Rapid detection of microorganisms in respiratory specimens is of paramount importance to drive the proper antibiotic regimen to prevent complications and transmission of infections. In the present study, the respiFISH® HAP Gram (-) Panel (miacom diagnostics GmbH, Duesseldorf, Germany) for the etiological diagnosis of hospital-acquired pneumonia was compared with the traditional culture method for the detection of major Gram-negative pathogens in respiratory specimens. respiFISH® combined the classical fluorescence in situ hybridization (FISH) technology with fluorescence-labeled DNA molecular beacons as probes. From September 2011 to January 2012, 165 samples were analyzed: the sensitivity and specificity were 94.39 and 87.93%, respectively. Only six pathogens (3.6%) were not identified with respiFISH®, while seven specimens (3%) provided false-positive results. This beacon-based identification shortens the time to result by at least one work day, providing species-level identification within half an hour. Considering the high sensitivity and specificity and the significant time saving, the introduction of bbFISH® assays could effectively complement traditional systems in microbiology laboratories.
BackgroundDiagnosis and treatment of bloodstream infections (BSI) are often hampered by the delay in obtaining the final results of blood cultures. Rapid identification of pathogens involved in BSI is of great importance in order to improve survival of septic patients. Beacon-based fluorescent in situ hybridization (hemoFISH® Gram positive and hemoFISH® Gram negative test kits, miacom diagnostics GmbH Düsseldorf, Germany) accelerates the identification of most frequent bacterial pathogens of sepsis.ResultsIn this study a total of 558 blood culture (377 blood culture positive and 181 negative) were tested with the hemoFISH® method and the results were evaluated in comparison with the traditional culture based methods. The overall sensitivity and specificity of the hemoFISH® tests were 94.16% and 100%, while, the PPV and NPV were 100 and 89.16%, respectively. As the hemoFISH® results were obtained within 45 mins, the time difference between the final results of the traditional culture method and the hemoFISH® assay was about two days.ConclusionsConsidering the good sensitivity and specificity of the hemoFISH® assays as well as the significant time saving in obtaining the final results (p-value 0.0001), the introduction of the system could be rialable in the microbiology laboratories, even alongside the traditional systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.