Objective: We performed a systematic review and meta-analysis of studies that assessed the performance of body mass index (BMI) to detect body adiposity. Design: Data sources were MEDLINE, EMBASE, Cochrane, Database of Systematic Reviews, Cochrane CENTRAL, Web of Science, and SCOPUS. To be included, studies must have assessed the performance of BMI to measure body adiposity, provided standard values of diagnostic performance, and used a body composition technique as the reference standard for body fat percent (BF%) measurement. We obtained pooled summary statistics for sensitivity, specificity, positive and negative likelihood ratios (LRs), and diagnostic odds ratio (DOR). The inconsistency statistic (I2) assessed potential heterogeneity. Results: The search strategy yielded 3341 potentially relevant abstracts, and 25 articles met our predefined inclusion criteria. These studies evaluated 32 different samples totaling 31 968 patients. Commonly used BMI cutoffs to diagnose obesity showed a pooled sensitivity to detect high adiposity of 0.50 (95% confidence interval (CI): 0.43-0.57) and a pooled specificity of 0.90 (CI: 0.86-0.94). Positive LR was 5.88 (CI: 4.24-8.15), I 2 ¼ 97.8%; the negative LR was 0.43 (CI: 0.37-0.50), I 2 ¼ 98.5%; and the DOR was 17.91 (CI: 12.56-25.53), I 2 ¼ 91.7%. Analysis of studies that used BMI cutoffs X30 had a pooled sensitivity of 0.42 (CI: 0.31-0.43) and a pooled specificity of 0.97 (CI: 0.96-0.97). Cutoff values and regional origin of the studies can only partially explain the heterogeneity seen in pooled DOR estimates. Conclusion: Commonly used BMI cutoff values to diagnose obesity have high specificity, but low sensitivity to identify adiposity, as they fail to identify half of the people with excess BF%.
BMI has high specificity but low sensitivity to detect excess adiposity and fails to identify over a quarter of children with excess body fat percentage.
Dysfunction of different components within continuous-flow (CF) left ventricular assist device (LVAD) systems may cause adverse cardiovascular and end-organ sequelae. Outflow graft obstruction is a recognized type of LVAD component dysfunction. Ten patients were admitted and treated for LVAD outflow graft obstruction. Two of these patients subsequently developed recurrent outflow graft obstruction requiring reintervention; however, each reoccurrence was at a different site than the original obstruction. Thus, a total of 12 cases of obstruction were analyzed. The most common reasons for hospital admission were low flow LVAD alarms or decompensated heart failure. Presentation with outflow graft obstruction occurred an average of 3.0 years after LVAD implantation. Patients underwent echocardiographic evaluation at the time of admission. Left ventricular assist device component dysfunction was suspected based on echocardiographic findings, and follow-up contrast studies were used to establish the specific diagnosis of outflow graft stenosis. The majority of stenotic lesions (10/12) were treated percutaneously with balloon angioplasty and stenting with balloon-expandable endovascular prostheses. Postintervention, all patients had significant improvement in LVAD flow rates.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.