Deformable image registration (DIR) has recently become commercially available in the field of radiotherapy. However, there was no detailed information regarding the use of DIR software at each medical institution. Thus, in this study, we surveyed the status of the clinical use of DIR software for radiotherapy in Japan. The Japan Society of Medical Physics and the Japanese Society for Radiation Oncology mailing lists were used to announce this survey. The questionnaire was created by investigators working under the research grant of the Japanese Society for Radiation Oncology (2017–2018) and intended for the collection of information regarding the use of DIR in radiotherapy. The survey was completed by 161 institutions in Japan. The survey results showed that dose accumulation was the most frequent purpose for which DIR was used in clinical practice (73%). Various commissioning methods were performed, although they were not standardized. Qualitative evaluation with actual patient images was the most commonly used method (28%), although 30% of the total number of responses (42% of institutions) reported that they do not perform commissioning. We surveyed the current status of clinical use of DIR software for radiotherapy in Japan for the first time. Our results indicated that a certain number of institutions used DIR software for clinical practice, and various commissioning methods were performed, although they were not standardized. Taken together, these findings highlight the need for a technically unified approach for commissioning and quality assurance for the use of DIR software in Japan.
The Japan Clinical Oncology Group–Radiation Therapy Study Group (JCOG-RTSG) has initiated several multicenter clinical trials for high-precision radiotherapy, which are presently ongoing. When conducting multi-center clinical trials, a large difference in physical quantities, such as the absolute doses to the target and the organ at risk, as well as the irradiation localization accuracy, affects the treatment outcome. Therefore, the differences in the various physical quantities used in different institutions must be within an acceptable range for conducting multicenter clinical trials, and this must be verified with medical physics consideration. In 2011, Japan’s first Medical Physics Working Group (MPWG) in the JCOG-RTSG was established to perform this medical-physics-related verification for multicenter clinical trials. We have developed an auditing method to verify the accuracy of the absolute dose and the irradiation localization. Subsequently, we credentialed the participating institutions in the JCOG multicenter clinical trials that were using stereotactic body radiotherapy (SBRT) for lungs, intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for several disease sites, and proton beam therapy (PT) for the liver. From the verification results, accuracies of the absolute dose and the irradiation localization among the participating institutions of the multicenter clinical trial were assured, and the JCOG clinical trials could be initiated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.