays and occasional positive bias using some Arsenazo reagents, negative bias in measurement of angiotensin converting enzyme (ACE) and zinc (colorimetric assay), as well as positive bias in creatinine (Jaffe reaction), total iron binding capacity (TIBC, ferrozine method), magnesium (calmagite reagent) and selenium (mass spectrometry) measurement. Interference has also been reported in assessment of serum indices, pulse oximetry and methaemoglobin in samples of patients receiving Patent Blue V. Under several circumstances the interference was absent from manufacturer-supplied information and limited to certain type of reagents and/or analytes, so that local verification may be advisable to establish whether or not the test in use may be biased. Since the elimination half-life of these compounds is typically lower than 2 h, blood collection after this period may be a safer alternative in patients who have received contrast media for diagnostic purposes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.