Background Intracerebral hemorrhage (ICH) accounted for 9% to 27% of all strokes worldwide in the last decade, with high early case fatality and poor functional outcome. In view of recent randomized controlled trials (RCTs) of the management of ICH, the European Stroke Organisation (ESO) has updated its evidence-based guidelines for the management of ICH. Method A multidisciplinary writing committee of 24 researchers from 11 European countries identified 20 questions relating to ICH management and created recommendations based on the evidence in RCTs using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach. Results We found moderate-to high-quality evidence to support strong recommendations for managing patients with acute ICH on an acute stroke unit, avoiding hemostatic therapy for acute ICH not associated with antithrombotic drug use, avoiding graduated compression stockings, using intermittent pneumatic compression in immobile patients, and using blood pressure lowering for secondary prevention. We found moderate-quality evidence to support weak recommendations for intensive lowering of systolic blood pressure to <140 mmHg within six-hours of ICH onset, early surgery for patients with a Glasgow Coma Scale score 9-12, and avoidance of corticosteroids. Conclusion These guidelines inform the management of ICH based on evidence for the effects of treatments in RCTs. Outcome after ICH remains poor, prioritizing further RCTs of interventions to improve outcome.
Background and Purpose-Functioning and disability after ischemic stroke are clinically meaningful and of major relevance to patients. Despite many instruments available to assess these outcomes, little is known about their interrelation and predictive factors. Methods-We prospectively identified 4264 patients with acute ischemic stroke from 30 hospitals in Germany during a 1-year period between 1998 and 1999 and registered them in a common data bank. The patients were centrally followed up via telephone interview after 100 days and 1 year to assess various scales such as the Barthel Index (BI), modified Rankin Scale (MRS), extended Barthel Index (EBI), Short Form-36 Physical Functioning (SF-36 PF), and Center for Epidemiologic Studies-Depression short form (CES-D). Results-Outcome status could be assessed in 67.2% of patients 100 days after hospital admission. Of these, 13.9% had died, 53.7% had regained functional independence (BI Ͻ95), 46.3% had no or mild residual symptoms (MRS Յ1), and 44.6% had no higher cognitive deficits on the EBI. Of the patients who personally answered the follow-up questions, 67% had no major physical disability (SF-36 PF Ͻ60), and 32.9% reported symptoms classified as depression (CES-D Ն10). The high percentage of patients reaching the maximum score (ceiling effect) in the BI was less pronounced in the MRS and SF-36 PF. The predictive factors for dichotomized outcomes on each scale were similar for adverse functioning and disability but varied considerably for depression. Conclusions-To avoid ceiling effects in outcome distribution of patients treated in specialized stroke centers, the MRS and SF-36 PF instruments are preferable to the BI. Parametric use of the SF-36 PF could further improve outcome measurement by considering individual treatment effects.
Background and Purpose— There is no consensus about indicators for measuring quality of acute stroke care in Germany. Therefore, a standardized process was initiated recently to develop and implement evidence-based indicators for the measurement of quality of acute hospital stroke care. Methods— Quality indicators were developed by a multidisciplinary board between November 2003 and December 2005. The process was initiated by the German Stroke Registers Study Group in cooperation with the German Stroke Society, the German Society of Neurology, the German Stroke Foundation, Regional Offices for Quality Assurance and other experts proven in the field. National and international recommendations were considered during the development process. The process was based on a systematic literature review, an independent external evaluation of the process and its results, and a prospective pilot study to evaluate the defined indicators in clinical practice. Results— Overall a set of 24 indicators was developed to measure performance of acute care hospitals in the 3 health care dimensions structure, process and outcome as well as in 3 treatment phases prehospital, in-hospital/acute and postacute. Practicability of the derived indicators was tested in a prospective pilot study. During a 2-month period, 1006 patients in 13 hospitals were documented. Application of the new indicator set was found to be feasible by participating physicians and hospitals. Median time to document the required information for 1 patient was 5 minutes. Nationwide implementation of the new indicator set within regional registers in Germany started since April 2006. Conclusions— The development of indicators to measure hospital performance in stroke care is an important step toward improving stroke care on a national level. The chosen standardized evidence-based approach ensures maximal transparency, acceptance and sustainability of the developed indicators in Germany.
Background: Subjective risk factor perception is an important component of the motivation to change unhealthy life styles. While prior studies assessed cardiovascular risk factor knowledge, little is known about determinants of the individual perception of stroke risk.
The aim of this study was to investigate the safety and performance of the second generation of an implantable intraocular pressure (IOP) sensor in patients with primary open angle glaucoma (POAG).DESIGN: prospective, noncomparative, open-label, multicenter clinical investigation.METHODS: In this study, patients with POAG, regularly scheduled for cataract surgery, were implanted with a ring-shaped, sulcus-placed, foldable IOP sensor in a single procedure after intraocular lens implantation. Surgical complications as well as adverse events (AEs) during 12 months of follow-up were recorded. At each follow-up visit, a complete ophthalmic examination, including visual acuity, IOP, slit lamp examination, and dilated funduscopy as well as comparative measurements between Goldmann applanation tonometry and the EYEMATE-IO implant were performed.RESULTS: The EYEMATE-IO implant was successfully implanted in 22 patients with few surgical complications and no unexpected device-related AEs. All ocular AEs resolved quickly under appropriate treatment. Comparative measurements showed good agreement between EYEMATE-IO and Goldmann applanation tonometry (GAT) with an intraclass correlation coefficient (ICC(3,k)) of 0.783 (95% confidence interval [CI]: 0.743, 0.817). EYEMATE-IO measurements were higher than GAT, with a mean difference of 3.2 mm Hg (95% CI: 2.8, 3.5 mm Hg).CONCLUSIONS: The EYEMATE-IO sensor was safely implanted in 22 patients and performed reliably until the end of follow-up. This device allows for continual and long-term measurements of IOP.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.