Visualization and scaling of drop-on-demand and continuous-jet fluid atomization of water are presented to elucidate the fluid physics of the ejection process and characterize the modes of operation of a novel micromachined ultrasonic droplet generator. The device comprises a fluid reservoir that is formed between a bulk ceramic piezoelectric transducer and an array of liquid horn structures wet etched into (100) silicon. At resonance, the transducer generates a standing ultrasonic pressure wave within the cavity and the wave is focused at the tip of the nozzle by the horn structure. Device operation has been demonstrated by water droplet ejection from 5to10μm orifices at multiple resonant frequencies between 1 and 5MHz. The intimate interactions between focused ultrasonic pressure waves and capillary waves formed at the liquid–air interface located at the nozzle tip are found to govern the ejection dynamics, leading to different ejection modalities ranging from individual droplets to continuous jet. Specifically, we report the results of high-resolution stroboscopic optical imaging of the liquid–air interface evolution during acoustic pumping to elucidate the role of capillary waves in the droplet formation and ejection process. A basic understanding of the governing physics gained through careful visualization and scaling forms the basis for development of improved theoretical models for the droplet formation and ejection processes by accounting for key fluid mechanical features of the phenomena.
The analytical characterization of a novel ion source for mass spectrometry named Array of Micromachined UltraSonic Electrosprays (AMUSE) is presented here. This is a fundamentally different type of ion generation device, consisting of three major components: 1) a piezoelectric transducer that creates ultrasonic waves at one of the resonant frequencies of the sample-filled device, 2) an array of pyramidally-shaped nozzles micromachined on a silicon wafer, and 3) a spacer which prevents contact between the array and transducer ensuring the transfer of acoustic energy to the sample. A high pressure gradient generated at the apices of the nozzle pyramids forces the periodic ejection of multiple droplet streams from the device. With this device, the processes of droplet formation and droplet charging are separated, hence, the limitations of conventional electrospraytype ion sources, including the need for high charging potentials and the addition of organic solvent to decrease surface tension can be avoided. In this work, a Venturi device is coupled with AMUSE in order to increase desolvation, droplet focusing, and signal stability. Results show that ionization of model peptides and small tuning molecules is possible with DC charging potentials of 100 V DC or less. Ionization in RF-only mode (without DC biasing) was also possible. It was observed that, when combined with AMUSE, the Venturi device provides a 10-fold gain in signal-to-noise ratio for 90% aqueous sample solutions. Further reduction in the diameter of the orifices of the micromachined arrays, led to an additional signal gain of at least 3 orders of magnitude, a 2-to 10-fold gain in the signal-to-noise ratio, and an improvement in signal stability from 47% to 8.5% RSD. The effectiveness of this device for the soft ionization of model proteins in aqueous media, such as cytochrome C was also examined, yielding spectra with an average charge state of 8.8 when analyzed with a 100 V DC charging potential. Ionization of model proteins was also possible in RF-only mode.
We report on development and experimental characterization of a novel cell manipulation device-the electrosonic ejector microarray-which establishes a pathway for drug and/or gene delivery with control of biophysical action on the length scale of an individual cell. The device comprises a piezoelectric transducer for ultrasound wave generation, a reservoir for storing the sample mixture and a set of acoustic horn structures that form a nozzle array for focused application of mechanical energy. The nozzles are micromachined in silicon or plastic using simple and economical batch fabrication processes. When the device is driven at a particular resonant frequency of the acoustic horn structures, the sample mixture of cells and desired transfection agents/molecules suspended in culture medium is ejected from orifices located at the nozzle tips. During sample ejection, focused mechanical forces (pressure and shear) are generated on a microsecond time scale (dictated by nozzle size/geometry and ejection velocity) resulting in identical "active" microenvironments for each ejected cell. This process enables a number of cellular bioeffects, from uptake of small molecules and gene delivery/transfection to cell lysis. Specifically, we demonstrate successful calcein uptake and transfection of DNA plasmid encoding green fluorescent protein (GFP) into human malignant glioma cells (cell line LN443) using electrosonic microarrays with 36, 45 and 50 mum diameter nozzle orifices and operating at ultrasound frequencies between 0.91 and 0.98 MHz. Our results suggest that efficacy and the extent of bioeffects are mainly controlled by nozzle orifice size and the localized intensity of the applied acoustic field.
Chemical warfare agents (CWA) can be absorbed by variety of materials including polymeric coatings like paints through bulk liquid contact, thus presenting touch and vapor hazards to interacting personnel. In order for accurate hazard assessments and subsequent decontamination approaches to be designed, it is necessary to characterize the absorption and distribution of highly toxic species, as well as their chemical simulant analogs, in the subsurface of engineered, heterogeneous materials. Using a combination of judicious sample preparation in concert with scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS), it should be possible to directly measure the uptake and distribution of CWA simulants in the subsurface of complex multilayer coatings. Polyurethane and alkyd coatings were applied to aluminum and silicon substrates and contaminated with 2-chloroethyl ethyl sulfide (CEES) and dimethyl methylphosphonate (DMMP). The surfaces and cross-sectional interfaces of the contaminated coatings were probed with SEM-EDS to provide imaging, spectral, and elemental mapping data of the contaminant-material systems. This work demonstrated SEM-EDS capability to detect and spatially resolve unique elemental signatures of CWA simulants within military coatings. The visual and quantitative results provided by these direct measurements illustrate contaminant spatial distributions, provide order-of-magnitude approximations for diffusion coefficients, and reveal material characteristics that may impact contaminant transport into complex coating materials. It was found that contaminant uptake was significantly different between the topcoat and primer layers.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.