The peripheral benzodiazepine receptor (PBR) is upregulated on activated microglia and macrophages and thereby is a useful biomarker of inflammation. We developed a novel PET radioligand, [ 11 C]PBR28, that was able to image and quantify PBRs in healthy monkeys and in a rat model of stroke. The objective of this study was to evaluate the ability of [ 11 C]PBR28 to quantify PBRs in brain of healthy human subjects. Twelve subjects had PET scans of 120 to 180 min duration as well as serial sampling of arterial plasma to measure the concentration of unchanged parent radioligand. One-and two-tissue compartmental analyses were performed. To obtain stable estimates of distribution volume, which is a summation of B max /K D and nondisplaceable activity, 90 min of brain imaging was required. Distribution volumes in human were only ∼5% of those in monkey. This comparatively low amount of receptor binding required a two-rather than a one-compartment model, suggesting that nonspecific binding was a sizeable percentage compared to specific binding. The time-activity curves in two of the twelve subjects appeared as if they had no PBR binding -i.e., rapid peak of uptake and fast washout from brain. The cause(s) of these unusual findings are unknown, but both subjects were also found to lack binding to PBRs in peripheral organs such as lung and kidney. In conclusion, with the exception of those subjects who appeared to have no PBR binding, [ 11 C]PBR28 is a promising ligand to quantify PBRs and localize inflammation associated with increased densities of PBRs.
We sought to develop (11)C-labeled ligands for sensitive imaging of brain peripheral benzodiazepine receptors (PBR) in vivo. Two aryloxyanilides with high affinity for PBR were identified and synthesized, namely, N-acetyl- N-(2-methoxycarbonylbenzyl)-2-phenoxyaniline ( 3, PBR01) and N-(2-methoxybenzyl)- N-(4-phenoxypyridin-3-yl)acetamide ( 10, PBR28). 3 was hydrolyzed to 4, which was esterified with [ (11)C]iodomethane to provide [ (11)C] 3. The O-desmethyl analogue of 10 was converted into [ (11)C] 10 with [ (11)C]iodomethane. [ (11)C] 3 and [ (11)C] 10 were each injected into monkey to assess their brain kinetics with positron emission tomography (PET). After administration of either radioligand there was moderately high brain uptake of radioactivity. Receptor blocking and displacement experiments showed that a high proportion of this radioactivity was bound specifically to PBR. In monkey and rat, 3 and 10 were rapidly metabolized by ester hydrolysis and N-debenzylation, respectively, each to a single polar radiometabolite. [ (11)C] 3 and [ (11)C] 10 are effective for imaging PBR in monkey brain. [ (11)C] 10 especially warrants further evaluation in human subjects.
Objectives-Peripheral benzodiazepine receptors (PBRs) are upregulated on activated microglia and are thereby biomarkers of neuroinflammation. We developed a PET ligand with an aryloxyanilide structure, [O-methyl-11 C]N-acetyl-N-(2-methoxybenzyl)-2-phenoxy-5-pyridinamine ([ 11 C] PBR28), to image PBRs. The objectives of the current study were to evaluate kinetics of brain uptake, and the influence of the peripheral binding on the arterial input function in rhesus monkey.Methods-Brain (baseline: n=6, blocking: n=1) and whole-body PET imaging (baseline: n=3, blocking: n=1) of [ 11 C]PBR28 were performed with the measurement of radiometabolite-corrected arterial input function in all brain and two whole body scans.Results-Saturating doses of nonradioactive PBR ligands markedly increased [ 11 C]PBR28 in plasma (∼400% increase) and brain (∼200%) at 2 min by displacing radioligand from PBRs in peripheral organs. Brain uptake of radioactivity peaked in baseline scans at ∼40 min after injection of [ 11 C]PBR28 and was high (∼300% standardized uptake value). The images showed no receptorfree region that could be used for reference tissue analysis. Thus, quantitation of receptor density required measurement of parent radioligand in arterial plasma. Nondisplaceable uptake was estimated from the blocked scans and was only ∼5% of total distribution volume measured under baseline conditions. Distribution volume of [ 11 C]PBR28 was stably determined within 110 min of scanning.Conclusions-Regional brain uptake of [ 11 C]PBR28 in monkey could be quantified as a value proportional to the density of receptors -namely, as equilibrium distribution volume. [ 11 C]PBR28 had high levels of specific binding in brain and should provide a sensitive measure of changes in PBRs.
A Geiger-mode avalanche photodiode (Si-PM) is a promising photodetector for PET, especially for use in a magnetic resonance imaging (MRI) system, because it has high gain and is less sensitive to a static magnetic field. We developed a Si-PM-based depth-of-interaction (DOI) PET system for small animals. Hamamatsu 4 × 4 Si-PM arrays (S11065-025P) were used for its detector blocks. Two types of LGSO scintillator of 0.75 mol% Ce (decay time: ∼45 ns; 1.1 mm × 1.2 mm × 5 mm) and 0.025 mol% Ce (decay time: ∼31 ns; 1.1 mm × 1.2 mm × 6 mm) were optically coupled in the DOI direction to form a DOI detector, arranged in a 11 × 9 matrix, and optically coupled to the Si-PM array. Pulse shape analysis was used for the DOI detection of these two types of LGSOs. Sixteen detector blocks were arranged in a 68 mm diameter ring to form the PET system. Spatial resolution was 1.6 mm FWHM and sensitivity was 0.6% at the center of the field of view. High-resolution mouse and rat images were successfully obtained using the PET system. We confirmed that the developed Si-PM-based PET system is promising for molecular imaging research.
Elevated levels of peripheral benzodiazepine receptors (PBR) are associated with activated microglia in their response to inflammation. Hence, PBR imaging in vivo is valuable for investigating brain inflammatory conditions. Sensitive, easily prepared, and readily available radioligands for imaging with positron emission tomography (PET) are desirable for this purpose. We describe a new 18F-labeled PBR radioligand, namely [18F]N-fluoroacetyl-N-(2,5-dimethoxybenzyl)-2-phenoxyaniline ([18F]9). [18F]9 was produced easily through a single and highly efficient step, the reaction of [18F]fluoride ion with the corresponding bromo precursor, 8. Ligand 9 exhibited high affinity for PBR in vitro. PET showed that [18F]9 was avidly taken into monkey brain and gave a high ratio of PBR-specific to nonspecific binding. [18F]9 was devoid of defluorination in rat and monkey and gave predominantly polar radiometabolite(s). In rat, a low level radiometabolite of intermediate lipophilicity was identified as [18F]2-fluoro-N-(2-phenoxyphenyl)acetamide ([18F]11). [18F]9 is a promising radioligand for future imaging of PBR in living human brain.
Peripheral benzodiazepine receptors (PBRs) are upregulated on activated microglia and are, thereby, biomarkers of cellular inflammation in brain. We recently developed two PET ligands with an aryloxyanilide structure to image PBRs and now evaluate the kinetics of these radiotracers in monkey to determine whether they are suitable to explore in human. Baseline and receptor-blocking scans were performed with [(11)C]PBR01 and [(18)F]PBR06 in conjunction with serial measurements of the arterial plasma concentration of parent radiotracer separated from radiometabolite. We used brain and plasma data with compartmental modeling to calculate regional brain distribution volume, which is equal to the ratio at equilibrium of the concentration of radioligand in brain to that of plasma. The distribution volume of [(11)C]PBR01 was inaccurately estimated in the baseline scans, possibly because of the short half-life of (11)C or the presence of radiometabolite in brain. In contrast, the distribution volume of [(18)F]PBR06 was stably determined within 200 min of scanning, and nondisplaceable uptake was only approximately 10% of total brain uptake. [(18)F]PBR06 is promising for use in human because brain activity could be quantified with standard compartmental models and showed higher ratios ( approximately 10:1) of specific to nonspecific uptake. A critical factor for human use will be whether the tracer has adequately fast wash out from brain relative to the half-life of the radionuclide to obtain stable values of distribution volume.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.