Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.
Despite the fact that both methods yielded similar results and have statistically similar number of complications, the type of postoperative complications was different between groups. The plate group had more postoperative pain and worse function but both aspects improved after plate removal. The rope group had more complex complications including deep infection and recurrence of deformity and fracture. These differences should be taken into consideration when consenting the patient regarding possible treatment.
Acquisition of arthroscopic skills is not always easy and can be time-consuming. Simulation in arthroscopy improves surgical skills and can bridge the gap between reduced surgical exposure and training time and the need to reach a required level of competency. We propose a method to create a simple and cost-effective arthroscopic skills simulator using readily available materials and a low-cost Web camera available from online shops. This arthroscopic simulation device can be used to improve skills of all levels of trainees at home, in a bioskills laboratory, or in the theater. It can also be used by experienced surgeons to train with instruments and devices before using them for the first time in theaters, thus ensuring safe use and improving patient safety. Further validation as a training tool is needed and should be the focus of additional research, but early results are very promising.
A 69-year-old man presented with sudden onset of pain with acute tense swelling of his left leg. Initially he was treated empirically with antibiotics for cellulitis while the possibility of deep vein thrombosis was ruled out. His symptoms gradually worsened with progressive distal neurological deficit and increasing pain. Further investigations suggested that he had a ruptured Baker's cyst in the calf with development of compartment syndrome.
The authors report a case of pseudoaneurysm of the profunda femoris artery following fixation of an intertrochanteric hip fracture with a dynamic hip screw. Diagnosis and treatment of this rare complication are described.
Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation.
Traditionally, anterior cruciate ligament (ACL) injuries have been difficult to diagnose in the Casualty Department. Studies have shown that the anterior drawer test has a poor sensitivity both in acute and chronic ACL deficient knees [4, 6, 9]; thus, more emphasis has been placed on the pivot shift and Lachman tests [3]. We report four cases of proven ACL rupture where clinical examination revealed an absent pivot shift and a near normal Lachman test following a displaced bucket handle tear of the medial meniscus. This finding has been reproduced in cadaver studies, and we conclude that if the history strongly suggests an ACL injury and examination reveals a stable knee, then the dual pathology of medial meniscus tear and ACL rupture should be suspected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.