This retrospective study analyzed clinical outcomes of monolithic zirconia restorations (MZRs) and factors related to restoration success. Patient records were searched to identify those provided MZRs (Cercon ht) for premolars or molars between April 2012 and March 2016. All MZRs were placed according to a standardized protocol. Kaplan-Meier analysis was used to assess MZR performance and failure after recall appointments at 1 year or later. In total, 101 patients received 148 MZRs. Mean duration of follow-up was 25.0 ± 9.9 months. Six MZRs required replacement: three because of pulpal complications, one because of root fracture of an abutment tooth, one because of restoration fracture, and one because the tooth was used as an abutment tooth for a fixed partial denture after root fracture of an adjacent tooth. The cumulative MZR survival (success) rate at 3.5 years was 91.5% (95% confidence interval, 82.1% to 100%). The findings of this short-term retrospective study indicate that posterior MZRs are a therapeutic option for certain patients. In addition, several clinical procedures contribute to MZR success, including preparation design and occlusal and adhesive surface treatments.
Statins are cholesterol-lowering drugs that have been reported to promote bone formation. The purpose of this study was to investigate the effect of simvastatin on the enhancement of bone formation around titanium implants. Thirty-week-old female rats received pure titanium implants in both tibiae. The animals were intra-peritoneally administered 0, 0.125, 1, 5 or 10 mg kg(-1) of simvastatin daily. After 30 days, the animals were sacrificed, and specimens were prepared. The bone contact ratio of the implant, bone density in the medullary canal and percentage of cortical bone were obtained. Markers for bone turnover were also measured using sera collected at the time of euthanasia. In the medullary canal, a scanty amount of bone was observed in the 0, 0.125 and 1 mg kg(-1) groups. In contrast, in both the 5 and 10 mg kg(-1) groups, thicker bone trabeculae were abundant. Histometric observations showed that the bone contact ratio and the bone density of both groups were significantly greater than those of the other groups (anova, P < 0.01). However, no significant difference in the percentage of cortical bone was found between groups. Serum chemistry showed that statin increased bone formation markers and decreased bone resorption markers. In conclusion, although the dose equivalent to that used in human patients with hypercholesterolemia was not effective, a simvastatin dose of 5 mg kg(-1) or higher increased medullary bone formation around the titanium. In contrast, no effect of simvastatin on pre-existing cortical bone was indicated.
BackgroundThere are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant–abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw.MethodsWe observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems.ResultsDuring the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant–abutment connection indicated that microleakage generally increased as loading procedure progressed.The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation.ConclusionsWithin the limitation of the present study, CC was stable even after the loading in the RTV of abutment screw and it prevented microleakage from the microgap between the implant body and the abutment, among the three tested connections.
The purpose of this study was to investigate the effects of implant position and loading position on biomechanical behaviors using implant-supported removable partial denture (ISRPD) models in a simulated Kennedy class Ⅱ partially edentulous mandible. Three types of Kennedy class Ⅱ mandibular acrylic resin models (a conventional RPD without support by an implant—CRPD; models with an implant placed at first molar (#46)—MP-ISRPD— and second molar (#47)—DP-ISRPD) were used to measure vertical displacement of the RPD, mesio-distal displacement of the abutment tooth, and bending moment of the abutment tooth and implant under one-point loading. The variables at three respective loading points (#45, #46 and #47) were compared statistically. Vertical displacement was suppressed in ISRPDs compared to the CRPD, and significant effects were identified under loading at the implant position. The largest meiso-distal displacement was observed in MP-ISRPD under #47 loading. Bending moments of the abutment tooth and implant were significantly higher in MP-ISRPD than in DP-ISPRD. In MP-ISRPD, a higher bending moment of the abutment tooth under #45 and #47 loading was detected, although the bending moment in DP-ISRPD was almost zero. The results of this study suggested that MP-ISRPD shows the specific biomechanical behaviors, although DP-ISRPD might provide biomechanical benefits under all one-point loading conditions.
Obtained results suggest that the primary stability of implants could be quantitatively estimated using the CT value preoperatively, indicating the CT value of bone surrounding an implant can contribute considerably to implant planning and design choice in clinical situations.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.