The content of these European Society of Cardiology (ESC) Guidelines has been published for personal and educational use only. No commercial use is authorized. No part of the ESC Guidelines may be translated or reproduced in any form without written permission from the ESC. Permission can be obtained upon submission of a written request to Oxford University Press, the publisher of the European Heart Journal and the party authorized to handle such permissions on behalf of the ESC (
Aims The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter-Defibrillators (EU-CERT-ICD), a prospective investigator-initiated, controlled cohort study, was conducted in 44 centres and 15 European countries. It aimed to assess current clinical effectiveness of primary prevention ICD therapy. Methods and results We recruited 2327 patients with ischaemic cardiomyopathy (ICM) or dilated cardiomyopathy (DCM) and guideline indications for prophylactic ICD implantation. Primary endpoint was all-cause mortality. Clinical characteristics, medications, resting, and 12-lead Holter electrocardiograms (ECGs) were documented at enrolment baseline. Baseline and follow-up (FU) data from 2247 patients were analysable, 1516 patients before first ICD implantation (ICD group) and 731 patients without ICD serving as controls. Multivariable models and propensity scoring for adjustment were used to compare the two groups for mortality. During mean FU of 2.4 ± 1.1 years, 342 deaths occurred (6.3%/years annualized mortality, 5.6%/years in the ICD group vs. 9.2%/years in controls), favouring ICD treatment [unadjusted hazard ratio (HR) 0.682, 95% confidence interval (CI) 0.537–0.865, P = 0.0016]. Multivariable mortality predictors included age, left ventricular ejection fraction (LVEF), New York Heart Association class <III, and chronic obstructive pulmonary disease. Adjusted mortality associated with ICD vs. control was 27% lower (HR 0.731, 95% CI 0.569–0.938, P = 0.0140). Subgroup analyses indicated no ICD benefit in diabetics (adjusted HR = 0.945, P = 0.7797, P for interaction = 0.0887) or those aged ≥75 years (adjusted HR 1.063, P = 0.8206, P for interaction = 0.0902). Conclusion In contemporary ICM/DCM patients (LVEF ≤35%, narrow QRS), primary prophylactic ICD treatment was associated with a 27% lower mortality after adjustment. There appear to be patients with less survival advantage, such as older patients or diabetics.
AimsTherapy with an implantable cardioverter defibrillator (ICD) is established for the prevention of sudden cardiac death (SCD) in high risk patients. We aimed to determine the effectiveness of primary prevention ICD therapy by analysing registry data from 14 centres in 11 European countries compiled between 2002 and 2014, with emphasis on outcomes in women who have been underrepresented in all trials.Methods and resultsRetrospective data of 14 local registries of primary prevention ICD implantations between 2002 and 2014 were compiled in a central database. Predefined primary outcome measures were overall mortality and first appropriate and first inappropriate shocks. A multivariable model enforcing a common hazard ratio for sex category across the centres, but allowing for centre-specific baseline hazards and centre specific effects of other covariates, was adjusted for age, the presence of ischaemic cardiomyopathy or a CRT-D, and left ventricular ejection fraction ≤25%. Of the 5033 patients, 957 (19%) were women. During a median follow-up of 33 months (IQR 16–55 months) 129 women (13%) and 807 men (20%) died (HR 0.65; 95% CI: [0.53, 0.79], P-value < 0.0001). An appropriate ICD shock occurred in 66 women (8%) and 514 men (14%; HR 0.61; 95% CI: 0.47–0.79; P = 0.0002).ConclusionOur retrospective analysis of 14 local registries in 11 European countries demonstrates that fewer women than men undergo ICD implantation for primary prevention. After multivariate adjustment, women have a significantly lower mortality and receive fewer appropriate ICD shocks.
The aim of this European Heart Rhythm Association (EHRA) survey was to assess the utilization of same-day discharge (SDD) in electrophysiology (EP). An online-based questionnaire was shared with the EHRA community between 12 and 30 June 2020 and recorded institutional information, complication assessment, recent experiences, and opinions regarding possible advantages or concerns with SDD. In total, 218 responses from 49 countries provided information on current SDD management. Overall, SDD was implemented in 77.5%, whereas this proportion was significantly higher in tertiary and high-volume centres (83.8% and 85.3%, both P < 0.01). The concept of SDD was most commonly used following implantations of cardiac event recorders (97%), diagnostic EP procedures (72.2%), and implantations of pacemakers with one or two intracardiac leads (50%), while the lowest SDD utilization was observed after catheter ablations of left atrial or ventricular arrhythmias. Within SDD-experienced centres, ∼90% respondents stated that this discharge concept is recommendable or highly recommendable and reported that rates of increased rehospitalization and complication rates were low. Most respondents assumed a better utilization of hospital resources (78.2%), better cost effectiveness (77.3%), and an improved patients’ comfort but were concerned about possible impairment of detection (72.5%) and management (78.7%) of late complications. In conclusion, >75% of respondents already implement SDD following EP interventions with a large heterogeneity with regard to specific procedures. Further research is needed to confirm or disprove existing and expected benefits and obstacles.
In malignant tumors including uveal melanoma there is a continuous effort in search for additional and relevant factors with predictive value and possible therapeutic indications. In the present work we evaluated the 5-year mortality in a group of patients with surgically treated uveal melanoma and its relation to selected demographic, clinical and histopathological parameters, including the expression of apoptosis inducing factor (AIF) in the neoplastic tissue.We analyzed retrospectively the clinical data of patients with uveal melanoma treated surgically (enucleation, endoresection, exenteration) in the period from 2001 to 2007 (n=54). Immunohistochemical detection of AIF expression in formalin fixed and in paraffin embedded tissue samples was evaluated semiquantitatively, intensity and percentage multiplicative Quick Score (QS) was calculated and compared between patients with over 5 year (n=32) and less than 5 year (n=22) survival. In the analyzed group of 54 patients the 5 year mortality was 41 %. We confirmed the negative prognostic significance of some of the known prognostic factors as the tumor size and volume, T3 and T4 stage in the TNM classification and the mixed histological type of the tumor. Immunohistochemistry performed on 49 melanoma specimens showed AIF cytoplasmic positivity, no nuclear translocation was detected. The cut-off value of AIF expression QS ≥ 4 (18) in tumor cells separated the 5 year survival of patients (P = 0.018), odds ratio 5.2 (1.24 - 21.73). Moderate and strong expression of AIF in tumor cells also correlated with less favorable prognosis. Confocal microscopy proved colocalization of AIF with mitochondrial marker in neoplastic cells.The prognosis of patients with uveal melanoma can be more accurate with inclusion of immunohistochemical detection of AIF expression. Increased expression of the AIF protein appears as a new negative prognostic factor predicting the 5 year survival.
Data on reprocessing of electrophysiology (EP) materials are sparse. Reprocessing of catheters and other materials in daily routine varies through countries and may depend on specific material characteristics, supplier, or federal law. The aim of this study was to collect data on reprocessing usage through EHRA countries. An online survey consisting of 27 questions was distributed to EHRA Young EP members and members of national EP working groups. Two hundred and two participants from 34 EHRA countries completed the survey. One hundred and seven respondents (53.0%) reported having used and using reprocessed EP material, 30 (14.9%) respondents have used reprocessed EP material in the past but not at the time of the survey, 65 (32.2%) had never used reprocessed EP material. The most reprocessed EP materials include cables (70%), diagnostic EP catheters with deflectable (64%) or fixed curve (63%), non-irrigated ablation catheters (51%), and other conventional diagnostic catheters (41%). The most durable material was diagnostic EP catheters with a fixed curve (61%), the most sensitive material was ablation catheters with contact force sensors (21%). Important benefits were seen in reducing costs for the providing hospital (65%) and the healthcare provider (42%) and making EP procedures available for a greater number of patients (42%). Main concerns were on quality aspects (58%), contamination (52%), and loss of precision (47%). Reprocessing of EP materials is heterogeneously managed among EHRA countries. The present survey shows that European electrophysiologists consider the use of reprocessed EP material as generally safe and cost-effective.
OBJECTIVE Diabetes increases the risk of all-cause mortality and sudden cardiac death (SCD). The exact mechanisms leading to sudden death in diabetes are not well known. We compared the incidence of appropriate shocks and mortality in patients with versus without diabetes with a prophylactic implantable cardioverter defibrillator (ICD) included in the retrospective EU-CERT-ICD registry. RESEARCH DESIGN AND METHODS AND RESULTS A total of 3,535 patients from 12 European EU-CERT-ICD centers with a mean age of 63.7 ± 11.2 years (82% males) at the time of ICD implantation were included in the analysis. A total of 995 patients (28%) had a history of diabetes. All patients had an ICD implanted for primary SCD prevention. End points were appropriate shock and all-cause mortality. Mean follow-up time was 3.2 ± 2.3 years. Diabetes was associated with a lower risk of appropriate shocks (adjusted hazard ratio [HR] 0.77 [95% CI 0.62–0.96], P = 0.02). However, patients with diabetes had significantly higher mortality (adjusted HR 1.30 [95% CI 1.11–1.53], P = 0.001). CONCLUSIONS All-cause mortality is higher in patients with diabetes than in patients without diabetes with primary prophylactic ICDs. Subsequently, patients with diabetes have a lower incidence of appropriate ICD shocks, indicating that the excess mortality might not be caused primarily by ventricular tachyarrhythmias. These findings suggest a limitation of the potential of prophylactic ICD therapy to improve survival in patients with diabetes with impaired left ventricular function.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.