Aim: The International Continence Society (ICS) has standardized quality control and interpretation of uroflowmetry and urodynamics. We evaluated traces from two large studies of male lower urinary tract symptoms (UPSTREAM and UNBLOCS) against ICS standards of urodynamic equipment and practice. Methods: Ten percent of uroflowmetry and urodynamics traces were selected at random from hospital sites. A data capture template was designed from the ICS Fundamentals of Urodynamic Practice checklist. Two pretrained blinded assessors extracted the data, with a third assessor to arbitrate. Departmental records of calibration checks and equipment maintenance were scrutinized. Results: Seven out of twenty-five (28%) departments reported no calibration checks. Four sites (16%) could not provide annual service records. In 32 out of 296 (10.8%) uroflowmetry traces, findings were affected by artifact. One hundred ten urodynamic study traces were reviewed; in 11 records (10%), key pressure traces were incompletely displayed. In 30 (27.2%), reference zero was not set to atmospheric pressure. Resting pressures were outside the expected range for 36 (32.7%). Pressure drift was seen in 18 traces (16.4%). At pressureflow study commencement, permission to void was omitted in 15 (13.6%).Cough testing after voiding was done in 71.2%, but the resulting cough spikes were significantly different in 16.5%. Erroneous diagnosis of bladder outlet obstruction (BOO) was identified in six cases (5.5%).Conclusions: Erroneous diagnosis of BOO is a serious error of interpretation, as it could lead to unnecessary surgery. Other errors of standardization, testing, and interpretation were identified with lower risk of adverse implications. ---This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.