Purpose Surface guided radiotherapy (SGRT) is reported as a feasible setup technique for whole‐breast radiotherapy in deep inspiration breath hold (DIBH), but position errors of bony structures related to deeper parts of the target are not fully known. The aim of this study was to estimate patient setup accuracy and margins obtained with two different SGRT workflows with and without daily kV‐ and/or MV‐based image guidance (IGRT). Methods A total of 50 breast cancer patients were treated in DIBH, using SGRT for the patient setup, and IGRT for isocenter corrections. The patients were treated at two different departments, one using AlignRT® (25 patients) and the other using Catalyst™ (25 patients). Inter‐fractional position errors were analyzed retrospectively in orthogonal and tangential setup images, and analyzed with and without IGRT. Results In the orthogonal kV‐kV images, the systematic residual errors of the bony structures were ≤ 3 mm in both groups with SGRT‐only. When fine‐adjusted by daily IGRT, the errors decreased to ≤ 2 mm; except for the shoulder joint. The residual errors of the ribs in tangential images were between 1 and 2 mm with both workflows. The heart planning margins were between 3 and 7 mm. Conclusions The frequency of IGRT may be considerably reduced with a well‐planned SGRT‐workflow for whole‐breast DIBH with residual errors ≤ 3 mm. This accuracy can be further improved with an IGRT scheme.
AimTraditional radiotherapy treatment techniques of the breast are insensitive for deformations and swelling of the soft tissue. The purpose of this study was to evaluate the dose changes seen with tissue deformations using different image matching methods when VMAT technique was used, and compare these with tangential technique.MethodsThe study included 24 patients with breast or chest wall irradiations, nine of whom were bilateral. In addition to planar kV setup imaging, patients underwent weekly cone‐beam computed tomography (CBCT) imaging to evaluate soft tissue deformations. The effect of the deformations was evaluated on VMAT plans optimized with 5‐mm virtual bolus to create skin flash, and compared to standard tangential plans with 2.5 cm skin flash. Isocenter positioning using 2D imaging and CBCT were compared.ResultsWith postural changes and soft tissue deformations, the target coverage decreased more in the VMAT plans than in the tangential plans. The planned V90% coverage was 98.3% and 99.0% in the tangential and VMAT plans, respectively. When tattoo‐based setup and online 2D match were used, the coverage decreased to 97.9% in tangential and 96.5% in VMAT plans (P < 0.001). With automatic CBCT‐based image match the respective coverages were 98.3% and 98.8%. In the cases of large soft tissue deformations, the replanning was needed for the VMAT plan, whereas the tangential plan still covered the whole target volume.ConclusionsThe skin flash created using an optimization bolus for VMAT plans was in most cases enough to take into account the soft tissue deformations seen in breast VMAT treatments. However, in some cases larger skin flash or replanning were needed. The use of 2D match decreased the target coverage for VMAT plans but not for FinF plans when compared to 3D match. The use of CBCT match is recommended when treating breast/chest wall patients with VMAT technique.
Background: Adjuvant radiotherapy (RT) of left-sided breast cancer (LSBC) with voluntary deep inspiration breath hold (vDIBH) technique reduces the cardiac dose. In this study, the effect of marker block position and the efficacy of breath hold level (BHL) correction based on lateral kV setup images are evaluated to improve the daily reproducibility. Material and methods: A total of 148 consecutive LSBC patients treated with vDIBH RT were included in this study. The real-time position management (RPM) marker block was placed on the abdominal wall in 63 patients (group A) and on the sternum in 85 patients (group S). Acquired 900 (group A) þ 1040 (group S) orthogonal image pairs were retrospectively analyzed. The actual BHL was determined from the lateral kV images. The height of the BHL gating window in RPM was corrected if errors of the actual BHL exceeded 4 mm. Setup margins were calculated for the chest wall and for bony surrogates of the lymph node regions. Results: The sternal marker block reduced the random residual errors in the actual BHL (p < 0.05). The BHL correction was required for 26/63 patients in group A and for 26/85 patients in group S. Correction of the BHL window significantly reduced both the systematic and the random residual error in both groups. In patients with lymph node irradiation, the effect of both marker placement and BHL window correction was significant in the superior-inferior direction. Correction of the BHL reduced the mean cardiac dose by 0.5 Gy (p < 0.01) in group A and 0.6 Gy (p < 0.05) in group S. Conclusions: Reproducibility of the BHL can be improved by placing the marker block on the sternum and correcting the height of the BHL window based on lateral kV setup images. Acquisition of lateral kV images in the first 3 fractions and once a week during RT is recommended.
BackgroundAdjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins.Methods1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated.ResultsFor the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients.ConclusionsThe smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.
BackgroundWe estimated sufficient setup margins for head-and-neck cancer (HNC) radiotherapy (RT) when 2D kV images are utilized for routine patient setup verification. As another goal we estimated a threshold for the displacements of the most important bony landmarks related to the target volumes requiring immediate attention.MethodsWe analyzed 1491 orthogonal x-ray images utilized in RT treatment guidance for 80 HNC patients. We estimated overall setup errors and errors for four subregions to account for patient rotation and deformation: the vertebrae C1-2, C5-7, the occiput bone and the mandible. Setup margins were estimated for two 2D image guidance protocols: i) imaging at first three fractions and weekly thereafter and ii) daily imaging. Two 2D image matching principles were investigated: i) to the vertebrae in the middle of planning target volume (PTV) (MID_PTV) and ii) minimizing maximal position error for the four subregions (MIN_MAX). The threshold for the position errors was calculated with two previously unpublished methods based on the van Herk’s formula and clinical data by retaining a margin of 5 mm sufficient for each subregion.ResultsSufficient setup margins to compensate the displacements of the subregions were approximately two times larger than were needed to compensate setup errors for rigid target. Adequate margins varied from 2.7 mm to 9.6 mm depending on the subregions related to the target, applied image guidance protocol and early correction of clinically important systematic 3D displacements of the subregions exceeding 4 mm. The MIN_MAX match resulted in smaller margins but caused an overall shift of 2.5 mm for the target center. Margins ≤ 5mm were sufficient with the MID_PTV match only through application of daily 2D imaging and the threshold of 4 mm to correct systematic displacement of a subregion.ConclusionsAdequate setup margins depend remarkably on the subregions related to the target volume. When the systematic 3D displacement of a subregion exceeds 4 mm, it is optimal to correct patient immobilization first. If this is not successful, adaptive replanning should be considered to retain sufficiently small margins.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.